The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Shape-Based Computer-Aided Detection of Lung Nodules in Thoracic CT Images
Open accessAbstract
In this paper, a new computer tomography (CT) lung nodule computer-aided detection (CAD) method is proposed for detecting both solid nodules and ground-glass opacity (GGO) nodules (part solid and nonsolid). This method consists of several steps. First, the lung region is segmented from the CT data using a fuzzy thresholding method. Then, the volumetric shape index map, which is based on local Gaussian and mean curvatures, and the "dot" map, which is based on the eigenvalues of a Hessian matrix, are calculated for each voxel within the lungs to enhance objects of a specific shape with high spherical elements (such as nodule objects). The combination of the shape index (local shape information) and "dot" features (local intensity dispersion information) provides a good structure descriptor for the initial nodule candidates generation. Antigeometric diffusion, which diffuses across the image edges, is used as a preprocessing step. The smoothness of image edges enables the accurate calculation of voxel-based geometric features. Adaptive thresholding and modified expectation-maximization methods are employed to segment potential nodule objects. Rule-based filtering is first used to remove easily dismissible nonnodule objects. This is followed by a weighted support vector machine (SVM) classification to further reduce the number of false positive (FP) objects. The proposed method has been trained and validated on a clinical dataset of 108 thoracic CT scans using a wide range of tube dose levels that contain 220 nodules (185 solid nodules and 35 GGO nodules) determined by a ground truth reading process. The data were randomly split into training and testing datasets. The experimental results using the independent dataset indicate an average detection rate of 90.2%, with approximately 8.2 FP/scan. Some challenging nodules such as nonspherical nodules and low-contrast part-solid and nonsolid nodules were identified, while most tissues such as blood vessels were excluded. The method's high detection rate, fast computation, and applicability to different imaging conditions and nodule types shows much promise for clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,119
Digital Image Processing: PIKS Inside
Pratt, W. K. (2002) · Wiley eBooks · doi:10.1002/0471221325 · Cited by 4,340
Fuzzy Model Identification Based on Cluster Estimation
Chiu, S. L. (1994) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/ifs-1994-2306 · Cited by 2,782
Digital image processing (2nd ed.)
(1992) · CVGIP: Image Understanding · doi:10.1016/1049-9660(92)90019-y · Cited by 1,780
Markov Random Field Modeling in Computer Vision
Li, S. Z. (1995) · Computer Science Workbench · doi:10.1007/978-4-431-66933-3 · Cited by 1,276
Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images
Hu, S., Hoffman, E. A., & Reinhardt, J. M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.929615 · Cited by 940
Support Vector Machines: Training and Applications
Osuna, E., Freund, R. M., & Girosi, F. (1997) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 697
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Lee, Y., Hara, T., Fujita, H., Itoh, S., & Ishigaki, T. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932744 · Cited by 457
Li, Q., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1581411 · Cited by 349
Three-dimensional computer-aided diagnosis scheme for detection of colonic polyps
Yoshida, H., & Nappi, J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974921 · Cited by 343
Tissue classification based on 3D local intensity structures for volume rendering
Sato, Y., Westin, C., Bhalerao, A., Nakajima, S., Shiraga, N., Tamura, S., & Kikinis, R. (2000) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.856997 · Cited by 338
Gurcan, M. N., Sahiner, B., Petrick, N., Chan, H., Kazerooni, E. A., Cascade, P. N., & Hadjiiski, L. (2002) · Medical Physics · doi:10.1118/1.1515762 · Cited by 309
Awai, K., Murao, K., Ozawa, A., Komi, M., Hayakawa, H., Hori, S., & Nishimura, Y. (2004) · Radiology · doi:10.1148/radiol.2302030049 · Cited by 272
Suzuki, K., Armato, S. G., Li, F., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1580485 · Cited by 262
Automated detection of lung nodules in CT scans: Preliminary results
Armato, S. G., Giger, M. L., & MacMahon, H. (2001) · Medical Physics · doi:10.1118/1.1387272 · Cited by 250
Paik, D. S., Beaulieu, C. F., Rubin, G. D., Acar, B., Jeffrey, R. B., Yee, J., Dey, J., & Napel, S. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.826362 · Cited by 248
Using Partial Derivatives of 3D Images to Extract Typical Surface Features
Monga, O., & Benayoun, S. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1014 · Cited by 189
Patient-specific models for lung nodule detection and surveillance in CT images
Brown, M. S., McNitt-Gray, M. F., Goldin, J. G., Suh, R. D., Sayre, J. W., & Aberle, D. R. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974919 · Cited by 169
Computer-aided Diagnosis of Localized Ground-Glass Opacity in the Lung at CT: Initial Experience
Kim, K. G., Goo, J. M., Kim, J. H., Lee, H. J., Min, B. G., Bae, K. T., & Im, J.-G. (2005) · Radiology · doi:10.1148/radiol.2372041461 · Cited by 88
Ge, Z., Sahiner, B., Chan, H., Hadjiiski, L. M., Cascade, P. N., Bogot, N., Kazerooni, E. A., Wei, J., & Zhou, C. (2005) · Medical Physics · doi:10.1118/1.1944667 · Cited by 87
Farag, A. A., El-Baz, A. S., Gimel’farb, G., Falk, R. L., & Hushek, S. G. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30136-3_104 · Cited by 47
A Multiclassifier Approach for Lung Nodule Classification
Pereira, C., Alexandre, L. A., Mendonça, A. M., & Campilho, A. (2006) · Lecture notes in computer science · doi:10.1007/11867661_55 · Cited by 11
Cited by
Ardila, D., Kiraly, A. P., Bharadwaj, S., Choi, B., Reicher, J. J., Peng, L., Tse, D., Etemadi, M., Ye, W., Corrado, G., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0447-x · Cited by 2,167
Computer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
El-Baz, A., Beache, G. M., Gimel'farb, G., Suzuki, K., Okada, K., Elnakib, A., Soliman, A., & Abdollahi, B. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/942353 · Cited by 277
Automatic detection of subsolid pulmonary nodules in thoracic computed tomography images
Jacobs, C., van Rikxoort, E. M., Twellmann, T., Scholten, E. T., de Jong, P. A., Kuhnigk, J.-M., Oudkerk, M., de Koning, H. J., Prokop, M., Schaefer-Prokop, C., et al. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.12.001 · Cited by 262
Metadata
- Authors
- Ye, X., Lin, X., Dehmeshki, J., Slabaugh, G., & Beddoe, G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2009-07
- Volume
- 56
- Issue
- 7
- Pages
- 1810-1820
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2167803594
- Cited by
- 297
- References
- 24
- FWCI
- 13.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.