xDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) is a communication system that allows to control a computer or any other device thanks to the brain activity. The BCI described in this paper is based on the P300 speller BCI paradigm introduced by Farwell and Donchin . An unsupervised algorithm is proposed to enhance P300 evoked potentials by estimating spatial filters; the raw EEG signals are then projected into the estimated signal subspace. Data recorded on three subjects were used to evaluate the proposed method. The results, which are presented using a Bayesian linear discriminant analysis classifier , show that the proposed method is efficient and accurate.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“They can enhance the P300 component and reduce the data dimensions, which is very suitable to our needs.”
From Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier (2020) · cites this paper as [23]
In the citing paper
“They can enhance the P300 component and reduce the data dimensions, which is very suitable to our needs.”
From Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier (2020) · cites this paper as [23]
In the citing paper
“as the xDAWN estimates the spatial filters by maximizing the difference between the averaged signals of the corresponding category and the whole EEG data[28].”
From A Cascade xDAWN EEGNet Structure for Unified Visual-Evoked Related Potential Detection (2024) · cites this paper as [28]
In the citing paper
“Unmixing of these global patterns using a number of spatial filters is therefore typically applied to the whole set of relevant electrodes as a basic step in many successful examples of EEG decoding [Ang et al., 2008; Blankertz et al., 2008; Rivet et al., 2009].”
From Deep learning with convolutional neural networks for EEG decoding and visualization (2017) · cites this paper as Rivet et al., 2009
In the citing paper
“For all ERP-based data analyses (P300, ERN, MRCP) the traditional approach is the approach which won the Kaggle BCI Competition (code and documentation at http://github.com/alexandrebarachant/bci-challenge-ner-2015), which uses a combination of xDAWN Spatial Filtering [83], Riemannian Geometry [84,85], channel subset selection and L 1 feature regularization”
From EEGNet: a compact convolutional neural network for EEG-based brain-computer interfaces (2018) · cites this paper as [84]
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“See [ 3 ] for a more detailed review of BCIs.”
BackgroundMethodIndependent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
RELATIONS BETWEEN TWO SETS OF VARIATES
HOTELLING, H. (1936) · Biometrika · doi:10.1093/biomet/28.3-4.321 · Cited by 5,263
Independent Component Analysis
Hyvärinen, A., Karhunen, J., & Oja, E. (2001) · Wiley eBooks · doi:10.1002/0471221317 · Cited by 5,007
MacKay, D. J. C. (1992) · Neural Computation · doi:10.1162/neco.1992.4.3.415 · Cited by 4,388 · cited 1×
“Among the proposed classifiers for BCIs, Bayesian linear discriminant analysis (BLDA) [2], [26] is chosen since it was proved to be efficient and was fully automatic (i.e., no hyper-parameters to adjust) [2].”
MethodAn introduction to kernel-based learning algorithms
Muller, K.-R., Mika, S., Ratsch, G., Tsuda, K., & Scholkopf, B. (2001) · IEEE Transactions on Neural Networks · doi:10.1109/72.914517 · Cited by 3,473
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 2×
“However, these repetitions decrease the number of symbols spelled per minute, e.g., with 15 repetitions, only two characters are typically spelled per minute [1], [8].”
BackgroundMethodBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024 · cited 1×
“The EEG was collected and stored using the BCI2000 system with the P300 speller scenario [24].”
MethodBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Self-citation
Research works printed but not linked: 2
- rivet, 2007, extraction de potentiels voqus p300 pour les interfaces cerveau-machine, Proc GRETSI, 625
- golub, 1996, Matrix Computation
Cited by
Items 301–400 of 573
Collaborative Brain-Computer Interface for Human Interest Detection in Complex and Dynamic Settings
Solon, A. J., Gordon, S. M., McDaniel, J., & Lawhern, V. J. (2018) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2018.00172 · Cited by 7
“Today, individual BCI designs rarely use averaged ERP approaches, instead opting for single-trial classification of the EEG data [18,19].”
MethodP300 Harmonies: A Brain-Computer Musical Interface
Vamvakousis, Z., & Ramírez, R. (2014) · University of Michigan Library Repository · doi:10.5281/zenodo.850666 · Cited by 8
Enhancing multi-paradigm EEG signal classification in cross-subject settings using optimal transport
Morvay, B. T., Torma, S., Pitrik, J., & Szegletes, L. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108892 · Cited by 6
A Review of EEG Artifact Removal Techniques for Brain-Computer Interface
Dhole, P. V., Chaudhary, D. G., Dhangar, V. D., Shejul, S. D., Datwase, S. S., & Gawali, B. W. (2025) · SN Computer Science · doi:10.1007/s42979-025-04592-z · Cited by 6
“It functions through spatial filtering to enhance the SNR of the EEG data for the particular event targeted [81, 82].”
