xDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) is a communication system that allows to control a computer or any other device thanks to the brain activity. The BCI described in this paper is based on the P300 speller BCI paradigm introduced by Farwell and Donchin . An unsupervised algorithm is proposed to enhance P300 evoked potentials by estimating spatial filters; the raw EEG signals are then projected into the estimated signal subspace. Data recorded on three subjects were used to evaluate the proposed method. The results, which are presented using a Bayesian linear discriminant analysis classifier , show that the proposed method is efficient and accurate.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“They can enhance the P300 component and reduce the data dimensions, which is very suitable to our needs.”
From Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier (2020) · cites this paper as [23]
In the citing paper
“They can enhance the P300 component and reduce the data dimensions, which is very suitable to our needs.”
From Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier (2020) · cites this paper as [23]
In the citing paper
“as the xDAWN estimates the spatial filters by maximizing the difference between the averaged signals of the corresponding category and the whole EEG data[28].”
From A Cascade xDAWN EEGNet Structure for Unified Visual-Evoked Related Potential Detection (2024) · cites this paper as [28]
In the citing paper
“Unmixing of these global patterns using a number of spatial filters is therefore typically applied to the whole set of relevant electrodes as a basic step in many successful examples of EEG decoding [Ang et al., 2008; Blankertz et al., 2008; Rivet et al., 2009].”
From Deep learning with convolutional neural networks for EEG decoding and visualization (2017) · cites this paper as Rivet et al., 2009
In the citing paper
“For all ERP-based data analyses (P300, ERN, MRCP) the traditional approach is the approach which won the Kaggle BCI Competition (code and documentation at http://github.com/alexandrebarachant/bci-challenge-ner-2015), which uses a combination of xDAWN Spatial Filtering [83], Riemannian Geometry [84,85], channel subset selection and L 1 feature regularization”
From EEGNet: a compact convolutional neural network for EEG-based brain-computer interfaces (2018) · cites this paper as [84]
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“See [ 3 ] for a more detailed review of BCIs.”
BackgroundMethodIndependent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
RELATIONS BETWEEN TWO SETS OF VARIATES
HOTELLING, H. (1936) · Biometrika · doi:10.1093/biomet/28.3-4.321 · Cited by 5,263
Independent Component Analysis
Hyvärinen, A., Karhunen, J., & Oja, E. (2001) · Wiley eBooks · doi:10.1002/0471221317 · Cited by 5,007
MacKay, D. J. C. (1992) · Neural Computation · doi:10.1162/neco.1992.4.3.415 · Cited by 4,388 · cited 1×
“Among the proposed classifiers for BCIs, Bayesian linear discriminant analysis (BLDA) [2], [26] is chosen since it was proved to be efficient and was fully automatic (i.e., no hyper-parameters to adjust) [2].”
MethodAn introduction to kernel-based learning algorithms
Muller, K.-R., Mika, S., Ratsch, G., Tsuda, K., & Scholkopf, B. (2001) · IEEE Transactions on Neural Networks · doi:10.1109/72.914517 · Cited by 3,473
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 2×
“However, these repetitions decrease the number of symbols spelled per minute, e.g., with 15 repetitions, only two characters are typically spelled per minute [1], [8].”
BackgroundMethodBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024 · cited 1×
“The EEG was collected and stored using the BCI2000 system with the P300 speller scenario [24].”
MethodBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Self-citation
Research works printed but not linked: 2
- rivet, 2007, extraction de potentiels voqus p300 pour les interfaces cerveau-machine, Proc GRETSI, 625
- golub, 1996, Matrix Computation
Cited by
EEGNet: a compact convolutional neural network for EEG-based brain-computer interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aace8c · Cited by 5,115
“ach is the approach which won the Kaggle BCI Competition (code and documenta9 tion at http://github.com/alexandrebarachant/bci-challenge-ner-2015), which uses a combination of xDAWN Spatial Filtering [83], Riemannian Geometry [84,85], channel subset selection and L 1 feature regularization (referred to as xDAWN + RG f…”
MethodEEGNet: A Compact Convolutional Network for EEG-based Brain-Computer Interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2016) · arXiv · doi:10.48550/arxiv.1611.08024 · Cited by 5,105
“ach is the approach which won the Kaggle BCI Competition (code and documenta9 tion at http://github.com/alexandrebarachant/bci-challenge-ner-2015), which uses a combination of xDAWN Spatial Filtering [83], Riemannian Geometry [84,85], channel subset selection and L 1 feature regularization (referred to as xDAWN + RG f…”
MethodDeep learning with convolutional neural networks for EEG decoding and visualization
Schirrmeister, R. T., Springenberg, J. T., Fiederer, L. D. J., Glasstetter, M., Eggensperger, K., Tangermann, M., Hutter, F., Burgard, W., & Ball, T. (2017) · Human Brain Mapping · doi:10.1002/hbm.23730 · Cited by 3,751
“filters is therefore typically applied to the whole set of relevant electrodes as a basic step in many successful examples of EEG decoding [Ang et al., 2008; Blankertz et al., 2008; Rivet et al., 2009].”
