CoChat

Regional Hyperthermia with an Annular Phased Array

Turner, Paul F. · 1984 · IEEE Transactions on Biomedical Engineering
Cited by 243

The DOI matches its Crossref record.

Abstract

An annular phased array electromagnetic (EM) radiating device has been developed to surround regions of the body with penetrating EM fields. This instrument uses synchronous fields to focus energy at the center of a body placed in the aperture. Methods for steering the deep heating patterns have also been demonstrated and evaluated, as well as a minimally perturbing electric field (E-field) sensor to monitor the strength of the EM fields outside the body.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1984.325376

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 243

Metadata

Authors
Turner, P. F.
Venue
IEEE Transactions on Biomedical Engineering
Published
1984-01
Volume
BME-31
Issue
1
Pages
106-114
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2005773574
Cited by
243
References
0
FWCI
26.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Regional Hyperthermia with an Annular Phased Array. https://app.cochat.ai/papers/10.1109/tbme.1984.325376
The paper
Turner, P. F. (1984). Regional Hyperthermia with an Annular Phased Array. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1984.325376

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.