The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Patient-Adapting Heartbeat Classifier Using ECG Morphology and Heartbeat Interval Features
Open accessAbstract
An adaptive system for the automatic processing of the electrocardiogram (ECG) for the classification of heartbeats into one of the five beat classes recommended by ANSI/AAMI EC57:1998 standard is presented. The heartbeat classification system processes an incoming recording with a global-classifier to produce the first set of beat annotations. An expert then validates and if necessary corrects a fraction of the beats of the recording. The system then adapts by first training a local-classifier using the newly annotated beats and combines this with the global-classifier to produce an adapted classification system. The adapted system is then used to update beat annotations. The results of this study show that the performance of a patient adaptable classifier increases with the amount of training of the system on the local record. Crucially, the performance of the system can be significantly boosted with a small amount of adaptation even when all beats used for adaptation are from a single class. This study illustrates the ability to provide highly beneficial automatic arrhythmia monitoring and is an improvement on previously reported results for automated heartbeat classification systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Networks for Pattern Recognition
Bishop, C. M. (1995) · doi:10.1093/oso/9780198538493.001.0001 · Cited by 12,287
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909
Cited by
ECG beat classification using PCA, LDA, ICA and Discrete Wavelet Transform
Martis, R. J., Acharya, U. R., & Min, L. C. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.01.005 · Cited by 722
Heartbeat Classification Using Morphological and Dynamic Features of ECG Signals
Ye, C., Kumar, B. V. K. V., & Coimbra, M. T. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2213253 · Cited by 522
A deep learning approach for ECG-based heartbeat classification for arrhythmia detection
Sannino, G., & De Pietro, G. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2018.03.057 · Cited by 445
A novel application of deep learning for single-lead ECG classification
Mathews, S. M., Kambhamettu, C., & Barner, K. E. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.013 · Cited by 322
Convolutional Neural Networks for patient-specific ECG classification
Kiranyaz, S., Ince, T., Hamila, R., & Gabbouj, M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318926 · Cited by 309
Metadata
- Authors
- de Chazal, P., & Reilly, R. B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-12
- Volume
- 53
- Issue
- 12
- Pages
- 2535-2543
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2132300419
- Cited by
- 497
- References
- 2
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Patient-Adapting Heartbeat Classifier Using ECG Morphology and Heartbeat Interval Features. https://app.cochat.ai/papers/10.1109/tbme.2006.883802
- The paper
- de Chazal, P., & Reilly, R. B. (2006). A Patient-Adapting Heartbeat Classifier Using ECG Morphology and Heartbeat Interval Features. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.883802
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.