A review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239
“Both types of features benefit from being extracted after spatial filtering [22, 136, 185, 188].”
BackgroundMethodBrain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“ensure that the number of repetitions remain unaffected [130,131].”
BackgroundTransfer Learning for Brain–Computer Interfaces: A Euclidean Space Data Alignment Approach
He, H., & Wu, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2913914 · Cited by 569
“3) xDAWN-SVM, which first performs xDAWN [27], [38] to spatially filter the EEG trials, and then PCA and SVM classification.”
MethodTransfer Learning for EEG-Based Brain–Computer Interfaces: A Review of Progress Made Since 2016
Wu, D., Xu, Y., & Lu, B.-L. (2022) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2020.3007453 · Cited by 434
“Popular spatial filters include common spatial patterns (CSP) [16], independent component analysis (ICA) [17], blind source separation [18], xDAWN [19], etc.”
Performance of the Emotiv Epoc headset for P300-based applications
Duvinage, M., Castermans, T., Petieau, M., Hoellinger, T., Cheron, G., & Dutoit, T. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-56 · Cited by 322
Brain-Computer Interface: Advancement and Challenges
Mridha, M. F., Das, S. C., Kabir, M. M., Lima, A. A., Islam, M. R., & Watanobe, Y. (2021) · Sensors · doi:10.3390/s21175746 · Cited by 263
“xDAWN [255] Enhance P300 evoked potentials Spatial Filtering P300 speller BCI paradigm There is room for improvization and enhancements.”
MethodA generic EEG artifact removal algorithm based on the multi-channel Wiener filter
Somers, B., Francart, T., & Bertrand, A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaac92 · Cited by 255
“4The original xDAWN algorithm in [27] was based on a QR decomposition and a singular value decomposition, although it was later shown to be an instance of a GEVD filter in [28].”
MethodEEG-Based BCI Control Schemes for Lower-Limb Assistive-Robots
Tariq, M., Trivailo, P. M., & Simic, M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00312 · Cited by 245
Hramov, A. E., Maksimenko, V. A., & Pisarchik, A. N. (2021) · Physics Reports · doi:10.1016/j.physrep.2021.03.002 · Cited by 213
Miao, Z., Zhao, M., Zhang, X., & Ming, D. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120209 · Cited by 186
Mak, J. N., Arbel, Y., Minett, J. W., McCane, L. M., Yuksel, B., Ryan, D., Thompson, D., Bianchi, L., & Erdogmus, D. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025003 · Cited by 195
“These includes methods based on orthogonal linear transformation (Dien et al 2003), blind source separation (Xu et al 2004, Li et al 2009a, Li et al 2009b), wavelet transform (Quian Quiroga and Garcia 2003, Bostanov and Kotchoubey 2006) and other advanced techniques (Rivet et al 2009).”
MethodLotte, F. (2014) · Guide to Brain-Computer Music Interfacing · doi:10.1007/978-1-4471-6584-2_7 · Cited by 178
“Therefore, maximizing J xDAWN actually maximizes the signal, i.e., it enhances the ERP response, and simultaneously minimizes the signal plus the noise, i.e., it makes the noise as small as possible (Rivet et al, 2009).”
BackgroundMethodInfluentialCorrecting robot mistakes in real time using EEG signals
Salazar-Gomez, A. F., DelPreto, J., Gil, S., Guenther, F. H., & Rus, D. (2017) · 2017 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2017.7989777 · Cited by 182
“order XDAWN filter [16], [17] (this order provided the best performance in offline analysis).”
BackgroundManifold Embedded Knowledge Transfer for Brain-Computer Interfaces
Zhang, W., & Wu, D. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2985996 · Cited by 183
“For the ERN dataset, we used xDAWN [35] to reduce the number of channels from 56 to 6.”
MethodObjective and Subjective Evaluation of Online Error Correction during P300-Based Spelling
Perrin, M., Maby, E., Daligault, S., Bertrand, O., & Mattout, J. (2012) · Advances in Human-Computer Interaction · doi:10.1155/2012/578295 · Cited by 203
“This high performance level might be partly attributable to the use of the xDAWN algorithm for spatial filtering [32] and to the departure from the row-column paradigm adapted from [23].”
