The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Driven-right-leg circuit design
Abstract
The driven-right-leg circuit is often used with biopotential differential amplifiers to reduce common mode voltage. We analyze this circuit and show that high loop gains can cause instability. We present equations that can be used to design circuits that minimize common mode voltage without instability. We also show that it is important to consider the reduction of high-frequency interference from fluorescent lights when determining the bandwidth of the drivenright-leg circuit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
Self-citation60-Hz Interference in Electrocardiography
Huhta, J. C., & Webster, J. G. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324169 · Cited by 412
Self-citationReduction of Interference Due to Common Mode Voltage in Biopotential Amplifiers
Winter, B. B., & Webster, J. G. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325167 · Cited by 166
Self-citation
Research works printed but not linked: 9
- 1977, 78213A/C Neonatal Heart Rate Module Service Manual
- weibell, 1978, susceptibility of the heart to short-duration microshock, Proc Annu Conf Eng Med Biol, 20, 111
- 1974, MAC-1 microcomputer augmented cardiograph
- 1980, Model 248J specification sheet
- 1979, 3000 Series Maintenance Manual
- reining, 1977, bandwidth consideration for the elimination of '60 hz' interference, Proc 15th Annu Meet AAMI, 203
- sterken, 1976, The evaluation of a mains-interference suppressor, 194
- 1971, Patient Safety
- 1980, Safe use of electricity in patient care areas of hospitals
Cited by
AMON: A Wearable Multiparameter Medical Monitoring and Alert System
Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., Keita, F., Schenker, E. B., Catarsi, F., Coluccini, L., et al. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837888 · Cited by 707
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441666 · Cited by 450
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
Low-Power Wearable ECG Monitoring System for Multiple-Patient Remote Monitoring
Spano, E., Di Pascoli, S., & Iannaccone, G. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2564995 · Cited by 256
Tutorial. Surface EMG detection, conditioning and pre-processing: Best practices
Merletti, R., & Cerone, G. L. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102440 · Cited by 233
Metadata
- Authors
- Winter, B. B., & Webster, J. G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1983-01
- Volume
- BME-30
- Issue
- 1
- Pages
- 62-66
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1969122934
- Cited by
- 443
- References
- 3
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Driven-right-leg circuit design. https://app.cochat.ai/papers/10.1109/tbme.1983.325168
- The paper
- Winter, B. B., & Webster, J. G. (1983). Driven-right-leg circuit design. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1983.325168
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.