Deep Transformer Network and CNN Model with About 200k Parameters to Classify P300 EEG Signal
Otarbay, Z., Orazaly, M., Assaiyn, Y., Chagirov, S., Pernebayev, S., & Tleuzhan, A. (2023) · IEEE International Conference on Smart Information Systems and Technologies (SIST) · doi:10.1109/sist58284.2023.10223580 · Cited by 6
The Riemannian Means Field Classifier for EEG-Based BCI Data
Andreev, A., Cattan, G., & Congedo, M. (2025) · Sensors · doi:10.3390/s25072305 · Cited by 9
“For P300 data, we employ the Xdawn spatial filter [24,25], which is the equivalent of the CSP (which applies to event-related (de)synchronization) for event-related potentials data.”
Abdulwahab, S., Khleaf, H. K., & Jassim, M. H. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1973/1/012056 · Cited by 6
“It reaches an accuracy of 84% for two class problem.[10] used Common Spatial Pattern (CSP) filtering along with LDA to reach a maximum accuracy of 99%.”
BackgroundMortier, S., Turkeš, R., Winne, J. D., Ransbeeck, W. V., Botteldooren, D. B., Devos, P., Latré, S., Leman, M., & Verdonck, T. (2023) · Sensors · doi:10.3390/s23239588 · Cited by 6
“First, we applied the xDAWN pipeline, which has demonstrated significant success in several EEG classification tasks [29,30].”
MethodInfluentialAutomatic control of reactive brain computer interfaces
Tufvesson, P., & Heskebeck, F. (2024) · IFAC Journal of Systems and Control · doi:10.1016/j.ifacsc.2024.100251 · Cited by 6
Tang, C. L., Gao, T., Wang, G., & Chen, B. (2024) · Cognitive Neurodynamics · doi:10.1007/s11571-024-10085-1 · Cited by 6
“The xDawn algorithm (Rivet et al. 2009) not only reduces the dimensionality of the signal but also increases the signal-to-noise ratio.”
Group-member selection for RSVP-based collaborative brain-computer interfaces
Si, Y., Wang, Z., Xu, G., Wang, Z., Xu, T., Zhou, T., & Hu, H. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1402154 · Cited by 6
You, W., Yang, R., Qin, C., Huang, M., & Wang, Z. (2025) · IEEE Transactions on Emerging Topics in Computational Intelligence · doi:10.1109/tetci.2025.3577504 · Cited by 9
“(cid:2) XDAWN is a spatial filtering method designed to improve the signal-to-noise ratio of event-related potential (ERP) responses [31], enhancing target responses by emphasizing them over non-target responses.”
An Adaptive And Efficient Spatial Filter For Event-Related Potentials
Ghaderi, F., & Straube, S. (2013) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.43579 · Cited by 6
Cecotti, H., Barachant, A., King, J.-R., Sánchez‐Bornot, J. M., & Prasad, G. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037848 · Cited by 6
“The XdawnCov pipeline is similar to ERPCov, except that a Xdawn spatial filtering [16], [17] is applied before the covariance estimation in order to increase the SNR of the ERP response.”
MethodChanges in event-related potential functional networks predict traumatic brain injury in piglets
Atlan, L. S., Lan, I. S., Smith, C., & Margulies, S. S. (2018) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2018.05.013 · Cited by 6
“The XDawn and XDawnCov techniques have both been successfully used to discriminate between ERP responses to different visual cues (Barachant et al., 2012; Rivet, 2009, 2011).”
MethodAnalyzing P300 Distractors for Target Reconstruction
McDaniel, J. R., Gordon, S. M., Solon, A. J., & Lawhern, V. J. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512854 · Cited by 8
“We compare the performance of our generalized BCI model to two well-proven user- and task-specific BCI models— Hierarchical Discriminant Components Analysis (HDCA) [19], and xDAWN [20]—which we trained using block-wise 5-fold cross-validation.”
MethodWireless Stimulus-on-Device Design for Novel P300 Hybrid Brain-Computer Interface Applications
Kuo, C., Chen, H., Chou, H.-C., Chen, P.-N., & Kuo, Y.-C. (2018) · Computational Intelligence and Neuroscience · doi:10.1155/2018/2301804 · Cited by 7
“Viewing proposed literatures, SVM [14–16], Linear Discriminant Analysis (LDA) [17–20], Bayesian Analysis [21–25], and Artificial Neural Network (ANN) [26–30] classifiers were discussed.”
