The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Retinal vascular tree morphology: a semi-automatic quantification
Abstract
A semi-automatic method to measure and quantify geometrical and topological properties of continuous vascular trees in clinical fundus images is described. Measurements are made from binary images obtained with a previously described segmentation process. The skeletons of the segmented trees are produced by thinning,ff branch and crossing points are identified and segments of the trees are labeled and stored as a chain code. The operator selects a tree to be measured and decides if it is an arterial or venous tree. An automatic process then measures the lengths, areas and angles of the individual segments of the tree. Geometrical data and the connectivity information between branches from continuous retinal vessel trees are tabulated. A number of geometrical properties and topological indexes are derived. Vessel diameters and branching angles are validated against manual measurements and several derived geometrical and topological properties are extracted from red-free fundus images of ten normotensive and ten age- and sex-matched hypertensive subjects and compared with previously reported results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,824
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Authors/Task Force Members:, Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehm236 · Cited by 2,384
Blood vessel segmentation methodologies in retinal images – A survey
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.03.009 · Cited by 1,001
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
Metadata
- Authors
- Martinez-Perez, M. E., Highes, A. D., Stanton, A. V., Thorn, S. A., Chapman, N., Bharath, A. A., & Parker, K. H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2002-08
- Volume
- 49
- Issue
- 8
- Pages
- 912-917
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2108969748
- Cited by
- 241
- References
- 1
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Retinal vascular tree morphology: a semi-automatic quantification. https://app.cochat.ai/papers/10.1109/tbme.2002.800789
- The paper
- Martinez-Perez, M. E., Highes, A. D., Stanton, A. V., Thorn, S. A., Chapman, N., Bharath, A. A., & Parker, K. H. (2002). Retinal vascular tree morphology: a semi-automatic quantification. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2002.800789
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.