A New 3-D Finite-Element Model Based on Thin-Film Approximation for Microelectrode Array Recording of Extracellular Action Potential
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A transient finite-element model has been developed to simulate an extracellular action potential recording in a tissue slice by a planar microelectrode array. The thin-film approximation of the active neuron membrane allows the simulation within single finite-element software of the intracellular and extracellular potential fields. In comparison with a compartmental neuron model, it is shown that the thin-film approximation-based model is able to properly represent the neuron bioelectrical behavior in terms of transmembrane current and potential. Moreover, the model is able to simulate extracellular action potential recordings with properties similar to those observed in biological experiments. It is demonstrated that an ideal measurement system model can be used to represent the recording microelectrode, provided that the electronic recording system adapts to the electrode-tissue interface impedance. By comparing it with a point source approximated neuron, it is also shown that the neuron three-dimensional volume should be taken into account to simulate the extracellular action potential recording. Finally, the influence of the electrode size on the signal amplitude is evaluated. This parameter, together with the microelectrode noise, should be taken into account in order to optimize future microelectrode designs in terms of the signal-to-noise ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · cited 1×
“techniques [1]–[ 3 ]. MEAs allow the chronic extracellular recording of spontaneous or evoked activity, in either neural tissues (in vivo or ex vivo, with acute slices or organotypic preparations) or with dissociated neuron cultures [4]–[7].”
BackgroundAn Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Cited by
Cramer, T., Chelli, B., Murgia, M., Barbalinardo, M., Bystrenova, E., de Leeuw, D. M., & Biscarini, F. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp44251a · Cited by 87
Current approaches to model extracellular electrical neural microstimulation
Joucla, S., Glière, A., & Yvert, B. (2014) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2014.00013 · Cited by 78
“Then, we present a “whole finite element” approach allowing the simultaneous calculation of the extracellular and intracellular potentials, by representing the neuronal membrane with a thin-film approximation.”
MethodInfluentialSelf-citationImproved focalization of electrical microstimulation using microelectrode arrays: a modeling study
Joucla, S., & Yvert, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004828 · Cited by 68
Self-citation32.9 nV/rt Hz ${-}$60.6 dB THD Dual-Band Micro-Electrode Array Signal Acquisition IC
Guo, J., Yuan, J., Huang, J., Law, J. K.-Y., Yeung, C.-K., & Chan, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185590 · Cited by 45
Metadata
- Authors
- Moulin, C., Gliere, A., Barbier, D., Joucla, S., Yvert, B., Mailley, P., & Guillemaud, R.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2008-02
- Volume
- 55
- Issue
- 2
- Pages
- 683-692
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2121399822
- Cited by
- 53
- References
- 2
- FWCI
- 1.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New 3-D Finite-Element Model Based on Thin-Film Approximation for Microelectrode Array Recording of Extracellular Action Potential. https://app.cochat.ai/papers/10.1109/tbme.2007.903522
- The paper
- Moulin, C., Gliere, A., Barbier, D., Joucla, S., Yvert, B., Mailley, P., & Guillemaud, R. (2008). A New 3-D Finite-Element Model Based on Thin-Film Approximation for Microelectrode Array Recording of Extracellular Action Potential. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2007.903522
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.