BackgroundSchembri, P., Pelc, M., & Ma, J. (2019) · Computer Science and Electronic Engineering Conference · doi:10.1109/ceec47804.2019.8974315 · Cited by 6
Gupta, E., & Sivakumar, R. (2022) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn55064.2022.9892115 · Cited by 6
“…have been proposed throughout the literature, spanning different techniques for artifact removal [13] [14], using improved spatial filters [15], combining EEG with fNIRS to compensate for low spatial resolution [16], using domain adaptation techniques for better signal generalization…”
MethodVerbal Communication through Brain Computer Interfaces
Clerc, M., Mattout, J., Maby, E., Devlaminck, D., Papadopoulo, T., Guy, V., & Desnuelle, C. (2013) · Cited by 6
Goljahani, A., D’Avanzo, C., Silvoni, S., Tonin, P., Piccione, F., & Sparacino, G. (2014) · Computational and Mathematical Methods in Medicine · doi:10.1155/2014/731046 · Cited by 7
“To this aim, BCI investigators have studied ad hoc stimulation schemes [20, 23–25], optimal channel sets [14, 26], channel selection methods [27, 28], classification algorithms [29–32], and spatial filtering approaches [18, 33–35].”
Augmented Iterations: Integrating Neural Activity in Evolutionary Computation for Design
Cutellic, P., & Lotte, F. (2013) · Research Repository (Delft University of Technology) · Cited by 6
An Efficient Decoder for the Recognition of Event-Related Potentials in High-Density MEG Recordings
Reichert, C., Dürschmid, S., Kruse, R., & Hinrichs, H. (2016) · Computers · doi:10.3390/computers5020005 · Cited by 6
“, independent component analysis (ICA) [3], common spatial patterns (CSP) [4], spatial whitening [5], canonical correlation analysis (CCA) [6], and others [7,8].”
BackgroundERP Detection Based on Smoothness Priors
Mobaien, A., Boostani, R., Mohammadi, M., & Sanei, S. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3204506 · Cited by 6
“From [30], the first filters are mostly contributed to ERPs while the last ones mostly extract noise.”
BackgroundMethodInfluentialMari, T., Henderson, J., Ali, H. H., Hewitt, D., Brown, C. A., Stančák, A., & Fallon, N. B. (2023) · BMC Neuroscience · doi:10.1186/s12868-023-00819-y · Cited by 6
“Indeed, ML-EEG research often implements spatial filters to improve the signal-to-noise ratio and classification performance [77, 78].”
A Plug-and-Play P300-Based BCI With Zero-Training Application
Kim, J., & Kim, S.-P. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3603979 · Cited by 5
“On the signal processing side, recent advances such as xDAWN spatial filtering [44], Riemannian geometry-based features [34], and deep learning classifiers [45] have also shown promise in improving performance across users.”
Periodic Spatial Filter for Single Trial Classification of Event Related Brain Activity
Ghaderi, F., & Kirchner, E. A. (2013) · Biomedical Engineering · doi:10.2316/p.2013.791-110 · Cited by 5
“The results, reported in [8], show the outstanding performance of the xDAWN method compared with the other methods.”
MethodResultInfluentialWang, X., Dang, M., Yang, K., Cui, X., Zhang, D., & Chen, C. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106583 · Cited by 7
Files, B. T., & Marathe, A. R. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.11.003 · Cited by 5
Low channel count montages using sensor tying for VEP-based BCI
Ahmadi, S., Borhanazad, M., Tump, D., Farquhar, J. D. R., & Desain, P. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4057 · Cited by 5
“…Mugler et al 2010), SCPs (Hinterberger et al 2004, Iversen et al 2008) and motor imagery (ERS/ERD) (Pfurtscheller and Neuper 2001, Pfurtscheller et al 2006) have weaker response which is more distributed over the head causing much lower spatial frequency (Hinterberger et al 2004, Rivet et al 2009).”
BackgroundAsynchronous Classification of Error-Related Potentials in Human-Robot Interaction
Kim, S. K., Maurus, M., Trampler, M., Tabie, M., & Kirchner, E. A. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-35602-5_7 · Cited by 5
“The xDAWN spatial filter [24] was used to enhance the signal to signal-plus-noise ratio and 7 pseudo channels were retained after spatial filtering.”
MethodDetection of tactile-based error-related potentials (ErrPs) in human-robot interaction
Kim, S. K., & Kirchner, E. A. (2023) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2023.1297990 · Cited by 7
Hairston, W. D., & Lawhern, V. J. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-20816-9_22 · Cited by 5
“Collectively this technique will be referred to as XDBLDA; a full description can be found in [24 – 26]. xDAWN spatial fi ltering results in a set of spatial fi lters that are rank ordered such that the highest rank fi lters maximize the signal to signal plus noise ratio in the EEG signals.”
