The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Unobtrusive and Ubiquitous In-Home Monitoring: A Methodology for Continuous Assessment of Gait Velocity in Elders
Open accessAbstract
Gait velocity has been shown to quantitatively estimate risk of future hospitalization, a predictor of disability, and has been shown to slow prior to cognitive decline. In this paper, we describe a system for continuous and unobtrusive in-home assessment of gait velocity, a critical metric of function. This system is based on estimating walking speed from noisy time and location data collected by a "sensor line" of restricted view passive infrared motion detectors. We demonstrate the validity of our system by comparing with measurements from the commercially available GAITRite walkway system gait mat. We present the data from 882 walks from 27 subjects walking at three different subject-paced speeds (encouraged to walk slowly, normal speed, or fast) in two directions through a sensor line. The experimental results show that the uncalibrated system accuracy (average error) of estimated velocity was 7.1 cm/s (SD = 11.3 cm/s), which improved to 1.1 cm/s (SD = 9.1 cm/s) after a simple calibration procedure. Based on the average measured walking speed of 102 cm/s, our system had an average error of less than 7% without calibration and 1.1% with calibration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical performance measures in the clinical setting
Studenski, S., Perera, S., Wallace, D., Chandler, J. M., Duncan, P. W., Rooney, E., Fox, M., & Guralnik, J. M. (2003) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2003.51104.x · Cited by 1,218
Mihailidis, A., Carmichael, B., & Boger, J. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.834386 · Cited by 208
Unobtrusive assessment of activity patterns associated with mild cognitive impairment
Hayes, T. L., Abendroth, F., Adami, A., Pavel, M., Zitzelberger, T. A., & Kaye, J. A. (2008) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2008.07.004 · Cited by 187 · cited 4×
“However, these have been shown to be minor, with a less than 2% overall data loss [4].”
BackgroundMethodInfluentialSelf-citation
Cited by
Bonato, P. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936554 · Cited by 423
“It is worth noting that the combination of home robots and wearable technology is somewhat complementary to installing sensing components in living environments [61].”
BackgroundMorris, R., Lord, S., Bunce, J., Burn, D., & Rochester, L. (2016) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2016.02.012 · Cited by 307
Kaye, J. A., Maxwell, S. A., Mattek, N., Hayes, T. L., Dodge, H., Pavel, M., Jimison, H. B., Wild, K., Boise, L., & Zitzelberger, T. A. (2011) · The Journals of Gerontology Series B: Psychological Sciences and Social Sciences · doi:10.1093/geronb/gbq095 · Cited by 294
Self-citationBody Area Networks for Ubiquitous Healthcare Applications: Opportunities and Challenges
Jovanov, E., & Milenkovic, A. (2011) · Journal of Medical Systems · doi:10.1007/s10916-011-9661-x · Cited by 183
Ambient Sensors for Elderly Care and Independent Living: A Survey
Uddin, M. Z., Khaksar, W., & Torresen, J. (2018) · Sensors · doi:10.3390/s18072027 · Cited by 166
Unobtrusive measurement of daily computer use to detect mild cognitive impairment
Kaye, J., Mattek, N., Dodge, H. H., Campbell, I., Hayes, T., Austin, D., Hatt, W., Wild, K., Jimison, H., & Pavel, M. (2014) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2013.01.011 · Cited by 145
Self-citationBoise, L., Wild, K., Mattek, N., Ruhl, M., Dodge, H. H., & Kaye, J. (2013) · Gerontechnology · doi:10.4017/gt.2013.11.3.001.00 · Cited by 139
Self-citationAutonomous unobtrusive detection of mild cognitive impairment in older adults
Akl, A., Taati, B., & Mihailidis, A. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2389149 · Cited by 126
Use of High-Frequency In-Home Monitoring Data May Reduce Sample Sizes Needed in Clinical Trials
Dodge, H. H., Zhu, J., Mattek, N. C., Austin, D., Kornfeld, J., & Kaye, J. A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138095 · Cited by 99
Self-citationWu, C., Beattie, Z., Mattek, N., Sharma, N., Kaye, J., & Dodge, H. H. (2021) · Alzheimer's & Dementia: Translational Research & Clinical Interventions · doi:10.1002/trc2.12220 · Cited by 18
Self-citationHantke, N. C., Kaye, J., Mattek, N., Wu, C.-Y., Dodge, H. H., Beattie, Z., & Woltjer, R. (2023) · PLOS ONE · doi:10.1371/journal.pone.0286812 · Cited by 10
Self-citation
Metadata
- Authors
- Hagler, S., Austin, D., Hayes, T. L., Kaye, J., & Pavel, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2010-04
- Volume
- 57
- Issue
- 4
- Pages
- 813-820
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2121895804
- Cited by
- 169
- References
- 3
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.