Two multichannel integrated circuits for neural recording and signal processing
The DOI matches its Crossref record.
Abstract
We have developed, manufactured, and tested two analog CMOS integrated circuit "neurochips" for recording from arrays of densely packed neural electrodes. Device A is a 16-channel buffer consisting of parallel noninverting amplifiers with a gain of 2 V/V. Device B is a 16-channel two-stage analog signal processor with differential amplification and high-pass filtering. It features selectable gains of 250 and 500 V/V as well as reference channel selection. The resulting amplifiers on Device A had a mean gain of 1.99 V/V with an equivalent input noise of 10 microV(rms). Those on Device B had mean gains of 53.4 and 47.4 dB with a high-pass filter pole at 211 Hz and an equivalent input noise of 4.4 microV(rms). Both devices were tested in vivo with electrode arrays implanted in the somatosensory cortex.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Self-citationOlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181
“Recently, progress has been made in the development of both active (with integrated circuitry) neural recording arrays [1], [10] and neural interface circuits [11]–[13].”
BackgroundA Fully Integrated Neural Recording Amplifier With DC Input Stabilization
Mohseni, P., & Najafi, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824126 · Cited by 173
“One of the earliest works in this area suggested using a reverse-biased diode to clamp the input with the high resistance of the junction depletion region [6].”
BackgroundIntegrated circuit amplifiers for multi-electrode intracortical recording
Jochum, T., Denison, T., & Wolf, P. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/012001 · Cited by 167
Self-citation
Metadata
- Authors
- Obeid, I., Morizio, J. C., Moxon, K. A., Nicolelis, M. A. L., & Wolf, P. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2003-02
- Volume
- 50
- Issue
- 2
- Pages
- 255-258
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2111743409
- Cited by
- 85
- References
- 0
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two multichannel integrated circuits for neural recording and signal processing. https://app.cochat.ai/papers/10.1109/tbme.2002.807643
- The paper
- Obeid, I., Morizio, J. C., Moxon, K. A., Nicolelis, M. A. L., & Wolf, P. D. (2003). Two multichannel integrated circuits for neural recording and signal processing. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2002.807643
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.