The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Digital Filters for Real-Time ECG Signal Processing Using Microprocessors
Abstract
Traditionally, analog circuits have been used for signal conditioning of electrocardiograms. As an alternative, algorithms implemented as programs on microprocessors can do similar filtering tasks. Also, digital filter algorithms can perform processes that are difficult or impossible using analog techniques. Presented here are a set of real-time digital filters each implemented as a subroutine. By calling these subroutines in an appropriate sequence, a user can cascade filters together to implement a desired filtering task on a single microprocessor. Included are an adaptive 60-Hz interference filter, two low-pass filters, a high-pass filter for eliminating dc offset in an ECG, an ECG data reduction algorithm, band-pass filters for use in QRS detection, and a derivative-based QRS detection algorithm. These filters achieve real-time speeds by requiring only integer arithmetic. They can be implemented on a diversity of available microprocessors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
Cited by
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043
A 48.6-to-105.2 µW Machine Learning Assisted Cardiac Sensor SoC for Mobile Healthcare Applications
Hsu, S.-Y., Ho, Y., Chang, P.-Y., Su, C., & Lee, C.-Y. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2297406 · Cited by 82
Metadata
- Authors
- Ahlstrom, M. L., & Tompkins, W. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1985-09
- Volume
- BME-32
- Issue
- 9
- Pages
- 708-713
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2019485089
- Cited by
- 189
- References
- 1
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.