Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 297

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Shape-Based Computer-Aided Detection of Lung Nodules in Thoracic CT Images

Open access
Xujiong Ye, Xinyu Lin, Dehmeshki, J., Slabaugh, G., Beddoe, G.·2009·IEEE Transactions on Biomedical Engineering

Abstract

In this paper, a new computer tomography (CT) lung nodule computer-aided detection (CAD) method is proposed for detecting both solid nodules and ground-glass opacity (GGO) nodules (part solid and nonsolid). This method consists of several steps. First, the lung region is segmented from the CT data using a fuzzy thresholding method. Then, the volumetric shape index map, which is based on local Gaussian and mean curvatures, and the "dot" map, which is based on the eigenvalues of a Hessian matrix, are calculated for each voxel within the lungs to enhance objects of a specific shape with high spherical elements (such as nodule objects). The combination of the shape index (local shape information) and "dot" features (local intensity dispersion information) provides a good structure descriptor for the initial nodule candidates generation. Antigeometric diffusion, which diffuses across the image edges, is used as a preprocessing step. The smoothness of image edges enables the accurate calculation of voxel-based geometric features. Adaptive thresholding and modified expectation-maximization methods are employed to segment potential nodule objects. Rule-based filtering is first used to remove easily dismissible nonnodule objects. This is followed by a weighted support vector machine (SVM) classification to further reduce the number of false positive (FP) objects. The proposed method has been trained and validated on a clinical dataset of 108 thoracic CT scans using a wide range of tube dose levels that contain 220 nodules (185 solid nodules and 35 GGO nodules) determined by a ground truth reading process. The data were randomly split into training and testing datasets. The experimental results using the independent dataset indicate an average detection rate of 90.2%, with approximately 8.2 FP/scan. Some challenging nodules such as nonspherical nodules and low-contrast part-solid and nonsolid nodules were identified, while most tissues such as blood vessels were excluded. The method's high detection rate, fast computation, and applicability to different imaging conditions and nodule types shows much promise for clinical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2009.2017027

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

Metadata

Authors
Ye, X., Lin, X., Dehmeshki, J., Slabaugh, G., & Beddoe, G.
Venue
IEEE Transactions on Biomedical Engineering
Published
2009-07
Volume
56
Issue
7
Pages
1810-1820
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2167803594
Cited by
297
References
24
FWCI
13.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.