MethodTransfer learning for motor imagery based brain–computer interfaces: A tutorial
Wu, D., Jiang, X., & Peng, R. (2022) · Neural Networks · doi:10.1016/j.neunet.2022.06.008 · Cited by 174
“, independent component analysis [12], xDAWN [13], canonical correlation analysis [14], common spatial patterns (CSP) [15], etc.”
MethodKim, S. K., Kirchner, E. A., Stefes, A., & Kirchner, F. (2017) · Scientific Reports · doi:10.1038/s41598-017-17682-7 · Cited by 165
“The xDAWN spatial filter 50 was used to enhance the signal-to-noise ratio.”
MethodA review of rapid serial visual presentation-based brain–computer interfaces
Lees, S., Dayan, N., Cecotti, H., McCullagh, P., Maguire, L., Lotte, F., & Coyle, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9817 · Cited by 149
Exploring Convolutional Neural Network Architectures for EEG Feature Extraction
Rakhmatulin, I., Dao, M.-S., Nassibi, A., & Mandic, D. P. (2024) · Sensors · doi:10.3390/s24030877 · Cited by 159
“Independent Component Analysis (ICA) is another popular technique used for EEG signal pre-processing [69].”
MethodJas, M., Larson, E., Engemann, D. A., Leppäkangas, J., Taulu, S., Hämäläinen, M., & Gramfort, A. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00530 · Cited by 152
“…novel methods or implement and disseminate the latest algorithms from the M/EEG community (Maris and Oostenveld, 2007; Kriegeskorte et al., 2008; Rivet et al., 2009; Gramfort et al., 2010, 2013b; Hauk et al., 2011; Khan and Cohen, 2013; Larson and Lee, 2013; Schurger et al., 2013; Haufe et al.,…”
MethodCross-Dataset Variability Problem in EEG Decoding With Deep Learning
Xu, L., Xu, M., Ke, Y., An, X., Liu, S., & Ming, D. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00103 · Cited by 173
“…Correlation Analysis (CCA) ( Lin et al., 2007) and Task-related Component Analysis (TRCA) (Nakanishi et al., 2018) are able to improve the speed of SSVEP-based BCI spellers. xDAWN (Rivet et al., 2009) and DCPM (Xu et al., 2018) algorithms are also perform well on P300-based BCI applications.”
MethodEfficient mental workload estimation using task-independent EEG features
Roy, R. N., Charbonnier, S., Campagne, A., & Bonnet, S. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026019 · Cited by 143
“…a binary ‘real’ workload estimation based on the ERPs of the test items of a Sternberg memory task was significantly enhanced when using an xDAWN (Rivet et al 2009) or a canonical correlation analysis (CCA; Hotelling 1936) filtering step with performances above 95% of correct binary…”
MethodPires, G., Nunes, U., & Castelo-Branco, M. S. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.11.016 · Cited by 150
Guy, V., Soriani, M., Bruno, M., Papadopoulo, T., Desnuelle, C., & Clerc, M. (2017) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2017.09.004 · Cited by 143
Choi, B., & Jo, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0074583 · Cited by 141
“This work implemented a simple P300-based BCI protocol using the xDAWN spatial filter which was proposed to enhance evoked potentials [37].”
MethodCohen, M. X. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118809 · Cited by 124
Spatial Filtering for EEG-Based Regression Problems in Brain–Computer Interface (BCI)
Wu, D., King, J.-T., Chuang, C.-H., Lin, C.-T., & Jung, T.-P. (2018) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2017.2688423 · Cited by 116
A P300-based Quantitative Comparison between the Emotiv Epoc Headset and a Medical EEG Device
Duvinage, M., Castermans, T., Dutoit, T., Petieau, M., Hoellinger, T., Saedeleer, C. D., Seetharaman, K., & Cheron, G. A. (2012) · IASTED International Conference on Biomedical Engineering (BioMed) · doi:10.2316/p.2012.764-071 · Cited by 134
“Afterwards, a spatial filter is designed thanks to an xDAWN algorithm [16].”
MethodDiscriminative Canonical Pattern Matching for Single-Trial Classification of ERP Components
Xiao, X., Xu, M., Jin, J., Wang, Y., Jung, T.-P., & Ming, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2958641 · Cited by 113
“In particular, it got the third place for dataset 1, 2 and 3 but had a poor performance in dataset 4 and 5. xDAWN will perform better with more training samples [19].”
BackgroundMethodInfluentialElectroencephalography ( EEG )‐Based Brain–Computer Interfaces
Lotte, F., Bougrain, L., & Clerc, M. (2015) · Wiley eBooks · doi:10.1002/047134608x.w8278 · Cited by 142
“One of them is the xDAWN spatial filter [80].”
