Spatial Filtering of Noninvasive Multielectrode EMG: Part II-Filter Performance in Theory and Modeling
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Spatial filtering, particularly common in the field of engineering, is adapted in theory and practice to the filtering of propagating spatial EMG signals. This technique offers a new flexibility in the design of selective EMG measurement configurations. Longitudinal as well as two-dimensional spatial filters can be used. The conditions for the design of suitable spatial filters are deduced by signal theory. The performances of different selected configurations are compared by means of a given simple model of an excited motor unit. The modeling results compare well to the previously described experimental signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
Cited by
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
“A recent experimental study (29) and simulation analyses (17, 28, 51) suggest several conclusions about crosstalk: 1) signals detected far from the source are mainly due to the extinction of the action potentials at the ends of the fibers; 2) because of differences in the sources of the propagating and nonpropagating…”
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
Crosstalk in surface electromyography: Theoretical and practical estimates
Winter, D. A., Fuglevand, A. J., & Archer, S. E. (1994) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(94)90023-x · Cited by 390
Influence of anatomical, physical, and detection-system parameters on surface EMG
Farina, D., Cescon, C., & Merletti, R. (2002) · Biological Cybernetics · doi:10.1007/s00422-002-0309-2 · Cited by 373
Analysis of motor units with high-density surface electromyography
Merletti, R., Holobar, A., & Farina, D. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.09.002 · Cited by 350
Metadata
- Authors
- Reucher, H., Silny, J., & Rau, G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1987-02
- Volume
- BME-34
- Issue
- 2
- Pages
- 106-113
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2022575008
- Cited by
- 129
- References
- 1
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatial Filtering of Noninvasive Multielectrode EMG: Part II-Filter Performance in Theory and Modeling. https://app.cochat.ai/papers/10.1109/tbme.1987.326035
- The paper
- Reucher, H., Silny, J., & Rau, G. (1987). Spatial Filtering of Noninvasive Multielectrode EMG: Part II-Filter Performance in Theory and Modeling. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1987.326035
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.