CoChat

The Tendon Network of the Fingers Performs Anatomical Computation at a Macroscopic Scale

Valero-Cuevas, F.J., Jae-Woong Yi, Brown, D., McNamara, R.V., Paul, C., Lipson, H. · 2007 · IEEE Transactions on Biomedical Engineering
Cited by 139

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Current thinking attributes information processing for neuromuscular control exclusively to the nervous system. Our cadaveric experiments and computer simulations show, however, that the tendon network of the fingers performs logic computation to preferentially change torque production capabilities. How this tendon network propagates tension to enable manipulation has been debated since the time of Vesalius and DaVinci and remains an unanswered question. We systematically changed the proportion of tension to the tendons of the extensor digitorum versus the two dorsal interosseous muscles of two cadaver fingers and measured the tension delivered to the proximal and distal interphalangeal joints. We find that the distribution of input tensions in the tendon network itself regulates how tensions propagate to the finger joints, acting like the switching function of a logic gate that nonlinearly enables different torque production capabilities. Computer modeling reveals that the deformable structure of the tendon networks is responsible for this phenomenon; and that this switching behavior is an effective evolutionary solution permitting a rich repertoire of finger joint actuation not possible with simpler tendon paths. We conclude that the structural complexity of this tendon network, traditionally oversimplified or ignored, may in fact be critical to understanding brain-body coevolution and neuromuscular control. Moreover, this form of information processing at the macroscopic scale is a new instance of the emerging principle of nonneural "somatic logic" found to perform logic computation such as in cellular networks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2006.889200

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 139

Metadata

Authors
Valero-Cuevas, F. J., Yi, J.-W., Brown, D., McNamara, R. V., Paul, C., & Lipson, H.
Venue
IEEE Transactions on Biomedical Engineering
Published
2007-06
Volume
54
Issue
6
Pages
1161-1166
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2143958693
Cited by
139
References
1
FWCI
6.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Tendon Network of the Fingers Performs Anatomical Computation at a Macroscopic Scale. https://app.cochat.ai/papers/10.1109/tbme.2006.889200
The paper
Valero-Cuevas, F. J., Yi, J.-W., Brown, D., McNamara, R. V., Paul, C., & Lipson, H. (2007). The Tendon Network of the Fingers Performs Anatomical Computation at a Macroscopic Scale. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.889200

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.