BackgroundOn the Vulnerability of CNN Classifiers in EEG-Based BCIs
Zhang, X., & Wu, D. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2908955 · Cited by 126
“xDAWN+RG used xDAWN spatial filtering [30], Riemannian geometry [3] and ElasticNet to classify the epochs.”
MethodA robust sensor-selection method for P300 brain–computer interfaces
Cecotti, H., Rivet, B., Congedo, M., Jutten, C., Bertrand, O., Maby, E., & Mattout, J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016001 · Cited by 117
“The considered method for creating spatial filters is based on the xDAWN algorithm [36, 37].”
MethodSelf-citationCecotti, H., Eckstein, M. P., & Giesbrecht, B. (2014) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2014.2302898 · Cited by 109
Decoding subjective emotional arousal from EEG during an immersive virtual reality experience
Hofmann, S., Klotzsche, F., Mariola, A., Nikulin, V. V., Villringer, A., & Gaebler, M. (2021) · eLife · doi:10.7554/elife.64812 · Cited by 110
Noninvasive Brain–Computer Interfaces for Augmentative and Alternative Communication
Akçakaya, M., Peters, B., Moghadamfalahi, M., Mooney, A. R., Orhan, U., Oken, B., Deniz Erdogmus, B., & Fried-Oken, M. B. (2014) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2013.2295097 · Cited by 115
“[127] B.”
BackgroundMethodInfluentialA Plug&Play P300 BCI Using Information Geometry
Barachant, A., & Congedo, M. (2014) · arXiv · doi:10.48550/arxiv.1409.0107 · Cited by 102
“The first is named XDAWN and is composed by a spatial filtering using the xDAWN method [25] and a regularized LDA [26] for classification.”
MethodAdapting the P300-Based Brain–Computer Interface for Gaming: A Review
Kaplan, A., Shishkin, S. L., Ganin, I. P., Basyul, I. A., & Zhigalov, A. (2013) · IEEE Transactions on Computational Intelligence and AI in Games · doi:10.1109/tciaig.2012.2237517 · Cited by 115
“xDAWN algorithm [37] is used for the classifier training.”
MethodAn Efficient ERP-Based Brain-Computer Interface Using Random Set Presentation and Face Familiarity
Yeom, S.-K., Fazli, S., Müller, K., & Lee, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111157 · Cited by 112
Review of brain encoding and decoding mechanisms for EEG-based brain–computer interface
Xu, L., Xu, M., Jung, T., & Ming, D. (2021) · Cognitive Neurodynamics · doi:10.1007/s11571-021-09676-z · Cited by 110
“Rivet et al. (2009) designed an unsupervised algorithm named xDAWN to enhance the SNR of evoked potentials.”
MethodA novel P300 BCI speller based on the Triple RSVP paradigm
Lin, Z., Zhang, C., Zeng, Y., Tong, L., & Yan, B. (2018) · Scientific Reports · doi:10.1038/s41598-018-21717-y · Cited by 103
Mak, J. N., McFarland, D. J., Vaughan, T. M., McCane, L. M., Tsui, P. Z., Zeitlin, D., Sellers, E. W., & Wolpaw, J. R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026014 · Cited by 109
“…optimizing the visual presentation paradigm (Salvaris and Sepulveda 2009, Sellers et al 2006, Townsend et al 2010), the feature extraction method (Rivet et al 2009, Serby et al 2005, Xu et al 2004), and/or the classification algorithm (Krusienski et al 2006, Lenhardt et al 2008, Rakotomamonjy…”
BackgroundMethodDOSED: A deep learning approach to detect multiple sleep micro-events in EEG signal
Chambon, S., Thorey, V., Arnal, P. J., Mignot, E. J.-M., & Gramfort, A. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.03.017 · Cited by 102
Universal Joint Feature Extraction for P300 EEG Classification Using Multi-Task Autoencoder
Ditthapron, A., Banluesombatkul, N., Ketrat, S., Chuangsuwanich, E., & Wilaiprasitporn, T. (2019) · IEEE Access · doi:10.1109/access.2019.2919143 · Cited by 93
“To further validate our model using a state-of-the-art P300 feature extraction method, we compared our ERPENet against the Xdawn algorithm [43].”
MethodSparse Bayesian Learning for End-to-End EEG Decoding
Wang, W., Qi, F., Wipf, D., Cai, C., Yu, T., Li, Y., Zhang, Y., Yu, Z., & Wu, W. (2023) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2023.3299568 · Cited by 99
“…combination (MCC) [6], minimum energy combination (MEC) [6] were employed to improvethesignal-to-noiseratio(SNR)ofthesteady-statevisual evokedpotentials(SSVEPs)inSSVEP-basedBCIs;Similarly, the xDAWN algorithm attempted to enhance the SNR of the event-related potentials (ERPs) in ERP-based BCIs [7].”
