A Fully Integrated Mixed-Signal Neural Processor for Implantable Multichannel Cortical Recording
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A 64-channel neural processor has been developed for use in an implantable neural recording microsystem. In the Scan Mode, the processor is capable of detecting neural spikes by programmable positive, negative, or window thresholding. Spikes are tagged with their associated channel addresses and formed into 18-bit data words that are sent serially to the external host. In the Monitor Mode, two channels can be selected and viewed at high resolution for studies where the entire signal is of interest. The processor runs from a 3-V supply and a 2-MHz clock, with a channel scan rate of 64 kS/s and an output bit rate of 2 Mbps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Self-citationAn implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310 · cited 1×
“Time-domain multiplexers have been used to increase the number of recording channels while decreasing external lead counts and limiting circuit complexity, power dissipation, and size [6]–[12].”
MethodSelf-citationA three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858479 · Cited by 245
Self-citation
Cited by
Neural Mechanisms for Interacting with a World Full of Action Choices
Cisek, P., & Kalaska, J. F. (2010) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135409 · Cited by 1,543
“A still more ambitious approach 288 Cisek · Kalaska is to implant wireless multielectrode arrays in the brains of rats (Sodagar et al. 2007) or monkeys (Chestek et al. 2009) and record ensemble activity during free behavior.”
BackgroundA 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Self-citationTools for Probing Local Circuits: High-Density Silicon Probes Combined with Optogenetics
Buzsáki, G., Stark, E., Berényi, A., Khodagholy, D., Kipke, D. R., Yoon, E., & Wise, K. D. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.028 · Cited by 334
Self-citationLarge-scale, high-density (up to 512 channels) recording of local circuits in behaving animals
Berényi, A., Somogyvári, Z., Nagy, A. J., Roux, L., Long, J. D., Fujisawa, S., Stark, E., Leonardo, A., Harris, T. D., & Buzsáki, G. (2014) · Journal of Neurophysiology · doi:10.1152/jn.00785.2013 · Cited by 311
Metadata
- Authors
- Sodagar, A. M., Wise, K. D., & Najafi, K.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-06
- Volume
- 54
- Issue
- 6
- Pages
- 1075-1088
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2130316372
- Cited by
- 133
- References
- 3
- FWCI
- 15.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.