CoChat

Run-to-run control of blood glucose concentrations for people with type 1 diabetes mellitus

Open access
Owens, C., Zisser, H., Jovanovic, L., Srinivasan, B., Bonvin, D., Doyle, F.J. · 2006 · IEEE Transactions on Biomedical Engineering
Cited by 122

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Run-to-run control has been applied to several traditional batch processes in the chemical industry. The 24-h cycle of eating meals, measuring blood glucose concentrations, and delivering the correct insulin bolus, with the goal of achieving the optimal blood glucose profile, can be viewed in the same spirit as traditional batch processes such as emulsion polymerization. In this paper, we aim to exploit the "repetitive" nature of the insulin therapy of people with Type 1 diabetes. A run-to-run algorithm is used on a virtual diabetic patient model to control blood glucose concentrations. The insulin input is parameterized into the timing and amount of the dose while the glucose output is parameterized into the maximum and minimum glucose concentrations. Robustness of the algorithm to variations in the meal amount, meal timing, and insulin sensitivity parameter is addressed. In general, the algorithm is able to converge when the meal timing is varied within +/- 40 min. If the meal size is underestimated by approximately 10 grams (g), the algorithm is able to converge within a reasonable time frame for breakfast, lunch, and dinner. If the meal size is overestimated by 20-25 g, the algorithm is able to converge. When random variations in the meal timing and the meal amount are introduced, the variation on the output variables, Gmax and Gmin, scales according to the amount of variation allowed. Along with this, the insulin sensitivity of the virtual patient model is varied. The algorithm is robust for differences in insulin sensitivity less than +/- 50% of the nominal value.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2006.872818

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 122

Metadata

Authors
Owens, C., Zisser, H., Jovanovic, L., Srinivasan, B., Bonvin, D., & Doyle, F. J.
Venue
IEEE Transactions on Biomedical Engineering
Published
2006-06
Volume
53
Issue
6
Pages
996-1005
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2116088335
Cited by
122
References
2
FWCI
5.24
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Run-to-run control of blood glucose concentrations for people with type 1 diabetes mellitus. https://app.cochat.ai/papers/10.1109/tbme.2006.872818
The paper
Owens, C., Zisser, H., Jovanovic, L., Srinivasan, B., Bonvin, D., & Doyle, F. J. (2006). Run-to-run control of blood glucose concentrations for people with type 1 diabetes mellitus. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.872818

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.