The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Use of the Finite-Difference Time-Domain Method in Calculating EM Absorption in Human Tissues
Abstract
Although there are acceptable methods for calculating whole body electromagnetic absorption, no completely acceptable method for calculating the local specific absorption rate (SAR) at points within the body has been developed. Frequency domain methods, such as the method of moments (MoM) have achieved some success; however, MoM requires computer storage on the order of (3N) 2 and computation time on the order of (3N) 3 where N is the number of cells. The finite-difference time-domain (FDTD) method has been employed extensively in calculating the scattering of metallic objects, and recently is seeing some use in calculating the interaction of EM fields with complex, lossy dielectric bodies. Since the FDTD method has storage and time requirements proportional to N, it presents an attractive alternative to calculating SAR distribution in large bodies. This paper describes the FDTD method and evaluates it by comparing its results to analytic solutions in two and three dimensions. The utility of the FDTD method is demonstrated by a 3D scan of the human torso. The results obtained demonstrate that the FDTD method is capable of calculating internal SAR distribution with acceptable accuracy. With the availability of supercomputers, such as the CRAY II, the calculation of SAR distribution in a man model of 50 000 cells (1.27 cm per cell) appears to be feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yee, K. (1966) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1966.1138693 · Cited by 15,008
Mur, G. (1981) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.1981.303970 · Cited by 2,565
Radiation boundary conditions for wave‐like equations
Bayliss, A., & Turkel, E. (1980) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.3160330603 · Cited by 1,026
Cited by
Numerical methods in electromagnetic scattering theory
Kahnert, F. M. (2003) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/s0022-4073(02)00321-7 · Cited by 476
Frequency-dependent FDTD methods using Z transforms
Sullivan, D. M. (1992) · IEEE Transactions on Antennas and Propagation · doi:10.1109/8.182455 · Cited by 416
Self-citationSui, W., Christensen, D. A., & Durney, C. H. (1992) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.127522 · Cited by 360
Wu, T., Rappaport, T. S., & Collins, C. M. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2014.2377587 · Cited by 243
Metadata
- Authors
- Sullivan, D. M., Borup, D. T., & Gandhi, O. P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1987-02
- Volume
- BME-34
- Issue
- 2
- Pages
- 148-157
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2015793773
- Cited by
- 180
- References
- 3
- FWCI
- 13.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.