Polarity Effect in Electrovibration for Tactile Display
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Electrovibration is the tactile sensation of an alternating potential between the human body and a smooth conducing surface when the skin slides over the surface and where the current is too small to stimulate sensory nerves directly. It has been proposed as a high-density tactile display method, for example to display pictographic information to persons who are blind. Previous models for the electrovibration transduction mechanism are based on a parallel-plate capacitor in which the electrostatic force is insensitive to polarity. We present experimental data showing that electrovibratory perceptual sensitivity to positive pulses is less than that for negative or biphasic pulses and propose that this disparity may be due to the asymmetric electrical properties of human skin. We furthermore propose using negative pulses for insulated tactile displays based on electrovibration because their sensory thresholds were found to be more stable than for waveforms incorporating positive pulses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Self-citationDetection of Vibration Transmitted Through an Object Grasped in the Hand
Brisben, A. J., Hsiao, S. S., & Johnson, K. O. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.4.1548 · Cited by 259 · cited 1×
“This shear force deforms the skin, the sensory apparatus of which is sensitive to both normal and shear vibration in the range 40‐800 Hz, with sensory thresholds as low as 0.1 m, depending on frequency and contactor size [ 4 ], [5].”
BackgroundInfluential
Cited by
Flexible Electronics: The Next Ubiquitous Platform
Nathan, A., Ahnood, A., Cole, M. T., Lee, S., Suzuki, Y., Hiralal, P., Bonaccorso, F., Hasan, T., Garcia-Gancedo, L., Dyadyusha, A., et al. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2190168 · Cited by 1,000
TeslaTouch: electrovibration for touch surfaces
Bau, O., Poupyrev, I., Israr, A., & Harrison, C. (2010) · Proceedings of the 23nd annual ACM symposium on User interface software and technology · doi:10.1145/1866029.1866074 · Cited by 664
Effect of Waveform on Tactile Perception by Electrovibration Displayed on Touch Screens
Vardar, Y., Guclu, B., & Basdogan, C. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2704603 · Cited by 130
“Previous studies showed that the human skin (especially sweat ducts and the stratumcorneum) is not a perfect dielectric and has frequency-dependent resistive properties [13], [16], [27], [28].”
BackgroundAudio-Tactile Skinny Buttons for Touch User Interfaces
Van Duong, Q., Nguyen, V. P., Luu, A. T., & Choi, S. T. (2019) · Scientific Reports · doi:10.1038/s41598-019-49640-w · Cited by 21
Textile Fabrics’ Texture: From Multi-level Feature Extraction to Tactile Simulation
Ben Messaoud, W., Bueno, M.-A., & Lemaire-Semail, B. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-42324-1_29 · Cited by 19
Metadata
- Authors
- Kaczmarek, K. A., Nammi, K., Agarwal, A. K., Tyler, M. E., Haase, S. J., & Beebe, D. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-10
- Volume
- 53
- Issue
- 10
- Pages
- 2047-2054
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2154842302
- Cited by
- 108
- References
- 2
- FWCI
- 0.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polarity Effect in Electrovibration for Tactile Display. https://app.cochat.ai/papers/10.1109/tbme.2006.881804
- The paper
- Kaczmarek, K. A., Nammi, K., Agarwal, A. K., Tyler, M. E., Haase, S. J., & Beebe, D. J. (2006). Polarity Effect in Electrovibration for Tactile Display. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.881804
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.