An Integrated-Circuit Approach to Extracellular Microelectrodes
Open accessAbstract
This paper describes a new multielectrode microprobe which utilizes integrated-circuit fabrication techniques to overcome many of the problems associated with conventional microelectrodes. The probe structure consists of an array of gold electrodes which are supported on a silicon carrier and which project beyond the carrier for a distance of about 50 μ to allow a close approach to active neurons. These electrodes are covered with a thin (0.4-μ) layer of silicon dioxide which is selectively removed at the electrode tips using high-resolution photoengraving techniques to define the recording areas precisely. The processing sequence described permits any two-dimensional electrode array to be realized. Interelectrode spacings can be accurately controlled in the range from 10 to 20 μ or larger, and electrode-tip diameters can be as small as 2 μ.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Neuroscience studies commonly place electrodes into specific cortical regions to record neural electrical activity.
“Typical neuroscience studies involve inserting electrodes [10, 90, 144] into specific regions of the cortex to acquire neural electrical activity.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [144]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 459 · see citing works
Gesteland, R. C., Howland, B., Lettvin, J. Y., & Pitts, W. (1959) · Proceedings of the IRE · doi:10.1109/jrproc.1959.287156 · Cited by 302 · see citing works
PHYSICAL TECHNIQUES IN BIOLOGICAL RESEARCH
(1963) · Elsevier eBooks · doi:10.1016/b978-1-4831-6743-5.50006-x · Cited by 143 · see citing works
Terzuolo, C. A., & Araki, T. (1961) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1961.tb35558.x · Cited by 126 · see citing works
Neuronal Activity in Cortical and Thalamic Networks
Verzeano, M., & Negishi, K. (1960) · The Journal of General Physiology · doi:10.1085/jgp.43.6.177 · Cited by 116 · see citing works
Principles of Applied Biomedical Instrumentation
Smale, A. J. (1969) · Electronics and Power · doi:10.1049/ep.1969.0230 · Cited by 102 · see citing works
Electronic apparatus for biological research
Shipton, H. W. (1959) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(59)90137-3 · Cited by 74 · see citing works
Swann, R. G., Mehta, R. R., & Cauge, T. (1967) · Journal of The Electrochemical Society · doi:10.1149/1.2426714 · Cited by 72 · see citing works
Measurement of Bioelectric Potentials With Microelectrodes and Neutralized Input Capacity Amplifiers
Amatniek, E. (1958) · IRE Transactions on Medical Electronics · doi:10.1109/iret-me.1958.5008482 · Cited by 72 · see citing works
Electrical properties of glass microelectrodes
Schanne, O. F., Lavallée, M., Laprade, R., et al. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6459 · Cited by 56 · see citing works
Advances in biomedical engineering and medical physics
Hill, D. W. (1968) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474734 · Cited by 52 · see citing works
A glass-covered platinum microelectrode
Guld, C. (1964) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474628 · Cited by 48 · see citing works
Dipoles of spontaneous activity in the cerebral cortex
Elul, R. (1962) · Experimental Neurology · doi:10.1016/0014-4886(62)90044-4 · Cited by 41 · see citing works
Electrical and Thermal Properties of Double-Barreled Ultra Microelectrodes
Rush, S., Lepeschkin, E., & Brooks, H. O. (1968) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1968.4502542 · Cited by 8 · see citing works
Flagged first, then by citations
Research works printed but not linked: 4
- W. L. Nastuk, Ed. New York: Academic Press, 1964, ch. 2.
- R. C. G. Swann, R. R. Mehta, and T. P. Cauge, "The prepara- tion and properties of thin film silicon-nitrogen compotunds pro- duced by a radio frequency flow discharge reaction," J. Elec- trochem. Soc., vol. 114, pp. 713-717, 1967.
- WV. L. Nastuk, Ed. New Y ork: Academic Press, 1964, ch. 3.
- D. A. Robinson, "The electrical properties of miietal microelec- trodes," Proc. IEEE, vol. 56, pp. 1065-1071, June 1968.
Cited by
Sorted by citations
Novel electrode technologies for neural recordings
Hong, G., & Lieber, C. M. (2019) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0140-6 · Cited by 695 · see citing works
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705 · see citing works
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656 · see citing works
Self-citationA Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580 · see citing works
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504 · see citing works
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384 · see citing works
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310 · see citing works
Self-citationCriteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240 · see citing works
Implantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202 · see citing works
Silicon microsystems for neuroscience and neural prostheses
Wise, K. D. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511497 · Cited by 194 · see citing works
Self-citationEdell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · see citing works
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175 · see citing works
Multiple microelectrode-recording system for human intracortical applications
Ulbert, I., Halgren, E., Heit, G., & Karmos, G. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00330-2 · Cited by 173 · see citing works
The Future of Neuroimplantable Devices: A Materials Science and Regulatory Perspective
Obidin, N., Tasnim, F., & Dagdeviren, C. (2020) · Advanced Materials · doi:10.1002/adma.201901482 · Cited by 126 · see citing works
Brumberg (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00065 · Cited by 114 · see citing works
Thin films and microelectrode arrays for neuroprosthetics
Ordonez, J., Schuettler, M., Boehler, C., Boretius, T., & Stieglitz, T. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.117 · Cited by 118 · see citing works
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113 · see citing works
The future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115 · see citing works
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108 · see citing works
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89 · see citing works
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83 · see citing works
Seidl, K., Herwik, S., Torfs, T., Neves, H. P., Paul, O., & Ruther, P. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2167661 · Cited by 68 · see citing works
Loeb, G. E., Marks, W. B., & Beatty, P. G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442964 · Cited by 46 · see citing works
Computational assessment of neural probe and brain tissue interface under transient motion.
Polanco, M., Bawab, S., & Yoon, H. (2016) · Biosensors · doi:10.3390/bios6020027 · Cited by 36 · see citing works
Recent advances in recording and modulation technologies for next-generation neural interfaces.
Hong, J.-W., Yoon, C., Jo, K., Won, J. H., & Park, S. (2021) · iScience · doi:10.1016/j.isci.2021.103550 · Cited by 25 · see citing works
Recording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array
Byun, D., Cho, S.-J., Lee, B. H., Min, J., Lee, J.-H., & Kim, S. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7493 · Cited by 23 · see citing works
Implantable Device Fabrication and Packaging
Stieglitz, T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_102 · Cited by 7 · see citing works
- Authors
- Wise, K. D., Angell, J. B., & Starr, A.
- Affiliations
- Stanford University (US)
- Stanford Medicine (US)
- ORCID
- Starr, Arnold
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1970-07
- Volume
- BME-17
- Issue
- 3
- Pages
- 238-247
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2053012273
- Cited by
- 544
- References
- 14
- Citations by year
- 2026: 12 · 2025: 28 · 2024: 23 · 2023: 19 · 2022: 29 · 2021: 22 · 2020: 22 · 2019: 28 · 2018: 18 · 2017: 16 · 2016: 16 · 2015: 19 · 2014: 22 · 2013: 24 · 2012: 12
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- integrated circuit fabrication, silicon dioxide etching, photoengraving, electrode spacing, neural recording
- MeSH terms
- Animals, Biomedical Engineering, Cats, Electrodes, Electronics, Medical, Neurophysiology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review