Automatic Detection of Pathological Voices Using Complexity Measures, Noise Parameters, and Mel-Cepstral Coefficients
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
This paper proposes a new approach to improve the amount of information extracted from the speech aiming to increase the accuracy of a system developed for the automatic detection of pathological voices. The paper addresses the discrimination capabilities of 11 features extracted using nonlinear analysis of time series. Two of these features are based on conventional nonlinear statistics (largest Lyapunov exponent and correlation dimension), two are based on recurrence and fractal-scaling analysis, and the remaining are based on different estimations of the entropy. Moreover, this paper uses a strategy based on combining classifiers for fusing the nonlinear analysis with the information provided by classic parameterization approaches found in the literature (noise parameters and mel-frequency cepstral coefficients). The classification was carried out in two steps using, first, a generative and, later, a discriminative approach. Combining both classifiers, the best accuracy obtained is 98.23% ± 0.001.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A tutorial on hidden Markov models and selected applications in speech recognition
Rabiner, L. R. (1989) · Proceedings of the IEEE · doi:10.1109/5.18626 · Cited by 22,743 · cited 2×
“Denoting the actual state of the process in time t as St , a DHMM can be characterized by the following parameters [49]: 1) π = {πi}, i = 1, 2, .”
BackgroundMethodElements of Information Theory
Cover, T. M., & Thomas, J. A. (2005) · doi:10.1002/047174882x · Cited by 13,791
Determining Lyapunov exponents from a time series
Wolf, A., Swift, J. B., Swinney, H. L., & Vastano, J. A. (1985) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(85)90011-9 · Cited by 9,499
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880 · cited 4×
“The value of r was fixed to r = rc · std(signal), being std(·) the standard deviation operator [22].”
BackgroundMethodInfluentialApproximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811 · cited 2×
“However, in [18], Pincus demonstrated that there exist stochastic processes with CD equal to zero and, in general, it is not valid to infer the presence of an underlying deterministic system from the convergence of the algorithms designed to estimate these measures.”
BackgroundMultiscale entropy analysis of biological signals
Costa, M., Goldberger, A. L., & Peng, C.-K. (2005) · Physical Review E · doi:10.1103/physreve.71.021906 · Cited by 2,482
Ho, K. K. L., Moody, G. B., Peng, C.-K., Mietus, J. E., Larson, M. G., Levy, D., & Goldberger, A. L. (1997) · Circulation · doi:10.1161/01.cir.96.3.842 · Cited by 489 · cited 1×
“AE is a regularity statistic that quantifies the unpredictability of the fluctuations in a time series, and reflects the likelihood that similar patterns of observations will not be followed by additional similar observations [24].”
ResultGodino-Llorente, J. I., Gomez-Vilda, P., & Blanco-Velasco, M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.871883 · Cited by 322 · cited 2×
“These structures have been used independently for the detection of pathological voices, and have proven to be very reliable in comparison to others used in the state of the art [39].”
BackgroundMethodSelf-citationPathological assessment of patients’ speech signals using nonlinear dynamical analysis
Vaziri, G., Almasganj, F., & Behroozmand, R. (2010) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2009.10.011 · Cited by 88 · cited 3×
“These values were set after different experiments changing the values in the range [5, 10] and [16, 256], respectively.”
BackgroundMethod
Cited by
Detection of Pathological Voice Using Cepstrum Vectors: A Deep Learning Approach
Fang, S.-H., Tsao, Y., Hsiao, M.-J., Chen, J.-Y., Lai, Y.-H., Lin, F.-C., & Wang, C.-T. (2019) · Journal of Voice · doi:10.1016/j.jvoice.2018.02.003 · Cited by 278
Parkinson disease prediction using intrinsic mode function based features from speech signal
Karan, B., Sahu, S. S., & Mahto, K. (2020) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2019.05.005 · Cited by 165
The Effect of the MFCC Frame Length in Automatic Voice Pathology Detection
Tirronen, S., Kadiri, S. R., & Alku, P. (2024) · Journal of Voice · doi:10.1016/j.jvoice.2022.03.021 · Cited by 45
Detection of vocal disorders based on phase space parameters and Lyapunov spectrum
Ghasemzadeh, H., Tajik Khass, M., Khalil Arjmandi, M., & Pooyan, M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.07.002 · Cited by 40
Developing an Artificial Intelligence Tool to Predict Vocal Cord Pathology in Primary Care Settings
Compton, E. C., Cruz, T., Andreassen, M., Beveridge, S., Bosch, D., Randall, D. R., & Livingstone, D. (2023) · The Laryngoscope · doi:10.1002/lary.30432 · Cited by 38
Metadata
- Authors
- Arias-Londoño, J. D., Godino-Llorente, J. I., Sáenz-Lechón, N., Osma-Ruiz, V, & Castellanos-Domínguez, G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-02
- Volume
- 58
- Issue
- 2
- Pages
- 370-379
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2093862051
- Cited by
- 155
- References
- 9
- FWCI
- 6.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.