The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A New Data-Reduction Algorithm for Real-Time ECG Analysis
Abstract
Typically the ECG is sampled at a rate of 200 samples/s or more, producing a large amount of data that are difficult to store, analyze, and transmit. Data-reduction algorithms that operate in real time reduce he amount of data without losing the clinical information content. They must also leave sufficient computation time available for ECG analysis. We describe here a new algorithm called CORTES that is suited for such real-time applications. This algorithm combines the best features of two other techniques called TP and AZTEC. We present the results of a study to find optimal experimental values for the controlling variables in CORTES. We compare the computations of root-mean-square reconstruction errors for a diversity of encoded ECG signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Method for the Construction of Minimum-Redundancy Codes
Huffman, D. (1952) · Proceedings of the IRE · doi:10.1109/jrproc.1952.273898 · Cited by 6,334
AZTEC, a Preprocessing Program for Real-Time ECG Rhythm Analysis
Cox, J. R., Nolle, F. M., Fozzard, H. A., & Oliver, G. C. (1968) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1968.4502549 · Cited by 367
Limited Lead Selection for Estimation of Body Surface Potential Maps in Electrocardiography
Lux, R. L., Smith, C. R., Wyatt, R. F., & Abildskov, J. A. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326332 · Cited by 216
Digital analysis of the electroencephalogram, the blood pressure wave, and the electrocardiogram
Cox, J. R., Nolle, F. M., & Arthur, R. M. (1972) · Proceedings of the IEEE · doi:10.1109/proc.1972.8877 · Cited by 128
Precision Requirements for Electrocardiographic Measurements Computed Automatically
Berson, A. S., Wojick, J. M., & Pipberger, H. V. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326146 · Cited by 13
Cited by
A patient-adaptable ECG beat classifier using a mixture of experts approach
Hu, Y. H., Palreddy, S., & Tompkins, W. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623058 · Cited by 614
Self-citationThe weighted diagnostic distortion (WDD) measure for ECG signal compression
Zigei, Y., Cohen, A., & Katz, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880093 · Cited by 405
Huang, H., Hu, S., & Sun, Y. (2019) · ACM Transactions on Cyber-Physical Systems · doi:10.1145/3341559 · Cited by 10
Metadata
- Authors
- Abenstein, J. P., & Tompkins, W. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1982-01
- Volume
- BME-29
- Issue
- 1
- Pages
- 43-48
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W1992556963
- Cited by
- 269
- References
- 5
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.