The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
A Nonlinear Bayesian Filtering Framework for ECG Denoising
Open accessAbstract
In this paper, a nonlinear Bayesian filtering framework is proposed for the filtering of single channel noisy electrocardiogram (ECG) recordings. The necessary dynamic models of the ECG are based on a modified nonlinear dynamic model, previously suggested for the generation of a highly realistic synthetic ECG. A modified version of this model is used in several Bayesian filters, including the Extended Kalman Filter, Extended Kalman Smoother, and Unscented Kalman Filter. An automatic parameter selection method is also introduced, to facilitate the adaptation of the model parameters to a vast variety of ECGs. This approach is evaluated on several normal ECGs, by artificially adding white and colored Gaussian noises to visually inspected clean ECG recordings, and studying the SNR and morphology of the filter outputs. The results of the study demonstrate superior results compared with conventional ECG denoising approaches such as bandpass filtering, adaptive filtering, and wavelet denoising, over a wide range of ECG SNRs. The method is also successfully evaluated on real nonstationary muscle artifact. This method may therefore serve as an effective framework for the model-based filtering of noisy ECG recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probability, Random Variables, and Stochastic Processes.
Abrahams, J., & Papoulis, A. (1984) · Journal of the American Statistical Association · doi:10.2307/2288754 · Cited by 16,226
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Fundamentals of Statistical Signal Processing: Estimation Theory
Sengijpta, S. K. (1995) · Technometrics · doi:10.1080/00401706.1995.10484391 · Cited by 11,076
De-noising by soft-thresholding
Donoho, D. L. (1995) · IEEE Transactions on Information Theory · doi:10.1109/18.382009 · Cited by 9,619
Probability, Random Variables, and Stochastic Processes
Miller, I. (1966) · Technometrics · doi:10.1080/00401706.1966.10490365 · Cited by 8,452
GELB, A. (1974) · CERN Document Server (European Organization for Nuclear Research) · Cited by 6,405
A new method for the nonlinear transformation of means and covariances in filters and estimators
Julier, S., Uhlmann, J., & Durrant-Whyte, H. F. (2000) · IEEE Transactions on Automatic Control · doi:10.1109/9.847726 · Cited by 3,735
Kalman Filtering and Neural Networks
(2001) · Wiley eBooks · doi:10.1002/0471221546 · Cited by 2,386
A new approach for filtering nonlinear systems
Julier, S. J., Uhlmann, J. K., & Durrant-Whyte, H. F. (2005) · Proceedings of 1995 American Control Conference - ACC'95 · doi:10.1109/acc.1995.529783 · Cited by 1,926
Adaptive Blind Signal and Image Processing: Learning Algorithms and Applications
Cichocki, A., & Amari, S. (2002) · Wiley eBooks · doi:10.1002/0470845899 · Cited by 1,863
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
Global Positioning Systems, Inertial Navigation, and Integration
Grewal, M. S., Weill, L. R., & Andrews, A. P. (2006) · Wiley eBooks · doi:10.1002/0470099720 · Cited by 1,596
The principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242
A dynamical model for generating synthetic electrocardiogram signals
McSharry, P. E., Clifford, G. D., Tarassenko, L., & Smith, L. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808805 · Cited by 1,224
Self-citationApplications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection
Thakor, N. V., & Zhu, Y.-S. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83591 · Cited by 885
Bailey, J. J., Berson, A. S., Garson, A., Horan, L. G., Macfarlane, P. W., Mortara, D. W., & Zywietz, C. (1990) · Circulation · doi:10.1161/01.cir.81.2.730 · Cited by 313
Application of independent component analysis in removing artefacts from the electrocardiogram
He, T., Clifford, G., & Tarassenko, L. (2006) · Neural Computing and Applications · doi:10.1007/s00521-005-0013-y · Cited by 210
Self-citationRemoving artifacts from electrocardiographic signals using independent components analysis
Barros, A. K., Mansour, A., & Ohnishi, N. (1998) · Neurocomputing · doi:10.1016/s0925-2312(98)00056-3 · Cited by 180
Multichannel ECG and Noise Modeling: Application to Maternal and Fetal ECG Signals
Sameni, R., Clifford, G. D., Jutten, C., & Shamsollahi, M. B. (2007) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2007/43407 · Cited by 171
Self-citationLaguna, P., Jané, R., Meste, O., Poon, P. W. F., Caminal, P., Rix, H., & Thakor, N. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.161335 · Cited by 145
ECG noise filtering using wavelets with soft-thresholding methods
Agante, P. M., & de Sa, J. P. M. (2003) · Computers in cardiology · doi:10.1109/cic.1999.826026 · Cited by 131
QRS morphology representation and noise estimation using the Karhunen-Loeve transform
Moody, G. B., & Mark, R. G. (2003) · Computers in cardiology · doi:10.1109/cic.1989.130540 · Cited by 96
Nonlinear noise reduction for electrocardiograms
Schreiber, T., & Kaplan, D. T. (1996) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166148 · Cited by 95
The MIT-BIH Noise Stress Test Database
Moody, G. B., Muldrow, W., & Mark, R. G. (1992) · PhysioNet · doi:10.13026/c2hs3t · Cited by 82
Time-varying analysis of heart rate variability signals with a Kalman smoother algorithm
Tarvainen, M. P., Georgiadis, S., Ranta-aho, P. O., & Karjalainen, P. A. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/3/002 · Cited by 80
Block adaptive filters with deterministic reference inputs for event-related signals: BLMS and BRLS
Olmos, S. C., Sörnmo, L., & Laguna, P. (2002) · IEEE Transactions on Signal Processing · doi:10.1109/78.995066 · Cited by 52
Clifford, G. D., & McSharry, P. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.544525 · Cited by 49
Self-citationIntegrating Data, Models, and Reasoning in Critical Care
Heldt, T., Long, B., Verghese, G. C., Peter Szolovits, B., & Mark, R. G. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259734 · Cited by 48
One-pass training of optimal architecture auto-associativeneuralnetwork for detecting ectopic beats
Clifford, G. D., Tarassenko, L., & Townsend, N. W. (2001) · Electronics Letters · doi:10.1049/el:20010762 · Cited by 46
Self-citationHigh resolution ECG filtering using adaptive Bayesian wavelet shrinkage
Popescu, M., Cristea, P. D., & Bezerianos, A. (2002) · Computers in cardiology · doi:10.1109/cic.1998.731887 · Cited by 29
Cited by
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Denoising of ECG signals based on noise reduction algorithms in EMD and wavelet domains
Kabir, M. A., & Shahnaz, C. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.11.003 · Cited by 444
Zhang, Z., Jung, T.-P., Makeig, S., & Rao, B. D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2226175 · Cited by 340
Xu, K., Jiang, X., Lin, S., Dai, C., & Chen, W. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.2988097 · Cited by 37
Metadata
- Authors
- Sameni, R., Shamsollahi, M. B., Jutten, C., & Clifford, G. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-12
- Volume
- 54
- Issue
- 12
- Pages
- 2172-2185
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2157209869
- Cited by
- 502
- References
- 31
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.