MethodHuman-agent co-adaptation using error-related potentials
Ehrlich, S. K., & Cheng, G. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae069 · Cited by 91
“Salazar-Gomez et al (2017) obtained online decoding accuracies around 65% across four subjects using correlation-based features and covariance features based on spatially filtered EEG signals using xDAWN (Rivet et al 2009).”
BackgroundSpüler, M., Walter, A., Rosenstiel, W., & Bogdan, M. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2290870 · Cited by 86
“While for P300 BCIs different methods for spatial filtering have been suggested [6], [7], [8], [9], they are rarely used and a comparison of those methods with standard spatial filtering methods like Laplace or common average referencing (CAR)”
MethodWang, Z., Chen, C., Li, J., Wan, F., Sun, Y., & Wang, H. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3237319 · Cited by 75
“In order to improve the accuracy of detecting ERP signals, Rivet et al. [17] raised xDAWN, a spatial filtering method, to enhance P300 potentials with respect to the Non-P300 potentials; further, Barachant improved the xDAWN to a generalization to any type of ERP [18].”
MethodRotational data augmentation for electroencephalographic data
Krell, M. M., & Kim, S. K. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036864 · Cited by 75
“Afterwards, the xDAWN spatial filter [3] was trained on the complete training data and then applied with 8 resulting channels.”
MethodZhang, X., Wu, D., Ding, L., Luo, H., Lin, C.-T., Jung, T., & Chavarriaga, R. (2020) · National Science Review · doi:10.1093/nsr/nwaa233 · Cited by 84
“First, 16 xDAWN spatial filters [46], eight for the target trials and another eight for the non-target (1)https://www.”
BackgroundMOCNN: A Multiscale Deep Convolutional Neural Network for ERP-Based Brain-Computer Interfaces
Jin, J., Xu, R., Daly, I. P., Zhao, X., Wang, X., & Cichocki, A. S. (2024) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2024.3390805 · Cited by 69
Channel selection methods for the P300 Speller
Colwell, K. A., Ryan, D. B., Morton, K. D., Sellers, E. W., & Collins, L. M. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.04.009 · Cited by 72
Li, F., Xia, Y., Wang, F., Zhang, D., Li, X., & He, F. (2020) · Applied Sciences · doi:10.3390/app10051804 · Cited by 64
“XDAWN spatial filters, specially design for Event Related Potentials (ERP), were proposed by Bertrand Rivet [23].”
BackgroundMethodInfluentialMarathe, A. R., Lawhern, V. J., Wu, D., Slayback, D., & Lance, B. J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2502323 · Cited by 64
“[47] and Cecotti et al.”
Review of Riemannian Distances and Divergences, Applied to SSVEP-based BCI
Chevallier, S., Kalunga, E. K., Barthélemy, Q., & Monacelli, É. (2020) · Neuroinformatics · doi:10.1007/s12021-020-09473-9 · Cited by 65
“Consequently, spatial filtering methods are developed to enhance SNR, such as common spatial patterns (CSP) (Jo-hannes et al. 1999), independent component analysis (ICA) (Wang and James 2006), xDAWN (Rivet et al. 2009) or canonical correlation analysis (CCA) (Yang et al. 2017).”
MethodCorralejo, R., Nicolas-Alonso, L. F., Álvarez, D., & Hornero, R. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1191-5 · Cited by 69
“Previous studies focused on improving P300-based BCIs performance assessing feature extraction and classification methods [2, 17, 19, 31, 32, 39, 43] or different visual stimuli presentation paradigms [15, 16, 33, 38].”
MethodAn Adaptive Spatial Filter for User-Independent Single Trial Detection of Event-Related Potentials
Wöhrle, H., Krell, M. M., Straube, S., Kim, S. K., Kirchner, E. A., & Kirchner, F. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2402252 · Cited by 67
“…the optimal filters W can be found by maximizing the signal-to-signal-plus-noise-ratio (SSNR) as given by the generalized Rayleigh quotient In the standard xDAWN algorithm [7], this optimization problem is solved by combining a QR matrix decomposition (QRD) with a singular value decomposition (SVD).”
BackgroundMethodInfluentialMayaud, L., Congedo, M., Laghenhove, A. V., Orlikowski, D., Figère, M., Azabou, É., & Cheliout-Heraut, F. (2013) · Neurophysiologie Clinique · doi:10.1016/j.neucli.2013.06.002 · Cited by 72
“The xDAWN algorithm [30] is a spatial filter that optimizes spatial weights to enhance the”
MethodCongedo, M., Goyat, M., Tarrin, N., Ionescu, G., Varnet, L., Rivet, B., Phlypo, R., Jrad, N., Acquadro, M., & Jutten, C. (2011) · HAL · Cited by 62
Self-citationA Review of EEG-Based Brain-Computer Interface Systems Design
Zhang, W., Tan, C., Sun, F., Wu, H., & Zhang, B. (2018) · Brain Science Advances · doi:10.26599/bsa.2018.9050010 · Cited by 70
“[45] proposed an xDawn algorithm to define a P300 subspace and designed a spatial filter for P300 detection.”
