The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Sequential Finite Element Model of Tissue Electropermeabilization
Abstract
Permeabilization, when observed on a tissue level, is a dynamic process resulting from changes in membrane permeability when exposing biological cells to external electric field (E). In this paper we present a sequential finite element model of E distribution in tissue which considers local changes in tissue conductivity due to permeabilization. These changes affect the pattern of the field distribution during the high voltage pulse application. The presented model consists of a sequence of static models (steps), which describe E distribution at discrete time intervals during tissue permeabilization and in this way present the dynamics of electropermeabilization. The tissue conductivity for each static model in a sequence is determined based on E distribution from the previous step by considering a sigmoid dependency between specific conductivity and E intensity. Such a dependency was determined by parameter estimation on a set of current measurements, obtained by in vivo experiments. Another set of measurements was used for model validation. All experiments were performed on rabbit liver tissue with inserted needle electrodes. Model validation was carried out in four different ways: 1) by comparing reversibly permeabilized tissue computed by the model and the reversibly permeabilized area of tissue as obtained in the experiments; 2) by comparing the area of irreversibly permeabilized tissue computed by the model and the area where tissue necrosis was observed in experiments; 3) through the comparison of total current at the end of pulse and computed current in the last step of sequential electropermeabilization model; 4) by comparing total current during the first pulse and current computed in consecutive steps of a modeling sequence. The presented permeabilization model presents the first approach of describing the course of permeabilization on tissue level. Despite some approximations (ohmic tissue behavior) the model can predict the permeabilized volume of tissue, when exposed to electrical treatment. Therefore, the most important contribution and novelty of the model is its potentiality to be used as a tool for determining parameters for effective tissue permeabilization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Theory of electroporation: A review
Weaver, J. C., & Chizmadzhev, Y. A. (1996) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(96)05062-3 · Cited by 1,599
Electroporation of cell membranes
Tsong, T. Y. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82054-9 · Cited by 1,094
Gene transfer into muscle by electroporation in vivo
Aihara, H., & Miyazaki, J.-I. (1998) · Nature Biotechnology · doi:10.1038/nbt0998-867 · Cited by 944
High-efficiency gene transfer into skeletal muscle mediated by electric pulses
Mir, L. M., Bureau, M. F., Gehl, J., Rangara, R., Rouy, D., Caillaud, J.-M., Delaere, P., Branellec, D., Schwartz, B., & Scherman, D. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.8.4262 · Cited by 914
Self-citationChang, D. C., & Reese, T. S. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82348-1 · Cited by 522
Formation and resealing of pores of controlled sizes in human erythrocyte membrane
KINOSITA, K., & TSONG, T. Y. (1977) · Nature · doi:10.1038/268438a0 · Cited by 501
Resistivity of Body Tissues at Low Frequencies
RUSH, S., ABILDSKOV, J. A., & MCFEE, R. (1963) · Circulation Research · doi:10.1161/01.res.12.1.40 · Cited by 447
In vivo electrically mediated protein and gene transfer in murine melanoma
Rols, M.-P., Delteil, C., Golzio, M., Dumond, P., Cros, S., & Teissie, J. (1998) · Nature Biotechnology · doi:10.1038/nbt0298-168 · Cited by 421
Cited by
In Vivo Results of a New Focal Tissue Ablation Technique: Irreversible Electroporation
Edd, J. F., Horowitz, L., Davalos, R. V., Mir, L. M., & Rubinsky, B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873745 · Cited by 510
Self-citationElectroporation in Food Processing and Biorefinery
Mahnič-Kalamiza, S., Vorobiev, E., & Miklavčič, D. (2014) · The Journal of Membrane Biology · doi:10.1007/s00232-014-9737-x · Cited by 281
Sano, M. B., Neal, R. E., Garcia, P. A., Gerber, D., Robertson, J., & Davalos, R. V. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-83 · Cited by 117
Metadata
- Authors
- Sel, D., Cukjati, D., Batiuskaite, D., Slivnik, T., Mir, L. M., & Miklavcic, D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2005-05
- Volume
- 52
- Issue
- 5
- Pages
- 816-827
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2094626068
- Cited by
- 284
- References
- 38
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sequential Finite Element Model of Tissue Electropermeabilization. https://app.cochat.ai/papers/10.1109/tbme.2005.845212
- The paper
- Sel, D., Cukjati, D., Batiuskaite, D., Slivnik, T., Mir, L. M., & Miklavcic, D. (2005). Sequential Finite Element Model of Tissue Electropermeabilization. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2005.845212
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.