MethodHuang, H.-P., Liu, Y.-H., Lin, W., Kang, Z.-H., Cheng, C.-A., & Huang, T.-H. (2015) · International Journal of Automation and Smart Technology · doi:10.5875/ausmt.v5i2.518 · Cited by 5
“Based on the LDA, a Bayesian LDA (BLDA) classifier was further proposed in [7] and has been used in a P300 speller paradigm [8].”
MethodKirchner, E. A., & Kim, S. K. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00188 · Cited by 5
“For both binary and multi-class classification, the xDAWN (Rivet et al., 2009) was used as a spatial filter to enhance the signalto-noise ratio, since it is especially suited for the analysis of EEG activity in the ERP domain (Rivet et al.”
MethodParallel Computing Sparse Wavelet Feature Extraction for P300 Speller BCI
Huang, Z., Li, M., & Ma, Y. (2018) · Computational and Mathematical Methods in Medicine · doi:10.1155/2018/4089021 · Cited by 5
“Since WF does not focus on classifier but feature extraction, WF, downsampling (DS), and xDAWN (xD) [27] were, respectively, combined with the stepwise linear discriminant analysis (SWLDA), the default classifier in BCI2000, to classify the EEG epochs in the test data sets.”
MethodKirchner, E. A., & Kim, S. K. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717041 · Cited by 5
“The xDAWN [21] was used as a spatial filter to enhance the signal-to-signal plus noise ratio.”
MethodSchembri, P., Pelc, M., & Ma, J. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857093 · Cited by 5
Simar, C., Petit, R., Bozga, N., Leroy, A., Cebolla, A.-M., Petieau, M., Bontempi, G., & Cheron, G. A. (2022) · PLoS ONE · doi:10.1371/journal.pone.0262417 · Cited by 5
“For this, we use a classification pipeline based on xDAWN spatial filtering [33] and Riemannian geometry applied to single-trial EEG data recorded during a visual stimulation.”
MethodBrain-Machine Interface for Mechanical Ventilation Using Respiratory-Related Evoked Potential
Chevallier, S., Bao, G., Hammami, M., Marlats, F., Mayaud, L., Annane, D., Lofaso, F., & Azabou, É. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01424-7_65 · Cited by 5
“When dealing with evoked potentials, XDAWN filters are a robust and widely employed algorithm [20].”
Transfer Learning for Brain-Computer Interfaces: A Complete PipelinePreprint
Wu, D., Peng, R., Huang, J., & Zeng, Z. (2020) · arXiv (Cornell University) · Cited by 6
Colafiglio, T., Lofù, D., Sorino, P., Festa, F., Noia, T. D., & Sciascio, E. D. (2023) · IEEE EUROCON - International Conference on Computer as a Tool (EUROCON) · doi:10.1109/eurocon56442.2023.10198964 · Cited by 4
“XDAWN [20] algorithm present in the MNE framework is applied.”
MethodInfluentialPost-Training Quantization in Brain-Computer Interfaces Based on Event-Related Potential Detection
Cecotti, H., Dhaliwal, D., Singh, H., & Meena, Y. K. (2024) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc54092.2024.10831138 · Cited by 4
“For single-trial detection (target vs. non-target), we consider the combination of the xDAWN spatial filtering approach with the Bayesian Linear Discriminant Analysis classifier (BLDA) [11]–[13].”
Gouy‐Pailler, C., Sébag, M., Larue, A., & Souloumiac, A. (2011) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.20285 · Cited by 4
“This relative success is mainly explained by the stability of the neurophysiological response called P300, which allows simplifications of the signal processing and machine learning algorithms employed to decode EEG signals (see Rivet et al., 2009 for an efficient example of such algorithms).”
BackgroundSelf-citationSVM feature selection for multidimensional EEG data
Jrad, N., Phlypo, R., & Congedo, M. (2011) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2011.5946520 · Cited by 4
Backtransformation: a new representation of data processing chains with a scalar decision function
Krell, M. M., & Straube, S. (2015) · Advances in Data Analysis and Classification · doi:10.1007/s11634-015-0229-3 · Cited by 4
“…analysis (Lagerlund et al. 1997; Rivet et al. 2009; Abdi and Williams 2010, PCA), and independent component analysis (Jutten and Herault 1991; Rivet et al. 2009, ICA) for spatial filtering, the space component of the data is taken as feature component for these algorithms and the time…”
BackgroundMethodInfluentialA robust framework for optimum feature extraction and recognition of P300 from raw EEG
Shah, S., Kumar, A., Kumar, R., & Dey, N. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-815370-3.00002-5 · Cited by 4
EEG Emotion Detection Using Multi-Model Classification
Abdullah, M. A., & Christensen, L. R. (2018) · International Conference on Bioinformatics and Systems Biology (BSB) · doi:10.1109/bsb.2018.8770695 · Cited by 4
“1) xDAWN [9][10]: The proposed filtering in [9] is used to provide the best SNR Signal to noise ratio, which takin into account the signal and the ration as opposed to PCA (Principal component analysis) which only taking into account the signal.”
