Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 309

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Retinal Image Analysis Using Curvelet Transform and Multistructure Elements Morphology by Reconstruction

Miri, M S, Mahloojifar, A·2011·IEEE Transactions on Biomedical Engineering

Abstract

Retinal images can be used in several applications, such as ocular fundus operations as well as human recognition. Also, they play important roles in detection of some diseases in early stages, such as diabetes, which can be performed by comparison of the states of retinal blood vessels. Intrinsic characteristics of retinal images make the blood vessel detection process difficult. Here, we proposed a new algorithm to detect the retinal blood vessels effectively. Due to the high ability of the curvelet transform in representing the edges, modification of curvelet transform coefficients to enhance the retinal image edges better prepares the image for the segmentation part. The directionality feature of the multistructure elements method makes it an effective tool in edge detection. Hence, morphology operators using multistructure elements are applied to the enhanced image in order to find the retinal image ridges. Afterward, morphological operators by reconstruction eliminate the ridges not belonging to the vessel tree while trying to preserve the thin vessels unchanged. In order to increase the efficiency of the morphological operators by reconstruction, they were applied using multistructure elements. A simple thresholding method along with connected components analysis (CCA) indicates the remained ridges belonging to vessels. In order to utilize CCA more efficiently, we locally applied the CCA and length filtering instead of considering the whole image. Experimental results on a known database, DRIVE, and achieving to more than 94% accuracy in about 50 s for blood vessel detection, proved that the blood vessels can be effectively detected by applying our method on the retinal images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2010.2097599

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 309

Metadata

Authors
Miri, M. S., & Mahloojifar, A.
Venue
IEEE Transactions on Biomedical Engineering
Published
2011-05
Volume
58
Issue
5
Pages
1183-1192
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2105839704
Cited by
309
References
11
FWCI
6.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Retinal Image Analysis Using Curvelet Transform and Multistructure Elements Morphology by Reconstruction. https://app.cochat.ai/papers/10.1109/tbme.2010.2097599
The paper
Miri, M. S., & Mahloojifar, A. (2011). Retinal Image Analysis Using Curvelet Transform and Multistructure Elements Morphology by Reconstruction. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2010.2097599

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.