Digital Filters for Real-Time ECG Signal Processing Using Microprocessors

Ahlstrom, M. L., Tompkins, W. J.·1985·IEEE Transactions on Biomedical Engineering

Abstract

Traditionally, analog circuits have been used for signal conditioning of electrocardiograms. As an alternative, algorithms implemented as programs on microprocessors can do similar filtering tasks. Also, digital filter algorithms can perform processes that are difficult or impossible using analog techniques. Presented here are a set of real-time digital filters each implemented as a subroutine. By calling these subroutines in an appropriate sequence, a user can cascade filters together to implement a desired filtering task on a single microprocessor. Included are an adaptive 60-Hz interference filter, two low-pass filters, a high-pass filter for eliminating dc offset in an ECG, an ECG data reduction algorithm, band-pass filters for use in QRS detection, and a derivative-based QRS detection algorithm. These filters achieve real-time speeds by requiring only integer arithmetic. They can be implemented on a diversity of available microprocessors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1985.325589

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 189

Metadata

Authors
Ahlstrom, M. L., & Tompkins, W. J.
Venue
IEEE Transactions on Biomedical Engineering
Published
1985-09
Volume
BME-32
Issue
9
Pages
708-713
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2019485089
Cited by
189
References
1
FWCI
2.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.