The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Robust Neural-Network-Based Classification of Premature Ventricular Contractions Using Wavelet Transform and Timing Interval Features
Abstract
Automatic electrocardiogram (ECG) beat classification is essential to timely diagnosis of dangerous heart conditions. Specifically, accurate detection of premature ventricular contractions (PVCs) is imperative to prepare for the possible onset of life-threatening arrhythmias. Although many groups have developed highly accurate algorithms for detecting PVC beats, results have generally been limited to relatively small data sets. Additionally, many of the highest classification accuracies (> 90%) have been achieved in experiments where training and testing sets overlapped significantly. Expanding the overall data set greatly reduces overall accuracy due to significant variation in ECG morphology among different patients. As a result, we believe that morphological information must be coupled with timing information, which is more constant among patients, in order to achieve high classification accuracy for larger data sets. With this approach, we combined wavelet-transformed ECG waves with timing information as our feature set for classification. We used select waveforms of 18 files of the MIT/BIH arrhythmia database, which provides an annotated collection of normal and arrhythmic beats, for training our neural-network classifier. We then tested the classifier on these 18 training files as well as 22 other files from the database. The accuracy was 95.16% over 93,281 beats from all 40 files, and 96.82% over the 22 files outside the training set in differentiating normal, PVC, and other beats.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Cited by
ECG beat classification using PCA, LDA, ICA and Discrete Wavelet Transform
Martis, R. J., Acharya, U. R., & Min, L. C. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.01.005 · Cited by 722
Convolutional Neural Networks for patient-specific ECG classification
Kiranyaz, S., Ince, T., Hamila, R., & Gabbouj, M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318926 · Cited by 309
Ham, S., Kang, M., Jang, S., Jang, J., Choi, S., Kim, T.-W., & Wang, G. (2020) · Science Advances · doi:10.1126/sciadv.aba1178 · Cited by 184
Metadata
- Authors
- Inan, O. T., Giovangrandi, L., & Kovacs, G. T. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-12
- Volume
- 53
- Issue
- 12
- Pages
- 2507-2515
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2140920882
- Cited by
- 402
- References
- 1
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust Neural-Network-Based Classification of Premature Ventricular Contractions Using Wavelet Transform and Timing Interval Features. https://app.cochat.ai/papers/10.1109/tbme.2006.880879
- The paper
- Inan, O. T., Giovangrandi, L., & Kovacs, G. T. A. (2006). Robust Neural-Network-Based Classification of Premature Ventricular Contractions Using Wavelet Transform and Timing Interval Features. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.880879
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.