MethodP300-Based Partial Face Recognition With xDAWN Spatial Filter and Covariance Matrix
Chanpornpakdi, I., & Tanaka, T. (2023) · International Technical Conference on Circuits/Systems, Computers and Communications (ITC-CSCC) · doi:10.1109/itc-cscc58803.2023.10212494 · Cited by 4
“The combination of the xDAWN filter and support vector machine (SVM) was suggested as a suitable model for face cognition [5]. xDAWN is the spatial filter which aims to maximizes the signal-to-signal-plus-noise (SSNR) [8, 9].”
BackgroundWho is WithMe? EEG features for attention in a visual task, with auditory and rhythmic support
Turkeš, R., Mortier, S., Winne, J. D., Botteldooren, D. B., Devos, P., Latré, S., & Verdonck, T. (2025) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1434444 · Cited by 4
“It consists of applying xDAWN spatial filters (Rivet et al., 2009), calculating covariance matrix between the EEG channels to encode their statistical dependencies (Barachant and Congedo, 2014; Congedo et al., 2013), selecting the channels via Riemannian Geometry (RG) (Barachant and Bonnet, 2011),…”
Wang, D., Shi, J., Liu, M., Han, W., Bi, L., & Fei, W. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.128189 · Cited by 4
A synchronization method for wireless acquisition systems, application to brain computer interfaces
Foerster, M., Bonnet, S., van Langhenhove, A., Porcherot, J., & Charvet, G. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609629 · Cited by 4
EEG-based target detection during a multi-rapid serial visual presentation
Lin, Z., Zeng, Y., Wang, X., Wu, Q., & Yan, B. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008412 · Cited by 4
“al[6, 7] proposed the xDawn algorithm, which was designed to maximize the difference in signal-to-noise ratio between target and non-target classes.”
MethodEnsemble of Convolutional Neural Networks for P300 Speller in Brain Computer Interface
Shan, H., Liu, Y., & Stefanov, T. P. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-30490-4_31 · Cited by 4
“For example, Rivet [22] enhances the P300 potentials.”
P300-based brain–computer interface for communication and control
Mendoza-Montoya, O., Antelis, J. M., & Delijorge, J. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-820125-1.00026-9 · Cited by 4
Sandra, R., Jutten, C., & Congedo, M. (2012) · Machine learning for signal processing ... · doi:10.1109/mlsp.2012.6349740 · Cited by 4
“Filtering was done using xDAWN algorithm [14], [15].”
MethodImpact of the time segment analysis for P300 detection with spatial filtering
Cecotti, H., Phlypo, R., Rivet, B., Congedo, M., Maby, E., & Mattout, J. (2010) · International Symposium on Applied Sciences in Biomedical and Communication Technologies · doi:10.1109/isabel.2010.5702917 · Cited by 5
“The spatial filtering method that is considered in this paper is based on the xDAWN algorithm [12], [13].”
MethodSelf-citationMari, T., Ali, H. H., Pacinotti, L., Powsey, S., & Fallon, N. B. (2025) · Cognitive Affective & Behavioral Neuroscience · doi:10.3758/s13415-025-01268-2 · Cited by 5
“Enhanced feature engineering and spatial filtering have been shown to increase the signal-to-noise ratio of EEG and ML performance (Blankertz et al., 2008; Rashid et al., 2020; Rivet et al., 2009; Singh & Krishnan, 2023).”
Novel sequential BCI speller based on ERPs and event-related slow cortical potentials
Poli, R., Mercimek, A. C. C., & Cinel, C. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/add772 · Cited by 3
“Our classification pipeline starts with the xDAWN algorithm [89] which is a spatial filter that optimises the distinction between the ERPs associated to target and non-target stimuli.”
Gomel, J., Torre, J. J., Cimarosto, P., Castillos, K. C., & Dehais, F. (2025) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc58881.2025.11342868 · Cited by 3
“To reduce dimensionality and enhance evoked potentials, the xDAWN spatial filtering method was applied to the covariance matrices [10] using four spatial filters.”
