CoChat

Surrogate Data Analysis for Assessing the Significance of the Coherence Function

Faes, L., Pinna, G.D., Porta, A., Maestri, R., Nollo, G.D. · 2004 · IEEE Transactions on Biomedical Engineering
Cited by 196

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

In cardiovascular variability analysis, the significance of the coupling between two time series is commonly assessed by setting a threshold level in the coherence function. While traditionally used statistical tests consider only the parameters of the adopted estimator, the required zero-coherence level may be affected by some features of the observed series. In this study, three procedures, based on the generation of surrogate series sharing given properties with the original but being structurally uncoupled, were considered: independent identically distributed (IID), Fourier transform (FT), and autoregressive (AR). IID surrogates maintained the distribution of the original series, while FT and AR surrogates preserved the power spectrum. The ability of the three methods to define the threshold for zero coherence was validated and compared by computer simulations reproducing typical cardiovascular interactions. While the IID threshold depended only on record length and design parameters of the coherence estimator, FT and AR thresholds were frequency-dependent with peaks corresponding to the local maxima of the estimated coherence. FT and AR surrogates were able to compensate spurious coherence peaks due to equal-frequency but independent oscillations in the two series. The benefit of frequency-dependent thresholds was evident for short series with narrow-band oscillations. Thus, surrogates preserving the power spectrum of the original series are recommended to avoid false coupling detections in the presence of oscillations occurring at nearby frequencies but produced by different mechanisms, as may frequently happen in cardiovascular and cardiorespiratory regulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2004.827271

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 196

Metadata

Authors
Faes, L., Pinna, G. D., Porta, A., Maestri, R., & Nollo, G. D.
Venue
IEEE Transactions on Biomedical Engineering
Published
2004-07
Volume
51
Issue
7
Pages
1156-1166
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2099764401
Cited by
196
References
34
FWCI
4.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Surrogate Data Analysis for Assessing the Significance of the Coherence Function. https://app.cochat.ai/papers/10.1109/tbme.2004.827271
The paper
Faes, L., Pinna, G. D., Porta, A., Maestri, R., & Nollo, G. D. (2004). Surrogate Data Analysis for Assessing the Significance of the Coherence Function. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2004.827271

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.