Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data?
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The analysis of the mechanics of the musculo-skeletal system during the execution of a motor task requires the determination of the instantaneous position and orientation of the body segments involved in relation to an inertial system of reference. By using adequately assembled uniaxial accelerometric sensors, an easy-to-manage measurement system can be obtained that estimates the three-dimensional position and orientation (P&O) of a body segment through an appropriate analytical model. However, the extent to which experimental errors, in particular accelerometers (ACs) assembly inaccuracies, affect such estimation has never been systematically investigated. This paper systematically analyzes the sensitivity of analytical models of body segment P&O reconstruction through a six-AC system and a nine-AC system to different sources of experimental error. We simulated and statistically assessed the performance of these models in the case of body segment motions typical of movements under muscular control. The results obtained indicated that the inaccuracy in the orientation of the individual AC's active axes and the offset error in the AC responses were the major sources of P&O estimation errors. In particular, no accurate estimation of position was possible with the analytical models analyzed. Under the motion conditions simulated in this study, no substantial advantages were found in using a nine-AC system rather than a six-AC system. Considering that the magnitudes of the simulated experimental errors were quite low (< or = 0.1 deg: AC's orientation; < or = 10(-4) m: uncertainty of the distance between two ACs; < or = 10(-2) ms(-2): random error; 0.5 x 10(-2) ms(-2): offset error), the results indicate that none of the two ACs systems analyzed is suitable for body segment P&O estimation in routine biomechanical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jankovic, J., Schwartz, K., Clemence, W., Aswad, A., & Mordaunt, J. (1996) · Movement Disorders · doi:10.1002/mds.870110306 · Cited by 235 · cited 1×
“In the literature, ACs were used to monitor the level of human physical activity [8], to assess tremors [7] or to measure the deformation wave that travels along the skeletal system when the foot impacts the floor during locomotion [9].”
Method
Cited by
Sensor networks for medical care
Shnayder, V., Chen, B.-R., Lorincz, K., Jones, T. R. F. F., & Welsh, M. (2005) · Proceedings of the 3rd international conference on Embedded networked sensor systems · doi:10.1145/1098918.1098979 · Cited by 720
The internet of things in healthcare: An overview
YIN, Y., Zeng, Y., Chen, X., & Fan, Y. (2016) · Journal of Industrial Information Integration · doi:10.1016/j.jii.2016.03.004 · Cited by 589
Roetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588
Wearable soft sensing suit for human gait measurement
Mengüç, Y., Park, Y.-L., Pei, H., Vogt, D., Aubin, P. M., Winchell, E., Fluke, L., Stirling, L., Wood, R. J., & Walsh, C. J. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364914543793 · Cited by 415
Advances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing
Sabatini, A. M. (2011) · Sensors · doi:10.3390/s110201489 · Cited by 349
“The six-nine sensor configurations were analyzed in depth in [9], to conclude that severe restrictions exist in the time duration over which motion tracking is feasible by accelerometry methods in routine biomechanical applications.”
BackgroundGait analysis using gravitational acceleration measured by wearable sensors
Takeda, R., Tadano, S., Todoh, M., Morikawa, M., Nakayasu, M., & Yoshinari, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.10.027 · Cited by 128
“Giansanti et al. conducted simulations with acceleration sensors and reported the inclination and position errors for various motions (Giansanti et al., 2003).”
BackgroundMethodEstimation of Upper-Limb Orientation Based on Accelerometer and Gyroscope Measurements
Hyde, R. A., Ketteringham, L. P., Neild, S. A., & Jones, R. J. S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912647 · Cited by 98
Metadata
- Authors
- Giansanti, D., Macellari, V., Maccioni, G., & Cappozzo, A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2003-04
- Volume
- 50
- Issue
- 4
- Pages
- 476-483
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2127321491
- Cited by
- 127
- References
- 1
- FWCI
- 14.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.