A novel method for the detection of apnea and hypopnea events in respiration signals
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The monitoring of breathing dynamics is an essential diagnostic tool in various clinical environments, such as sleep diagnostics, intensive care and neonatal monitoring. This paper introduces an innovative signal classification method that is capable of on-line detection of the presence or absence of normal breathing. Four different artificial neural networks are presented for the recognition of three different patterns in the respiration signals (normal breathing, hypopnea, and apnea). Two networks process the normalized respiration signals directly, while another two use sophisticatedly preprocessed signals. The development of the networks was based on training sets from the polysomnographic records of nine different patients. The detection performance of the networks was tested and compared by using up to 8000 untrained breathing patterns from 16 different patients. The networks which classified the preprocessed respiration signals produced an average detection performance of over 90%. In the light of the moderate computational power used, the presented method is not only viable in clinical polysomnographs and respiration monitors, but also in portable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Cited by
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
Sleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
A study on a non-contacting respiration signal monitoring system using Doppler ultrasound
Min, S. D., Yoon, D. J., Yoon, S. W., Yun, Y. H., & Lee, M. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0246-2 · Cited by 40
“Sleep apnea syndrome (SAS) is a sleep disorder widely found in modern society [10].”
Background
Metadata
- Authors
- Varady, P., Micsik, T., Benedek, S., & Benyo, Z.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2002-09
- Volume
- 49
- Issue
- 9
- Pages
- 936-942
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2170268036
- Cited by
- 197
- References
- 1
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel method for the detection of apnea and hypopnea events in respiration signals. https://app.cochat.ai/papers/10.1109/tbme.2002.802009
- The paper
- Varady, P., Micsik, T., Benedek, S., & Benyo, Z. (2002). A novel method for the detection of apnea and hypopnea events in respiration signals. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2002.802009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.