BCI Competition 2003—Data Set Ia: Combining Gamma-Band Power With Slow Cortical Potentials to Improve Single-Trial Classification of Electroencephalographic Signals
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In one type of brain-computer interface (BCI), users self-modulate brain activity as detected by electroencephalography (EEG). To infer user intent, EEG signals are classified by algorithms which typically use only one of the several types of information available in these signals. One such BCI uses slow cortical potential (SCP) measures to classify single trials. We complemented these measures with estimates of high-frequency (gamma-band) activity, which has been associated with attentional and intentional states. Using a simple linear classifier, we obtained significantly greater classification accuracy using both types of information from the same recording epochs compared to using SCPs alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“Digital Object Identifier 10.1109/TBME.2004.827081 In several of these [3]–[5], the subject learns to modulate the amplitude of mu (8–12 Hz) or high-beta (18–26 Hz) rhythms on the scalp just above the motor cortex.”
BackgroundInfluentialFarwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“Other systems use the P300 event-related potential [6], [7] or slow cortical potentials (SCPs) [8], [9] as the BCI control signal.”
MethodBlankertz, B., Muller, K.-R., Curio, G., Vaughan, T. M., Schalk, G., Wolpaw, J. R., Schlogl, A., Neuper, C., Pfurtscheller, G., Hinterberger, T., et al. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826692 · Cited by 670
The thought translation device (TTD) for completely paralyzed patients
Birbaumer, N., Kubler, A., Ghanayim, N., Hinterberger, T., Perelmouter, J., Kaiser, J., Iversen, I., Kotchoubey, B., Neumann, N., & Flor, H. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847812 · Cited by 493 · cited 1×
“Other systems use the P300 event-related potential [6], [7] or slow cortical potentials (SCPs) [8], [9] as the BCI control signal.”
MethodDesmedt, J. E., & Tomberg, C. (1994) · Neuroscience Letters · doi:10.1016/0304-3940(94)90432-4 · Cited by 240 · cited 1×
“Oscillations at higher frequencies (gamma-band, variably defined as 24– Hz) in the human brain have been widely associated with integrative functions and awareness [11]–[15].”
BackgroundGross, D. W., & Gotman, J. (1999) · Neuroscience · doi:10.1016/s0306-4522(99)00343-7 · Cited by 184
Cited by
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Blankertz, B., Muller, K.-R., Curio, G., Vaughan, T. M., Schalk, G., Wolpaw, J. R., Schlogl, A., Neuper, C., Pfurtscheller, G., Hinterberger, T., et al. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826692 · Cited by 670
“The winning labs are publishing individual papers on their approaches; see [7]–[13].”
BackgroundEMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
EEG feature extraction based on wavelet packet decomposition for brain computer interface
Ting, W., Guo-zheng, Y., Bang-hua, Y., & Hong, S. (2008) · Measurement · doi:10.1016/j.measurement.2007.07.007 · Cited by 366
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Open Access Dataset for EEG+NIRS Single-Trial Classification
Shin, J., von Luhmann, A., Blankertz, B., Kim, D.-W., Jeong, J., Hwang, H.-J., & Muller, K.-R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2628057 · Cited by 287
Metadata
- Authors
- Mensh, B. D., Werfel, J., & Seung, H. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-06
- Volume
- 51
- Issue
- 6
- Pages
- 1052-1056
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2128379882
- Cited by
- 140
- References
- 6
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.