Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 424

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Optimizing the Channel Selection and Classification Accuracy in EEG-Based BCI

Arvaneh, Mahnaz, Guan, Cuntai, Ang, Kai Keng, Quek, Chai·2011·IEEE Transactions on Biomedical Engineering

Abstract

Multichannel EEG is generally used in brain-computer interfaces (BCIs), whereby performing EEG channel selection 1) improves BCI performance by removing irrelevant or noisy channels and 2) enhances user convenience from the use of lesser channels. This paper proposes a novel sparse common spatial pattern (SCSP) algorithm for EEG channel selection. The proposed SCSP algorithm is formulated as an optimization problem to select the least number of channels within a constraint of classification accuracy. As such, the proposed approach can be customized to yield the best classification accuracy by removing the noisy and irrelevant channels, or retain the least number of channels without compromising the classification accuracy obtained by using all the channels. The proposed SCSP algorithm is evaluated using two motor imagery datasets, one with a moderate number of channels and another with a large number of channels. In both datasets, the proposed SCSP channel selection significantly reduced the number of channels, and outperformed existing channel selection methods based on Fisher criterion, mutual information, support vector machine, common spatial pattern, and regularized common spatial pattern in classification accuracy. The proposed SCSP algorithm also yielded an average improvement of 10% in classification accuracy compared to the use of three channels (C3, C4, and Cz).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2011.2131142

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Research works printed but not linked: 4

  1. 10.1007/BFb0063615 · doi:10.1007/bfb0063615
  2. krauledat, 2007, Robustifying EEG data analysis by removing outliers, Chaos and Complexity Letters, 2, 259
  3. 10.1109/ICASSP.2008.4517635 · doi:10.1109/icassp.2008.4517635
  4. arvaneh, 2010, Optimizing EEG channel selection by regularized spatial filtering and multi band signal decomposition, Proc Int Assoc Sci Technol Develop Int Conf Biomed Eng, 86

Cited by

See all 424

Metadata

Authors
Arvaneh, M., Guan, C., Ang, K. K., & Quek, C.
Venue
IEEE Transactions on Biomedical Engineering
Published
2011-06
Volume
58
Issue
6
Pages
1865-1873
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2100409538
Cited by
424
References
30
FWCI
8.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimizing the Channel Selection and Classification Accuracy in EEG-Based BCI. https://app.cochat.ai/papers/10.1109/tbme.2011.2131142
The paper
Arvaneh, M., Guan, C., Ang, K. K., & Quek, C. (2011). Optimizing the Channel Selection and Classification Accuracy in EEG-Based BCI. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2011.2131142

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.