Coadapt P300 Speller: Optimized Flashing Sequences And Online Learning
Thomas, E. M., Daucé, E., Devlaminck, D., Mah, L., Carpentier, A., Munos, R., Perrin, M., Maby, E., Mattout, J., Papadopoulo, T., et al. (2014) · HAL · doi:10.3217/978-3-85125-378-8-51 · Cited by 3
A P300-based BCI classification algorithm using median filtering and Bayesian feature extraction
Li, X., Wang, F., Chen, X., & Ward, R. K. (2012) · IEEE International Workshop on Multimedia Signal Processing (MMSP) · doi:10.1109/mmsp.2012.6343459 · Cited by 3
“Conventional filtering methods are often employed to extract clear P300 signals, but they may also filter the desired signals [4]-[6].”
MethodJoint spatial and spectral filter estimation for single trial detection of event related potentials
Ghaderi, F. (2013) · Machine learning for signal processing ... · doi:10.1109/mlsp.2013.6661938 · Cited by 3
“The xDAWN method [5], maximizes the signal (ERPs) to signal plus noise (ongoing EEG, artifacts and measurement interferences) ratio.”
MethodComparing EEG Artifact Detection Methods for Real-World BCI
Nonte, M. W., Hairston, W., & Gordon, S. M. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-39955-3_9 · Cited by 3
Window-Adjusted Common Spatial Pattern for Detecting Error-Related Potentials in P300 BCI
Huang, Z., Li, M., Zheng, W., Wu, Y., Jiang, K., & Zheng, H. (2023) · Neural Processing Letters · doi:10.1007/s11063-023-11353-7 · Cited by 3
“Originally, xDAWN was proposed to enhance P300 evoked potentials in BCI [28].”
BackgroundMethodInfluentialExternal validation of EEG-based machine learning models for continuous pain prediction
Mari, T., Henderson, J., Ali, S. H., Hewitt, D., Brown, C. A., Stančák, A., & Fallon, N. B. (2026) · Journal of Pain · doi:10.1016/j.jpain.2026.106416 · Cited by 3
Automatic ERP classification in EEG recordings from task-related independent components
Zakeri, Z., Samadi, M. R. H., Cooke, N. J., & Jančovič, P. (2016) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2016.7455891 · Cited by 3
“Unfortunately, although ICA potentially separates the brain sources from artefactual sources, it does not provide information about labelling the ICs.”
BackgroundA periodic spatio-spectral filter for event-related potentials
Ghaderi, F., Kim, S. K., & Kirchner, E. A. (2016) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.10.004 · Cited by 3
Brain computer interface communicator: A response to auditory stimuli experiment
Jadav, G. M., Batistić, L., Vlahinić, S., & Vrankić, M. (2017) · International Convention on Information and Communication Technology, Electronics and Microelectronics · doi:10.23919/mipro.2017.7973461 · Cited by 3
“which are used as spatial filter coefficients i Û [6].”
MethodSchembri, P., Pelc, M., & Ma, J. (2020) · Computers · doi:10.3390/computers9030068 · Cited by 3
“The xDAWN expression, utilized in OpenVIBE, which has to be maximized, varies marginally from the original xDAWN (Rivet et al., 2009) formula where the numerator includes only the average of the target signals.”
BackgroundMethodInfluentialUnsupervised MEG classification by Riemannian Geometry and class centroid matching
Ye, H., Yu, T., Liu, S., & Huang, Z. (2020) · International Conference on Artificial Intelligence and Computer Engineering (ICAICE) · doi:10.1109/icaice51518.2020.00090 · Cited by 4
van den Berg, B., Vanwinsen, L., Jansen, N., & Buitenweg, J. R. (2022) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2022.109580 · Cited by 3
Kumar, A., Gao, L., Li, J., Ma, J., Fu, J., Gu, X., Mahmoud, S. S., & Fang, Q. (2022) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2022.837119 · Cited by 3
“The epochs were spatially filtered using the xDAWN spatial filtering algorithm (Rivet et al., 2009; Congedo et al., 2013).”
MethodEarly Predictability of Grasping Movements by Neurofunctional Representations: A Feasibility Study
Jakubowitz, E., Feist, T., Obermeier, A., Gempfer, C., Hurschler, C., Windhagen, H. J., & Laves, M.-H. (2023) · Applied Sciences · doi:10.3390/app13095728 · Cited by 3
Real-time Bayesian Control of Reactive Brain Computer Interfaces
Tufvesson, P., Nilsson, M. G., Soltesz, K., & Bernhardsson, B. (2023) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2023.10.1612 · Cited by 3
Efficient Brain-Computer Interface for Attention Detection in Health Care Industry
Sharmila, M., Manjula, M., Yogesh, B. M., Keerthana, S., Vijayakumar, P., & Selvam, N. (2023) · International Conference on Self Sustainable Artificial Intelligence Systems (ICSSAS) · doi:10.1109/icssas57918.2023.10331655 · Cited by 3
A generic error-related potential classifier based on simulated subjects
Fidêncio, A. X., Klaes, C., & Iossifidis, I. (2024) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2024.1390714 · Cited by 4
“After spatial-temporal filtering using xDAWN (Rivet et al., 2009) and time-domain features extraction, a linear Support Vector Machine (SVM) classifier was trained.”
