Assessment of Crohn’s Disease Lesions in Wireless Capsule Endoscopy Images
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Capsule endoscopy (CE) provides noninvasive access to a large part of the small bowel that is otherwise inaccessible without invasive and traumatic treatment. However, it also produces large amounts of data (approximately 50,000 images) that must be then manually reviewed by a clinician. Such large datasets provide an opportunity for application of image analysis and supervised learning methods. Automated analysis of CE images has only focused on detection, and often only for bleeding. Compared to these detection approaches, we explored assessment of discrete disease for lesions created by mucosal inflammation in Crohn's disease (CD). Our work is the first study to systematically explore supervised classification for CD lesions, a classifier cascade to classify discrete lesions, as well as quantitative assessment of lesion severity. We used a well-developed database of 47 studies for evaluation of these methods. The developed methods show high agreement with ground truth severity ratings manually assigned by an expert, and good precision ( > 90% for lesion detection) and recall ( > 90%) for lesions of varying severity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A performance evaluation of local descriptors
Mikolajczyk, K., & Schmid, C. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.188 · Cited by 6,723
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
A survey of content-based image retrieval with high-level semantics
Liu, Y., Zhang, D., Lu, G., & Ma, W.-Y. (2007) · Pattern Recognition · doi:10.1016/j.patcog.2006.04.045 · Cited by 1,696 · cited 1×
“In comparison to other content-based image retrieval [8] and conventional picture archiving and communication systems [9], only a few research systems [10]–[12] have investigated visual medical imaging such as conventional endoscopy, or CE images.”
Background
Cited by
Application of Artificial Intelligence to Gastroenterology and Hepatology
Le Berre, C., Sandborn, W. J., Aridhi, S., Devignes, M.-D., Fournier, L., Smaïl-Tabbone, M., Danese, S., & Peyrin-Biroulet, L. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.08.058 · Cited by 516
Big data in IBD: big progress for clinical practice
Seyed Tabib, N. S., Madgwick, M., Sudhakar, P., Verstockt, B., Korcsmaros, T., & Vermeire, S. (2020) · Gut · doi:10.1136/gutjnl-2019-320065 · Cited by 223
Gubatan, J., Levitte, S., Patel, A., Balabanis, T., Wei, M. T., & Sinha, S. R. (2021) · World Journal of Gastroenterology · doi:10.3748/wjg.v27.i17.1920 · Cited by 121
Christou, C. D., & Tsoulfas, G. (2021) · World Journal of Gastroenterology · doi:10.3748/wjg.v27.i37.6191 · Cited by 54
Metadata
- Authors
- Kumar, R., Zhao, Q., Seshamani, S., Mullin, G., Hager, G., & Dassopoulos, T.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-02
- Volume
- 59
- Issue
- 2
- Pages
- 355-362
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1981506718
- Cited by
- 87
- References
- 3
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.