MethodToward functioning and usable brain–computer interfaces (BCIs): A literature review
Pasqualotto, E., Federici, S., & Belardinelli, M. O. (2011) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2011.589486 · Cited by 74
Banville, H. J., & Falk, T. H. (2016) · Brain-Computer Interfaces · doi:10.1080/2326263x.2015.1134958 · Cited by 66
Multimodal Movement Prediction - Towards an Individual Assistance of Patients
Kirchner, E. A., Tabie, M., & Seeland, A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0085060 · Cited by 58
“In the algorithm [30], this true ERP matrix is estimated using a least squares approach.”
MethodZhang, X. L., Wu, D., Ding, L., Luo, H., Lin, C.-T., Jung, T., & Chavarriaga, R. (2020) · Zürcher Hochschule für Angewandte Wissenschaften digital collection (Zurich University of Applied Sciences) · doi:10.21256/zhaw-20507 · Cited by 57
A systematic deep learning model selection for p300-based brain-computer interfaces
Abibullaev, B., & Zollanvari, A. (2022) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2021.3051136 · Cited by 53
“1) Segmentation: Continuous EEG data were segmented into the target and nontarget trials with 600 ms duration after the stimulus event onset markers [14], [15], [67].”
MethodShan, H., Liu, Y., & Stefanov, T. (2018) · Proceedings of the Twenty-Seventh International Joint Conference on Artificial Intelligence · doi:10.24963/ijcai.2018/222 · Cited by 53
A Hybrid FPGA-Based System for EEG- and EMG-Based Online Movement Prediction
Wöhrle, H., Tabie, M., Kim, S. K., Kirchner, F., & Kirchner, E. A. (2017) · Sensors · doi:10.3390/s17071552 · Cited by 53
“This makes it possible to generate nodes that implement algorithms frequently used in BCIs, such as spatial filters [139,140] or classifiers.”
Language Model Applications to Spelling with Brain-Computer Interfaces
Mora-Cortes, A., Manyakov, N. V., Chumerin, N., & Hulle, M. M. V. (2014) · Sensors · doi:10.3390/s140405967 · Cited by 59
“This research was primary performed in the preprocessing component (see Figure 2), searching for a better spatial and frequency filtering or a better feature selection and construction methods [59–62], on the classifier component [63], and in the design of the external-stimulation device , e.g .”
MethodSignal Generation, Acquisition, and Processing in Brain Machine Interfaces: A Unified Review
Salahuddin, U., & Gao, P. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.728178 · Cited by 59
Accelerating Reinforcement Learning using EEG-based implicit human feedback
Xu, D., Agarwal, M., Gupta, E., Fekri, F., & Sivakumar, R. (2021) · Neurocomputing · doi:10.1016/j.neucom.2021.06.064 · Cited by 51
“In spatial filtering, we compute prototype responses of each class, i.e., “correct” and “erroneous”, by averaging all training trials in the corresponding classes(“xDAWN Spatial Filter” [53], [20]).”
MethodCecotti, H., & Ries, A. J. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.07.500 · Cited by 50
Tanaka, H. (2020) · Scientific Reports · doi:10.1038/s41598-019-56962-2 · Cited by 54
The LDA beamformer: Optimal estimation of ERP source time series using linear discriminant analysis
Treder, M. S., Porbadnigk, A. K., Avarvand, F. S., Müller, K., & Blankertz, B. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.01.019 · Cited by 50
“Similarly, the xDAWN method is used as a preprocessing tool for enhancing ERP responses prior to classification in brain–computer interfaces (Rivet et al., 2009).”
Universal adversarial perturbations for CNN classifiers in EEG-based BCIs
Liu, Z., Meng, L., Zhang, X. L., Fang, W., & Wu, D. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0f4c · Cited by 54
“We used the TLM-UAP generated from CNN models to attack some traditional non-CNN models, i.e. xDAWN [40] spatial filtering and logistic regression (LR) for P300 and ERN, and common spatial pattern [41] filtering and LR classifier for MI. TLM-UAPs with three different amplitudes were generated by…”
InfluentialSingle-Trial ERP Component Analysis Using a Spatiotemporal LCMV Beamformer
van Vliet, M., Chumerin, N., Deyne, S. D., Wiersema, J. R., Fias, W., Storms, G., & Hulle, M. M. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2468588 · Cited by 46
“a spatial filter, using the xDAWN algorithm [41], keeping the four most descriptive spatial components, and then using an lSVM to perform the final filtering.”
