Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Robust detection and classification of longitudinal changes in color retinal fundus images for monitoring diabetic retinopathy

Narasimha-Iyer, H., Can, A., Roysam, B., Stewart, V., Tanenbaum, H.L., Majerovics, A., Singh, H. · 2006 · IEEE Transactions on Biomedical Engineering

Abstract

A fully automated approach is presented for robust detection and classification of changes in longitudinal time-series of color retinal fundus images of diabetic retinopathy. The method is robust to: 1) spatial variations in illumination resulting from instrument limitations and changes both within, and between patient visits; 2) imaging artifacts such as dust particles; 3) outliers in the training data; 4) segmentation and alignment errors. Robustness to illumination variation is achieved by a novel iterative algorithm to estimate the reflectance of the retina exploiting automatically extracted segmentations of the retinal vasculature, optic disk, fovea, and pathologies. Robustness to dust artifacts is achieved by exploiting their spectral characteristics, enabling application to film-based, as well as digital imaging systems. False changes from alignment errors are minimized by subpixel accuracy registration using a 12-parameter transformation that accounts for unknown retinal curvature and camera parameters. Bayesian detection and classification algorithms are used to generate a color-coded output that is readily inspected. A multiobserver validation on 43 image pairs from 22 eyes involving nonproliferative and proliferative diabetic retinopathies, showed a 97% change detection rate, a 3% miss rate, and a 10% false alarm rate. The performance in correctly classifying the changes was 99.3%. A self-consistency metric, and an error factor were developed to measure performance over more than two periods. The average self consistency was 94% and the error factor was 0.06%. Although this study focuses on diabetic changes, the proposed techniques have broader applicability in ophthalmology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2005.863971

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 170

Metadata

Authors
Narasimha-Iyer, H., Can, A., Roysam, B., Stewart, V., Tanenbaum, H. L., Majerovics, A., & Singh, H.
Venue
IEEE Transactions on Biomedical Engineering
Published
2006-06
Volume
53
Issue
6
Pages
1084-1098
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2121233747
Cited by
170
References
1
FWCI
4.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Robust detection and classification of longitudinal changes in color retinal fundus images for monitoring diabetic retinopathy. https://app.cochat.ai/papers/10.1109/tbme.2005.863971
The paper
Narasimha-Iyer, H., Can, A., Roysam, B., Stewart, V., Tanenbaum, H. L., Majerovics, A., & Singh, H. (2006). Robust detection and classification of longitudinal changes in color retinal fundus images for monitoring diabetic retinopathy. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2005.863971

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.