Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 226

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Detector for a Chronic Implantable Atrial Tachyarrhythmia Monitor

Sarkar, S., Ritscher, D., Mehra, R. · 2008 · IEEE Transactions on Biomedical Engineering

Abstract

Continuous long-term monitoring of atrial fibrillation (AF) and tachycardia (AT) is an unmet clinical need, which could be met with a chronically-implanted monitor. Improved therapeutic decisions based on accurate monitoring of parameters, such as daily AF/AT burden (hours/ day) may lead to improvements in clinical outcomes such as reduction in hospitalizations, symptoms, and strokes. This paper describes an AF/AT detector that detects AF as well as AT with an irregular ventricular response, and a supplementary AT detector for AT with more regular ventricular response. Seven databases with significant durations of AF, AT, and sinus rhythm were used to evaluate the performance of the detectors. All patient records with AF (N = 124) were detected by the AF/AT detector to have AF/AT burden with a mean, median, and 75 percentile of absolute error in burden detection of 8.8, 0, and 4 min, respectively. In patients having AF burden (= or > 10 min), the AF/AT detector was found to have burden accuracy within 20% of true burden in 96% of patients. The specificity was 94%, defined as follows: in patient records without AF/AT (N = 174), the percentage with AF/AT burden = or < 10 min in the 24-h recordings. The AF/AT detector underestimatesAT burden, thus degrading performance, in patients with significant amounts of AT with more regular ventricular response. The supplementary AT detector reduces the underestimation of AT while overestimating burden in patients without a significant amount of AT. The detectors described here could be implemented in an implantable monitor for accurate long-term AF/AT monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2007.903707

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 226

Metadata

Authors
Sarkar, S., Ritscher, D., & Mehra, R.
Venue
IEEE Transactions on Biomedical Engineering
Published
2008-03
Volume
55
Issue
3
Pages
1219-1224
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2155103273
Cited by
226
References
1
FWCI
5.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.