The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Support Vector Machines for Automated Recognition of Obstructive Sleep Apnea Syndrome From ECG Recordings
Open accessAbstract
Obstructive sleep apnea syndrome (OSAS) is associated with cardiovascular morbidity as well as excessive daytime sleepiness and poor quality of life. In this study, we apply a machine learning technique [support vector machines (SVMs)] for automated recognition of OSAS types from their nocturnal ECG recordings. A total of 125 sets of nocturnal ECG recordings acquired from normal subjects (OSAS - ) and subjects with OSAS (OSAS +), each of approximately 8 h in duration, were analyzed. Features extracted from successive wavelet coefficient levels after wavelet decomposition of signals due to heart rate variability (HRV) from RR intervals and ECG-derived respiration (EDR) from R waves of QRS amplitudes were used as inputs to the SVMs to recognize OSAS +/- subjects. Using leave-one-out technique, the maximum accuracy of classification for 83 training sets was found to be 100% for SVMs using a subset of selected combination of HRV and EDR features. Independent test results on 42 subjects showed that it correctly recognized 24 out of 26 OSAS + subjects and 15 out of 16 OSAS - subjects (accuracy = 92.85%; Cohen's kappa value of 0.85). For estimating the relative severity of OSAS, the posterior probabilities of SVM outputs were calculated and compared with respective apnea/hypopnea index. These results suggest superior performance of SVMs in OSAS recognition supported by wavelet-based features of ECG. The results demonstrate considerable potential in applying SVMs in an ECG-based screening device that can aid a sleep specialist in the initial assessment of patients with suspected OSAS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
The Nature of Statistical Learning Theory
Vapnik, V. N. (1995) · doi:10.1007/978-1-4757-2440-0 · Cited by 39,138
Neural Networks: A Comprehensive Foundation
Haykin, S. (1998) · Cited by 30,070
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Neural Networks for Pattern Recognition
Bishop, C. M. (1995) · doi:10.1093/oso/9780198538493.001.0001 · Cited by 12,287
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 11,772
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183
Cited by
Federated learning of predictive models from federated Electronic Health Records
Brisimi, T. S., Chen, R., Mela, T., Olshevsky, A., Paschalidis, I. C., & Shi, W. (2018) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2018.01.007 · Cited by 997
“[6] Results in the literature suggest that sparse classifiers (i.e., those that rely on few features), have strong predictive power and generalize well out-of-sample,[7,8] providing at the same time interpretability in both models and results.”
BackgroundKaplan Berkaya, S., Uysal, A. K., Sora Gunal, E., Ergin, S., Gunal, S., & Gulmezoglu, M. B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.03.003 · Cited by 610
Pourbabaee, B., Roshtkhari, M. J., & Khorasani, K. (2018) · IEEE Transactions on Systems, Man, and Cybernetics: Systems · doi:10.1109/tsmc.2017.2705582 · Cited by 411
A Novel Algorithm for the Automatic Detection of Sleep Apnea From Single-Lead ECG
Varon, C., Caicedo, A., Testelmans, D., Buyse, B., & Van Huffel, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2422378 · Cited by 347
Apnea medassist: Real-time sleep apnea monitor using single-lead ECG
Bsoul, M., Minn, H., & Tamil, L. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2087386 · Cited by 297
Metadata
- Authors
- Khandoker, A. H., Palaniswami, M., & Karmakar, C. K.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2009-01
- Volume
- 13
- Issue
- 1
- Pages
- 37-48
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2134643078
- Cited by
- 367
- References
- 58
- FWCI
- 8.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Support Vector Machines for Automated Recognition of Obstructive Sleep Apnea Syndrome From ECG Recordings. https://app.cochat.ai/papers/10.1109/titb.2008.2004495
- The paper
- Khandoker, A. H., Palaniswami, M., & Karmakar, C. K. (2009). Support Vector Machines for Automated Recognition of Obstructive Sleep Apnea Syndrome From ECG Recordings. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2008.2004495
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.