MethodAn improved SVM-based real-time P300 speller for brain-computer interface
Liu, Y.-H., Weng, J. T., Kang, Z.-H., Teng, J., & Huang, H. (2010) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2010.5642304 · Cited by 3
Efficient recognition of event-related potentials in high-density MEG recordings
Reichert, C., Dürschmid, S., Hinrichs, H., & Kruse, R. (2015) · Computer Science and Electronic Engineering Conference · doi:10.1109/ceec.2015.7332704 · Cited by 3
“independent component analysis (ICA) [3], common spatial patterns (CSP) [4], spatial whitening [5], canonical correlation analysis (CCA) [6], and others [7], [8].”
BackgroundDaucé, E., Proix, T., & Ralaivola, L. (2015) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2015.7280686 · Cited by 3
“…like controlling a pointer on a screen using motor imagery (the "Graz" task [3]), text typing using event-related potentials ("P300" speller) [1], "brain switch" [4], etc., with corresponding dedicated pre-processing [5], [6], [7] and classification and/or regression techniques [3], [8], [9].”
MethodCecotti, H., Eckstein, M. P., & Giesbrecht, B. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943832 · Cited by 3
“In this method, spatial filters are obtained through the Rayleigh quotient by maximizing the signal-to-signal plus noise ratio.”
MethodSoltanpour, M., Faez, K., Sharifian, S., & Pourahmadi, V. (2016) · International Conference on Signal Processing and Intelligent Systems (ICSPIS) · doi:10.1109/icspis.2016.7869850 · Cited by 3
“In [13], [14] mutual information is used for channel selection.”
BackgroundReducing Calibration Time for the P300 Brain-Computer Interface Speller
Cecotti, H., Saint-Ellier, G., Rivet, B., Perrin, M., Maby, E., & Mattout, J. (2010) · HAL · Cited by 3
Self-citationDenoising and Time-Window Selection Using Wavelet-Based Semblance for Improving ERP Detection
Saavedra, C., & Bougrain, L. (2013) · doi:10.3217/978-3-85125-260-6-150 · Cited by 3
Liu, Y., Yu, T., & Li, Y. (2019) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2019.8834085 · Cited by 3
“To increase the signal-to-noise ratio, an algorithm derived from the xDawn algorithm was employed for spatial filtering [13].”
MethodSpatial filters for auditory evoked potentials transfer between different experimental conditions
Sosulski, J., & Tangermann, M. (2019) · FreiDok plus (Universitätsbibliothek Freiburg) · doi:10.3217/978-3-85125-682-6-50 · Cited by 3
“For each subject and SOA condition we trained an individual xDAWN filter in the interval of 0 ms to 600 ms as suggested in [9].”
BackgroundMethodInfluentialCross-Subject MEG Decoding Using 3D Convolutional Neural Networks
Huang, Z., & Yu, T. (2019) · WRC Symposium on Advanced Robotics and Automation (WRC SARA) · doi:10.1109/wrc-sara.2019.8931958 · Cited by 4
“We used xDawn to enhance the signal to noise ratio and to reduce the dimension of the signal[17].”
MethodOFFLINE LINEAR DISCRIMINANT ANALYSIS CLASSFICATION OF TWO CLASS EEG SIGNALS
Abdulkareem, H. A., & Al-Faiz, M. Z. (2019) · Iraqi Journal of Information & Communications Technology · doi:10.31987/ijict.2.3.71 · Cited by 6
“[5] used Common Spatial Pattern (CSP) filtering along with LDA to reach a maximum accuracy of 99%.”
MethodQuick breast cancer detection via classification of evoked EEG potentials in the mammologist's brain
Sulimova, V. V., Windridge, D., Bukhonov, S., Mottl, V., & Krasotkina, O. (2019) · International Multi-Conference on Engineering, Computer and Information Sciences (SIBIRCON) · doi:10.1109/sibircon48586.2019.8958286 · Cited by 3
“…by Principal Component Analysis [18], Independent Component Analysis [19], spatial filtering for maximizing the signal-to-signal-plus-noise ratio between target/non-target stim-uli classes [20], determination of the optimal linear combination of data from differ-ent electrodes [11] and so on [16].”
