The DOI matches its Crossref record.
Automated Segmentation of Intraretinal Cystoid Fluid in Optical Coherence Tomography
Open accessAbstract
Cystoid macular edema (CME) is observed in a variety of ocular disorders and is strongly associated with vision loss. Optical coherence tomography (OCT) provides excellent visualization of cystoid fluid, and can assist clinicians in monitoring the progression of CME. Quantitative tools for assessing CME may lead to better metrics for choosing treatment protocols. To address this need, this paper presents a fully automated retinal cyst segmentation technique for OCT image stacks acquired from a commercial scanner. The proposed method includes a computationally fast bilateral filter for speckle denoising while maintaining CME boundaries. The proposed technique was evaluated in images from 16 patients with vitreoretinal disease and three controls. The average sensitivity and specificity for the classification of cystoid regions in CME patients were found to be 91% and 96%, respectively, and the retinal volume occupied by cystoid fluid obtained by the algorithm was found to be accurate within a mean and median volume fraction of 1.9% and 0.8%, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fully Automated Detection and Quantification of Macular Fluid in OCT Using Deep Learning
Schlegl, T., Waldstein, S. M., Bogunovic, H., Endstraßer, F., Sadeghipour, A., Philip, A.-M., Podkowinski, D., Gerendas, B. S., Langs, G., & Schmidt-Erfurth, U. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.10.031 · Cited by 597
Retinal specialist versus artificial intelligence detection of retinal fluid from OCT
Keenan, T. D. L., Clemons, T. E., Domalpally, A., Elman, M. J., Havilio, M., Agrón, E., Benyamini, G., & Chew, E. Y. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.06.038 · Cited by 93
Metadata
- Authors
- Wilkins, G. R., Houghton, O. M., & Oldenburg, A. L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-04
- Volume
- 59
- Issue
- 4
- Pages
- 1109-1114
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2134542952
- Cited by
- 162
- References
- 0
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.