A comparison of algorithms for detection of spikes in the electroencephalogram
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Identification of the short transient waveform, called a spike, in the cortical electroencephalogram (EEG) plays an important role during diagnosis of neurological disorders such as epilepsy. It has been suggested that artificial neural networks (ANN) can be employed for spike detection in the EEG, if suitable features are provided as input to an ANN. In this paper, we explore the performance of neural network-based classifiers using features selected by algorithms suggested by four previous investigators. Of these, three algorithms model the spike by mathematical parameters and use them as features for classification while the fourth algorithm uses raw EEG to train the classifier. The objective of this paper is to examine if there is any inherent advantage to any particular set of features, subject to the condition that the same data are used for all feature selection algorithms. Our results suggest that artificial neural networks trained with features selected using any one of the above three algorithms as well as raw EEG directly fed to the ANN will yield similar results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The wavelet transform, time-frequency localization and signal analysis
Daubechies, I. (1990) · IEEE Transactions on Information Theory · doi:10.1109/18.57199 · Cited by 6,483 · cited 2×
“As a result, the WT was used to generate a finite number of features [1].”
Method
Cited by
Entropies for detection of epilepsy in EEG
Kannathal, N., Choo, M. L., Acharya, U. R., & Sadasivan, P. K. (2005) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2005.06.012 · Cited by 753
Khandoker, A. H., Palaniswami, M., & Karmakar, C. K. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2004495 · Cited by 367
Begg, R., & Kamruzzaman, J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.002 · Cited by 326
An ensemble system for automatic sleep stage classification using single channel EEG signal
Koley, B., & Dey, D. (2012) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2012.09.012 · Cited by 291
A review of EEG and MEG epileptic spike detection algorithms
Abd El-Samie, F. E., Alotaiby, T. N., Khalid, M. I., Alshebeili, S. A., & Aldosari, S. A. (2018) · IEEE Access · doi:10.1109/access.2018.2875487 · Cited by 82
“Spike-like activities or artifacts, such as the saccadic spike artifact, may also occur in some channels, and these activities need to be filtered out to reduce false detections [27].”
Background
Metadata
- Authors
- Pang, C. C. C., Upton, A. R. M., Shine, G., & Kamath, M. V.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2003-04
- Volume
- 50
- Issue
- 4
- Pages
- 521-526
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2144584391
- Cited by
- 121
- References
- 1
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of algorithms for detection of spikes in the electroencephalogram. https://app.cochat.ai/papers/10.1109/tbme.2003.809479
- The paper
- Pang, C. C. C., Upton, A. R. M., Shine, G., & Kamath, M. V. (2003). A comparison of algorithms for detection of spikes in the electroencephalogram. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2003.809479
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.