The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A Novel Method for Detection of the Transition Between Atrial Fibrillation and Sinus Rhythm
Abstract
Automatic detection of atrial fibrillation (AF) for AF diagnosis, especially for AF monitoring, is necessarily desirable for clinical therapy. In this study, we proposed a novel method for detection of the transition between AF and sinus rhythm based on RR intervals. First, we obtained the delta RR interval distribution difference curve from the density histogram of delta RR intervals, and then detected its peaks, which represented the AF events. Once an AF event was detected, four successive steps were used to classify its type, and thus, determine the boundary of AF: 1) histogram analysis; 2) standard deviation analysis; 3) numbering aberrant rhythms recognition; and 4) Kolmogorov-Smirnov (K-S) test. A dataset of 24-h Holter ECG recordings (n = 433) and two MIT-BIH databases (MIT-BIH AF database and MIT-BIH normal sinus rhythm (NSR) database) were used for development and evaluation. Using the receiver operating characteristic curves for determining the threshold of the K-S test, we have achieved the highest performance of sensitivity and specificity (SP) (96.1% and 98.1%, respectively) for the MIT-BIH AF database, compared with other previously published algorithms. The SP was 97.9% for the MIT-BIH NSR database.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Prevalence, incidence and lifetime risk of atrial fibrillation: the Rotterdam study
Heeringa, J., van der Kuip, D. A. M., Hofman, A., Kors, J. A., van Herpen, G., Stricker, B. H. C., Stijnen, T., Lip, G. Y. H., & Witteman, J. C. M. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi825 · Cited by 1,939
Population prevalence, incidence, and predictors of atrial fibrillation in the Renfrew/Paisley study
Stewart, S., Hart, C. L., Hole, D. J., & McMurray, J. J. V. (2001) · Heart · doi:10.1136/heart.86.5.516 · Cited by 661
Cited by
Detecting atrial fibrillation by deep convolutional neural networks
Xia, Y., Wulan, N., Wang, K., & Zhang, H. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.12.007 · Cited by 349
Fan, X., Yao, Q., Cai, Y., Miao, F., Sun, F., & Li, Y. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2858789 · Cited by 323
Faust, O., Shenfield, A., Kareem, M., San, T. R., Fujita, H., & Acharya, U. R. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.07.001 · Cited by 309
Metadata
- Authors
- Huang, C., Ye, S., Chen, H., Li, D., He, F., & Tu, Y.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-04
- Volume
- 58
- Issue
- 4
- Pages
- 1113-1119
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2170605288
- Cited by
- 185
- References
- 4
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Method for Detection of the Transition Between Atrial Fibrillation and Sinus Rhythm. https://app.cochat.ai/papers/10.1109/tbme.2010.2096506
- The paper
- Huang, C., Ye, S., Chen, H., Li, D., He, F., & Tu, Y. (2011). A Novel Method for Detection of the Transition Between Atrial Fibrillation and Sinus Rhythm. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2010.2096506
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.