MethodBrain–Computer Interface Contributions to Neuroergonomics
Lotte, F., & Roy, R. N. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-811926-6.00007-5 · Cited by 47
“For online applications, we can notably cite the Common Spatial Patterns (CSP) algorithm to estimate mental states based on oscillatory activity (Blankertz et al., 2008), or xDAWN to estimate states based on Event Related Potentials (Rivet et al., 2009; Roy et al., 2015).”
MethodMarathe, A. R., Ries, A. J., Lawhern, V. J., Lance, B. J., Touryan, J., McDowell, K., & Cecotti, H. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00270 · Cited by 47
“Spatial filters are obtained through the Rayleigh quotient by maximizing the SSNR (Rivet et al., 2009).”
MethodInfluentialImproving BCI performance through co-adaptation: Applications to the P300-speller
Mattout, J., Perrin, M., Bertrand, O., & Maby, E. (2015) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2014.10.006 · Cited by 51
“…automated correction, so as to learn those responses for this particular individual; the initial training phase enables to optimize spatial filters [12] and a probabilistic classifier [13] that can then be used to detect error signals from each feedback related response; once an error has been…”
BackgroundBCI Could Make Old Two-Player Games Even More Fun: A Proof of Concept with “Connect Four”
Maby, E., Perrin, M., Bertrand, O., Sanchez, G., & Mattout, J. (2012) · Advances in Human-Computer Interaction · doi:10.1155/2012/124728 · Cited by 48
“To extract the most relevant signal components and to increase the signal-to-noise ratio (SNR), we used the xDAWN algorithm which has been specifically developed for the P300 Speller [30].”
MethodInfluentialpySPACE—a signal processing and classification environment in Python
Krell, M. M., Straube, S., Seeland, A., Wöhrle, H., Teiwes, J., Metzen, J. H., Kirchner, E. A., & Kirchner, F. (2013) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2013.00040 · Cited by 45
“…are equally split into training and testing data to train the supervised learning algorithms, which are, in this example, the spatial filter xDAWN (Rivet et al., 2009), the feature normalization and the classifier later on [here, the LibSVM Support Vector Machine as implemented by Chang and Lin…”
BackgroundMethodMulti-source manifold feature transfer learning with domain selection for brain-computer interfaces
She, Q., Cai, Y., Du, S., & Chen, Y. (2022) · Neurocomputing · doi:10.1016/j.neucom.2022.09.124 · Cited by 44
Rivet, B., & Souloumiac, A. (2012) · Signal Processing · doi:10.1016/j.sigpro.2012.07.019 · Cited by 44
“ERPs are involved), xDAWN algorithm, which thus sums up to classical beamforming, and CCA provide the same estimate as shown in [18].”
BackgroundMethodResultSelf-citationPhilip, J. T., & George, S. T. (2019) · Clinical EEG and Neuroscience · doi:10.1177/1550059419842753 · Cited by 47
“1-10 Hz), Windsorizing (10-90), Epoch (0-1000 ms) Epoch averaging Euclidian distance Mean CA (3 channels, 100 characters): 64.”
Backgroundsw-SVM: sensor weighting support vector machines for EEG-based brain–computer interfaces
Jrad, N., Congedo, M., Phlypo, R., Rousseau, S., Flamary, R., Yger, F., & Rakotomamonjy, A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056004 · Cited by 45
“Therefore, it provides an adequate base to ascertain the robustness of the proposed algorithm as compared to a spatial filter maximizing a ratio of class variances followed by an SVM classifier [16], a spatial filter maximizing an SNR criterion followed by an SVM classifier [10] and a classical SVM approach [17].”
MethodInfluentialRegularization and a general linear model for event-related potential estimation
Kristensen, E., Guérin-Dugué, A., & Rivet, B. (2017) · Behavior Research Methods · doi:10.3758/s13428-017-0856-z · Cited by 42
Self-citationHandling Few Training Data: Classifier Transfer Between Different Types of Error-Related Potentials
Kim, S. K., & Kirchner, E. A. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2507868 · Cited by 41
“Data flow [46]: The continuous EEGs were segmented, normalized, decimated, band-pass filtered, and the signal to noise ratio was enhanced by applying a spatial filter called xDAWN [47].”
MethodEEG-Based Brain–Computer Interfaces are Vulnerable to Backdoor Attacks
Meng, L., Jiang, X., Huang, J., Zeng, Z., Yu, S. P., Jung, T., Lin, C., Chavarriaga, R., & Wu, D. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3273214 · Cited by 46
“, xDAWN [27] spatial filtering and Logistic Regression (LR) classifier for the ERN and P300 datasets, and common spatial pattern (CSP) [28] filtering and LR classifier for the MI dataset.”
