CoChat

Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data?

Giansanti, D., Macellari, V., Maccioni, G., Cappozzo, A. · 2003 · IEEE Transactions on Biomedical Engineering
Cited by 127

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The analysis of the mechanics of the musculo-skeletal system during the execution of a motor task requires the determination of the instantaneous position and orientation of the body segments involved in relation to an inertial system of reference. By using adequately assembled uniaxial accelerometric sensors, an easy-to-manage measurement system can be obtained that estimates the three-dimensional position and orientation (P&O) of a body segment through an appropriate analytical model. However, the extent to which experimental errors, in particular accelerometers (ACs) assembly inaccuracies, affect such estimation has never been systematically investigated. This paper systematically analyzes the sensitivity of analytical models of body segment P&O reconstruction through a six-AC system and a nine-AC system to different sources of experimental error. We simulated and statistically assessed the performance of these models in the case of body segment motions typical of movements under muscular control. The results obtained indicated that the inaccuracy in the orientation of the individual AC's active axes and the offset error in the AC responses were the major sources of P&O estimation errors. In particular, no accurate estimation of position was possible with the analytical models analyzed. Under the motion conditions simulated in this study, no substantial advantages were found in using a nine-AC system rather than a six-AC system. Considering that the magnitudes of the simulated experimental errors were quite low (< or = 0.1 deg: AC's orientation; < or = 10(-4) m: uncertainty of the distance between two ACs; < or = 10(-2) ms(-2): random error; 0.5 x 10(-2) ms(-2): offset error), the results indicate that none of the two ACs systems analyzed is suitable for body segment P&O estimation in routine biomechanical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2003.809490

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Giansanti, D., Macellari, V., Maccioni, G., & Cappozzo, A.
Venue
IEEE Transactions on Biomedical Engineering
Published
2003-04
Volume
50
Issue
4
Pages
476-483
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2127321491
Cited by
127
References
1
FWCI
14.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.