The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
EEG-Based Lapse Detection With High Temporal Resolution
Abstract
A warning system capable of reliably detecting lapses in responsiveness (lapses) has the potential to prevent many fatal accidents. We have developed a system capable of detecting lapses in real-time with second-scale temporal resolution. Data was from 15 subjects performing a visuomotor tracking task for two 1-hour sessions with concurrent electroencephalogram (EEG) and facial video recordings. The detector uses a neural network with normalized EEG log-power spectrum inputs from two bipolar EEG derivations, though we also considered a multichannel detector. Lapses, identified using a combination of video rating and tracking behavior, were used to train our detector. We compared detectors employing tapped delay-line linear perceptron, tapped delay-line multilayer perceptron (TDL-MLP), and long short-term memory (LSTM) recurrent neural networks operating continuously at 1 Hz. Using estimates of EEG log-power spectra from up to 4 s prior to a lapse improved detection compared with only using the most recent estimate. We report the first application of a LSTM to an EEG analysis problem. LSTM performance was equivalent to the best TDL-MLP network but did not require an input buffer. Overall performance was satisfactory with area under the curve from receiver operating characteristic analysis of 0.84 +/- 0.02 (mean +/- SE) and area under the precision-recall curve of 0.41 +/- 0.08.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
A specific role for the thalamus in mediating the interaction of attention and arousal in humans.
Portas, C. M., Rees, G., Howseman, A. M., Josephs, O., Turner, R., & Frith, C. D. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-21-08979.1998 · Cited by 395
Cited by
Applications of deep learning and reinforcement learning to biological data
Mahmud, M., Kaiser, M. S., Hussain, A., & Vassanelli, S. (2018) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2018.2790388 · Cited by 765
Tsiouris, Κ. Μ., Pezoulas, V. C., Zervakis, M., Konitsiotis, S., Koutsouris, D. D., & Fotiadis, D. I. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.019 · Cited by 632
Deep Learning and Its Applications in Biomedicine
Cao, C., Liu, F., Tan, H., Song, D., Shu, W., Li, W., Zhou, Y., Bo, X., & Xie, Z. (2018) · Genomics, Proteomics & Bioinformatics · doi:10.1016/j.gpb.2017.07.003 · Cited by 624
Deep learning in microscopy image analysis: a survey
Xing, F., Xie, Y., Su, H., Liu, F., & Yang, L. (2018) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2017.2766168 · Cited by 460
A multimodal approach to estimating vigilance using EEG and forehead EOG
Zheng, W.-L., & Lu, B.-L. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5a98 · Cited by 424
“In these cases, a decrease in vigilance (Grier, Warm, Dember, Matthews, Galinsky, Szalma & Parasuraman 2003) or a momentary lapse of attention (Peiris, Davidson, Bones & Jones 2011, Davidson, Jones & Peiris 2007) might severely endanger public transportation safety.”
BackgroundResultInfluential
Metadata
- Authors
- Davidson, P. R., Jones, R. D., & Peiris, M. T. R.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-05
- Volume
- 54
- Issue
- 5
- Pages
- 832-839
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2127864857
- Cited by
- 158
- References
- 2
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.