MethodFunctional Brain Connectivity as a New Feature for P300 Speller
Kabbara, A., Khalil, M. A., Falou, W. E., Eid, H., & Hassan, M. (2016) · PLoS ONE · doi:10.1371/journal.pone.0146282 · Cited by 49
“We used different methods existing in the state-of-the art of “P300 speller” to compare them with the proposed method: 1) xDAWN algorithm [15]: xDAWN is a spatial filtering algorithm based on SVD and PCA.”
MethodChannel Selection Based on Phase Measurement in P300-Based Brain-Computer Interface
Xu, M., Qi, H., Ma, L., Sun, C., Zhang, L., Wan, B., Yin, T., & Ming, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0060608 · Cited by 40
“Meanwhile, a pre-processing using a spatial filter (SF) based on the xDAWN algorithm [26],[27] helps to select the optimal channels remarkably [10].”
Chaurasiya, R. K., Londhe, N. D., & Ghosh, S. (2016) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2016.1203047 · Cited by 40
Zeyl, T. J., Yin, E., Keightley, M., & Chau, T. T. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2461495 · Cited by 43
“Many improvements have been made to P300 spellers in recent years, with research focusing on signal processing [14], stimuli design [15], [16], channel selection [17], dynamic stopping [18], and natural language processing [19].”
BackgroundFaster P300 Classifier Training Using Spatiotemporal Beamforming
Wittevrongel, B., & Hulle, M. M. V. (2016) · International Journal of Neural Systems · doi:10.1142/s0129065716500143 · Cited by 42
A Practical EEG-Based Human-Machine Interface to Online Control an Upper-Limb Assist Robot
Song, Y., Cai, S., Yang, L., Li, G., Wu, W., & Xie, L. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00032 · Cited by 39
“After the above steps, the spatial filter based on xDAWN algorithm (Rivet et al., 2009) was used to enhance the evoked potential of the data which means to improve the signal to signal-plus-noise ratio (SSNR).”
MethodOptimizing the Performances of a P300-Based Brain–Computer Interface in Ambulatory Conditions
Castermans, T., Duvinage, M., Petieau, M., Hoellinger, T., Saedeleer, C. D., Seetharaman, K., Bengoetxea, A., Cheron, G. A., & Dutoit, T. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2179421 · Cited by 43
Yasemin, M., Cruz, A., Nunes, U., & Pires, G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/acabe9 · Cited by 40
“It should be stressed that continuous tasks have implications in terms of classification pipeline as there are no correct ERPs as in discrete feedback tasks, and may require asynchronous detection [13].”
MethodInfluentialSpatio-temporal common pattern: A companion method for ERP analysis in the time domain
Congedo, M., Korczowski, L., Arnaud Delorme, A., & Lopes, F. H. D. S. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.04.008 · Cited by 40
“Such a CSP specifically conceived for the analysis of ERPs has been proposed by Rivet et al. (2009), who also formalized an appropriate ensemble average estimation for overlapping ERPs introducing the use of a multivariate regression model.”
DelPreto, J., Salazar-Gómez, A. F., Gil, S., Hasani, R., Guenther, F. H., & Rus, D. L. (2020) · Autonomous Robots · doi:10.1007/s10514-020-09916-x · Cited by 40
Efficient Workload Classification based on Ignored Auditory Probes: A Proof of Concept
Roy, R. N., Bonnet, S., Charbonnier, S., & Campagne, A. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2016.00519 · Cited by 39
“The matrix D i is a Toeplitz binary matrix that indicates the stimulation onset for the i th class (Rivet et al., 2009).”
Background
Metadata
- Authors
- Rivet, B., Souloumiac, A., Attina, V., & Gibert, G.
- Affiliations
- Institut polytechnique de Grenoble (FR)
- Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR)
- Lyon 1 Université (FR)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2009-08
- Volume
- 56
- Issue
- 8
- Pages
- 2035-2043
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2104063964
- Cited by
- 537
- References
- 29
- Citations by year
- 2026: 21 · 2025: 37 · 2024: 50 · 2023: 43 · 2022: 31 · 2021: 37 · 2020: 44 · 2019: 35 · 2018: 38 · 2017: 32 · 2016: 36 · 2015: 33 · 2014: 23 · 2013: 34 · 2012: 16
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- green
- hal.science
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion, other-oa)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Keywords
- P300 speller, brain-computer interface, EEG signal processing, event-related potentials
- MeSH terms
- Adult, Algorithms, Artificial Intelligence, Brain, Electroencephalography, Evoked Potentials, Humans, Male, Man-Machine Systems, Signal Processing, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.