MethodLi, T., & Huang, Z. (2020) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei51763.2020.9263583 · Cited by 3
“We defined this approach as Adaptive Temporal Pattern Extraction (ATPE), which performs better than xDAWN [10], Principal Components Analysis (PCA) [11] and Independent Components Analysis (ICA) [12] in Accuracy (Acc), Area Under the Curve (AUC) and F1-score (F1).”
MethodMNE: Software for Acquiring, Processing,and Visualizing MEG/EEG Data
Esch, L., Dinh, C., Larson, E., Engemann, D. A., Jas, M., Khan, S., Gramfort, A., & Hämäläinen, M. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_59-1 · Cited by 8
Hyper-Accelerated Learning for Brain-Computer Interfaces via Partial Target-Aware Optimal Transport
Gupta, E., Chen, C.-Y., & Sivakumar, R. (2023) · doi:10.1145/3615592.3616853 · Cited by 3
“The state-of-theart method for cross-user ErrP detection uses XDAWN spatial filtering [10] and Riemannian Geometry [11].”
MethodCoadaptation cerveau machine pour une interaction optimale : application au P300-Speller
Perrin, M. (2012) · theses.fr (ABES) · doi:10.70675/fbba5655z6100z49cfzbfa4zfb1483c82ea6 · Cited by 8
Bayesian Signal Matching for Transfer Learning in ERP-Based Brain Computer Interface
Ma, T., Huggins, J. E., & Kang, J. (2025) · Journal of the American Statistical Association · doi:10.1080/01621459.2025.2563189 · Cited by 3
“Since the SNR of EEG signals is typically low, we further applied the xDAWN filter to enhance the evoked potentials (Rivet et al. 2009).”
InfluentialRiemannian Prediction of Anatomical Diagnoses in Congenital Heart Disease Based on 12-Lead ECGS
Alkan, M., VELDTMAN, G. R., & Deligianni, F. (2024) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi56570.2024.10635164 · Cited by 2
“We applied spatial filtering F to enhance the signal-to-noise ratio and remove the artifacts [5].”
MethodLi, H., Liu, Y., Liu, K., Qu, Y., Dai, W., Tang, J., & Zhou, Z. (2025) · Neural Networks · doi:10.1016/j.neunet.2025.107578 · Cited by 2
Mao, J., Wei, W., Li, X., Qiu, S., & He, H. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3607814 · Cited by 2
“In contrast, xDAWN [36] optimized target SNR using data from a P300-speller task (three subjects; 20k samples/subject).”
Near-invisible c-VEP-based passive BCI for mental workload monitoring
Cimarosto, P., Sebastien, V., Castillos, K. C., Torre, J. J., Roy, R. N., & Dehais, F. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae4ff6 · Cited by 3
“To improve the SNR of the captured ERP response to the flashes of the StAR c-VEP, and therefore the performance of ERP-based BCI [45], the windows were reduced using xDAWN spatial filtering, selecting the 4 highest-ranking components.”
Avital, N., Sadan, D., Shikly, M., & Malka, D. (2026) · Machine Learning and Knowledge Extraction · doi:10.3390/make8070171 · Cited by 2
Concurrent control of natural and robotic limbs through a tactile-encoded brain-computer interface
Jia, T., Yang, X., McGeady, C., Li, Y., Lin, J. F., Ho, K. S., Pan, F., Ji, L., Li, C., & Farina, D. (2026) · Nature Communications · doi:10.1038/s41467-026-75213-3 · Cited by 3
Metadata
- Authors
- Rivet, B., Souloumiac, A., Attina, V., & Gibert, G.
- Affiliations
- Institut polytechnique de Grenoble (FR)
- Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR)
- Lyon 1 Université (FR)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2009-08
- Volume
- 56
- Issue
- 8
- Pages
- 2035-2043
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2104063964
- Cited by
- 537
- References
- 29
- Citations by year
- 2026: 21 · 2025: 37 · 2024: 50 · 2023: 43 · 2022: 31 · 2021: 37 · 2020: 44 · 2019: 35 · 2018: 38 · 2017: 32 · 2016: 36 · 2015: 33 · 2014: 23 · 2013: 34 · 2012: 16
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- green
- hal.science
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion, other-oa)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Keywords
- P300 speller, brain-computer interface, EEG signal processing, event-related potentials
- MeSH terms
- Adult, Algorithms, Artificial Intelligence, Brain, Electroencephalography, Evoked Potentials, Humans, Male, Man-Machine Systems, Signal Processing, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.