Surrogate Data Analysis for Assessing the Significance of the Coherence Function
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
In cardiovascular variability analysis, the significance of the coupling between two time series is commonly assessed by setting a threshold level in the coherence function. While traditionally used statistical tests consider only the parameters of the adopted estimator, the required zero-coherence level may be affected by some features of the observed series. In this study, three procedures, based on the generation of surrogate series sharing given properties with the original but being structurally uncoupled, were considered: independent identically distributed (IID), Fourier transform (FT), and autoregressive (AR). IID surrogates maintained the distribution of the original series, while FT and AR surrogates preserved the power spectrum. The ability of the three methods to define the threshold for zero coherence was validated and compared by computer simulations reproducing typical cardiovascular interactions. While the IID threshold depended only on record length and design parameters of the coherence estimator, FT and AR thresholds were frequency-dependent with peaks corresponding to the local maxima of the estimated coherence. FT and AR surrogates were able to compensate spurious coherence peaks due to equal-frequency but independent oscillations in the two series. The benefit of frequency-dependent thresholds was evident for short series with narrow-band oscillations. Thus, surrogates preserving the power spectrum of the original series are recommended to avoid false coupling detections in the presence of oscillations occurring at nearby frequencies but produced by different mechanisms, as may frequently happen in cardiovascular and cardiorespiratory regulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new look at the statistical model identification
Akaike, H. (1974) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1974.1100705 · Cited by 51,879 · cited 1×
“Power spectral density functions of (a) were normalized to their maximum value to allow their superposition. used to fit the original data was optimized by means of the Akaike criterion [23].”
MethodHeart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289 · cited 1×
“The two shapes are thought to be representative of the heart rate or arterial pressure variability in a normal subject in resting condition [25].”
Spectral Analysis and Time Series
Preston, D. B. (1983) · Technometrics · doi:10.1080/00401706.1983.10487866 · Cited by 5,011 · cited 4×
“been proposed by Amos and Koopmans [10] and later improved by other investigators [11]; only recently has this approach been applied to the field of short-term cardiovascular variability analysis [28].”
BackgroundMethodInfluentialSpectral Analysis and its Applications.
Freiberger, W. F., Jenkins, G. M., & Watts, D. G. (1969) · Journal of the American Statistical Association · doi:10.2307/2286100 · Cited by 4,981
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798
Testing for nonlinearity in time series: the method of surrogate data
Theiler, J., Eubank, S., Longtin, A., Galdrikian, B., & Doyne Farmer, J. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90102-s · Cited by 3,732
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
Rovere, M. T. L., Bigger, J. T., Marcus, F. I., Mortara, A., & Schwartz, P. J. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11144-8 · Cited by 3,120
Modern Spectral Estimation: Theory and Application
Kay, S. (1988) · Medical Entomology and Zoology · Cited by 2,480
Cited by
Nonlinear multivariate analysis of neurophysiological signals
Pereda, E., Quiroga, R. Q., & Bhattacharya, J. (2005) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2005.10.003 · Cited by 1,076
Surrogate data for hypothesis testing of physical systems
Lancaster, G., Iatsenko, D., Pidde, A., Ticcinelli, V., & Stefanovska, A. (2018) · Physics Reports · doi:10.1016/j.physrep.2018.06.001 · Cited by 422
Cohen, D., van Swinderen, B., & Tsuchiya, N. (2018) · eneuro · doi:10.1523/eneuro.0329-17.2018 · Cited by 23
Metadata
- Authors
- Faes, L., Pinna, G. D., Porta, A., Maestri, R., & Nollo, G. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-07
- Volume
- 51
- Issue
- 7
- Pages
- 1156-1166
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2099764401
- Cited by
- 196
- References
- 34
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surrogate Data Analysis for Assessing the Significance of the Coherence Function. https://app.cochat.ai/papers/10.1109/tbme.2004.827271
- The paper
- Faes, L., Pinna, G. D., Porta, A., Maestri, R., & Nollo, G. D. (2004). Surrogate Data Analysis for Assessing the Significance of the Coherence Function. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2004.827271
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.