A Technique for Collision Block of Peripheral Nerve: Frequency Dependence
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A previously reported stimulation technique which elicits a unidirectionally propagated nerve action potential has been evaluated with repetition rates from 10 to 100 Hiz. Block of propagation in one direction from the stimulus site was sustained up to 50 Hz with monophasic stimulation and 30 Hz with biphasic stimulation. The use of long stimulating pulses produces pronounced degradation of the block at high frequencies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isometric force production by motor units of extensor digitorum communis muscle in man
Monster, A. W., & Chan, H. (1977) · Journal of Neurophysiology · doi:10.1152/jn.1977.40.6.1432 · Cited by 320
Cited by
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Electrical stimulation as a novel tool for regulating cell behavior in tissue engineering
Chen, C., Bai, X., Ding, Y., & Lee, I.-S. (2019) · Biomaterials Research · doi:10.1186/s40824-019-0176-8 · Cited by 444
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Self-citationSelective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Selective activation of small motor axons by quasitrapezoidal current pulses
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76383 · Cited by 222
Self-citation
Metadata
- Authors
- Van Den Honert, C., & Mortimer, J. T.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1981-05
- Volume
- BME-28
- Issue
- 5
- Pages
- 379-382
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2082796914
- Cited by
- 60
- References
- 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Technique for Collision Block of Peripheral Nerve: Frequency Dependence. https://app.cochat.ai/papers/10.1109/tbme.1981.324719
- The paper
- Van Den Honert, C., & Mortimer, J. T. (1981). A Technique for Collision Block of Peripheral Nerve: Frequency Dependence. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1981.324719
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.