Cited by 10ECG Monitoring and AnalysisAdvanced Data Compression TechniquesSparse and Compressive Sensing Techniques

Energy-Efficient ECG Signal Compression for User Data Input in Cyber-Physical Systems by Leveraging Empirical Mode Decomposition

Huang, Hui, Hu, Shiyan, Sun, Ye·2019·ACM Transactions on Cyber-Physical Systems

Abstract

Human physiological data are naturalistic and objective user data inputs for a great number of cyber-physical systems (CPS). Electrocardiogram (ECG) as a widely used physiological golden indicator for certain human state and disease diagnosis is often used as user data input for various CPS such as medical CPS and human–machine interaction. Wireless transmission and wearable technology enable long-term continuous ECG data acquisition for human–CPS interaction; however, these emerging technologies bring challenges of storing and wireless transmitting huge amounts of ECG data, leading to energy efficiency issue of wearable sensors. ECG signal compression technique provides a promising solution for these challenges by decreasing ECG data size. In this study, we develop the first scheme of leveraging empirical mode decomposition (EMD) on ECG signals for sparse feature modeling and compression and further propose a new ECG signal compression framework based on EMD constructed feature dictionary. The proposed method features in compressing ECG signals using a very limited number of feature bases with low computation cost, which significantly improves the compression performance and energy efficiency. Our method is validated with the ECG data from MIT-BIH arrhythmia database and compared with existing methods. The results show that our method achieves the compression ratio (CR) of up to 164 with the root mean square error (RMSE) of 3.48% and the average CR of 88.08 with the RMSE of 5.66%, which is more than twice of the average CR of the state-of-the-art methods with similar recovering error rate of around 5%. For diagnostic distortion perspective, our method achieves high QRS detection performance with the sensitivity (SE) of 99.8% and the specificity (SP) of 99.6%, which shows that our ECG compression method can preserve almost all the QRS features and have no impact on the diagnosis process. In addition, the energy consumption of our method is only 30% of that of other methods when compared under the same recovering error rate.

Integrity signals

Registry

Crossref · 10.1145/3341559

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Huang, H., Hu, S., & Sun, Y.
Affiliations
Michigan Technological University (US)
Venue
ACM Transactions on Cyber-Physical Systems
Published
2019-08-09
Volume
3
Issue
4
Pages
1-19
ISSN
  • 2378-962X (ISSN-L)
  • 2378-9638
OpenAlex
W2967827507
Cited by
10
References
41
Citations by year
2026: 1 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 2
FWCI
0.92
Type
journal article
Language
en
Open access
closed
Locations
  • ACM Transactions on Cyber-Physical Systems (publishedVersion)
  • Digital Commons - Michigan Tech (Michigan Technological University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Data Compression Techniques
  • Physical Sciences › Engineering › Computational Mechanics › Sparse and Compressive Sensing Techniques
Keywords
ECG signal compression, empirical mode decomposition, energy efficiency, wearable sensors, cyber-physical systems, human-machine interaction, feature dictionary, QRS complex detection, physiological signals, wireless transmission, MIT-BIH arrhythmia database

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review