Cited by 37Non-Invasive Vital Sign MonitoringECG Monitoring and AnalysisHeart Rate Variability and Autonomic Control

Stochastic Modeling Based Nonlinear Bayesian Filtering for Photoplethysmography Denoising in Wearable Devices

Xu, Ke, Jiang, Xinyu, Lin, Sijie, Dai, Chenyun, Chen, Wei·2020·IEEE Transactions on Industrial Informatics

Abstract

Photoplethysmography (PPG) has shown its great potential for noninvasive health monitoring, but its application in wearable devices is largely impeded due to its extreme vulnerability to motion artifacts. In this article, we proposed a new stochastic modeling based nonlinear Bayesian filtering framework for the recovery of corrupted PPG waveform under strenuous physical exercise in wearable health-monitoring devices. A deep recurrent neural network was first recruited for accurate cardiac-period segmentation of corrupted PPG signals. Then, a stochastic model was applied to extract waveform details from clean PPG pulses, and was further derived into a system-state space. Following this was an extended Kalman filter using the state-space structured by modeling. The covariance of measurement noise was estimated by motion-related information to adjust it into the real physical environment adaptively. Comparison results with state-of-the-art methods on a wearable-device-based 48-subject data set showed the outstanding performance of the proposed denoising framework, with period-segmentation sensitivity and precision higher than 99.1%, instantaneous heart rate (HR) error lower than 2 beats/min, average HR error down to 1.14 beats/min, and recovery accuracy of waveform details significantly improved (p <; 0.05). This framework is the first PPG denoising strategy that introduces waveform-modeling methods to ensure detail recovery, and a great example of algorithm fusion between stochastic signal processing and emerging deep learning methods for time-sequential biomedical signal processing.

Integrity signals

Registry

Crossref · 10.1109/tii.2020.2988097

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Motion artifacts can be removed from a single PPG signal using techniques such as a periodic moving average filter, waveform synthesis through stochastic modeling, adaptive filtering, and signal decomposition.

    “Motion artifacts can be removed from a single PPG signal using techniques, such as a periodic moving average filter [78], waveform synthesis through stochastic modeling [79], adaptive filtering, and signal decomposition [80].”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [79]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Xu, K., Jiang, X., Lin, S., Dai, C., & Chen, W.
Affiliations
Fudan University (CN)
Venue
IEEE Transactions on Industrial Informatics
Published
2020-11
Volume
16
Issue
11
Pages
7219-7230
ISSN
  • 1551-3203 (ISSN-L)
  • 1941-0050
OpenAlex
W3018261379
Cited by
37
References
39
Citations by year
2026: 5 · 2025: 8 · 2024: 3 · 2023: 7 · 2022: 8 · 2021: 3 · 2020: 3
FWCI
1.65
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Industrial Informatics (publishedVersion)
Funders
  • National Key R and D Program of China (2017YFE0112000)
  • Shanghai Municipal Science and Technology Major Project (2017SHZDZX01)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
photoplethysmography, motion artifacts, wearable health monitoring, nonlinear Bayesian filtering, extended Kalman filter, state-space model, stochastic modeling, deep recurrent neural networks, heart rate estimation, measurement noise covariance estimation, physical activity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review