The Double Magnetic Induction Method for Measuring Eye Movement - Results in Monkey and Man
The DOI matches its Crossref record.
Abstract
We describe an improved version of the double magnetic induction method for measuring eye movement, proposed by Reulen and Bakker. The idea behind the double magnetic method is to detect eye position indirectly by determining the strength of the induced secondary magnetic field of a short-circuited coil on the subject's eye caused by a primary magnetic field. A signal related to eye position is obtained from a detection coil, placed in front of the eye, without the need of connecting wires.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Object-based attention in the primary visual cortex of the macaque monkey
Roelfsema, P. R., Lamme, V. A. F., & Spekreijse, H. (1998) · Nature · doi:10.1038/26475 · Cited by 814
Two distinct modes of sensory processing observed in monkey primary visual cortex (V1)
Supèr, H., Spekreijse, H., & Lamme, V. A. F. (2001) · Nature Neuroscience · doi:10.1038/85170 · Cited by 467
Figure-ground activity in primary visual cortex is suppressed by anesthesia
Lamme, V. A. F., Zipser, K., & Spekreijse, H. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.6.3263 · Cited by 329
Masking Interrupts Figure-Ground Signals in V1
Lamme, V. A. F., Zipser, K., & Spekreijse, H. (2002) · Journal of Cognitive Neuroscience · doi:10.1162/089892902320474490 · Cited by 285
“Eye movements were monitored with scleral search coils, according to the modified double magnetic induction method ( Bour, Van Gisbergen, Bruijns, & Ottes, 1984 ).”
MethodSkewness of saccadic velocity profiles: A unifying parameter for normal and slow saccades
Van Opstal, A. J., & Van Gisbergen, J. A. M. (1987) · Vision Research · doi:10.1016/0042-6989(87)90071-x · Cited by 270
Self-citation
Metadata
- Authors
- Bour, L. J., Van Gisbergen, J. A. M., Bruijns, J., & Ottes, F. P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1984-05
- Volume
- BME-31
- Issue
- 5
- Pages
- 419-427
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2028038427
- Cited by
- 113
- References
- 0
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Double Magnetic Induction Method for Measuring Eye Movement - Results in Monkey and Man. https://app.cochat.ai/papers/10.1109/tbme.1984.325281
- The paper
- Bour, L. J., Van Gisbergen, J. A. M., Bruijns, J., & Ottes, F. P. (1984). The Double Magnetic Induction Method for Measuring Eye Movement - Results in Monkey and Man. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1984.325281
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.