The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Fully Automated Detection and Quantification of Macular Fluid in OCT Using Deep Learning
Open accessAbstract
PURPOSE: Development and validation of a fully automated method to detect and quantify macular fluid in conventional OCT images. DESIGN: Development of a diagnostic modality. PARTICIPANTS: The clinical dataset for fluid detection consisted of 1200 OCT volumes of patients with neovascular age-related macular degeneration (AMD, n = 400), diabetic macular edema (DME, n = 400), or retinal vein occlusion (RVO, n = 400) acquired with Zeiss Cirrus (Carl Zeiss Meditec, Dublin, CA) (n = 600) or Heidelberg Spectralis (Heidelberg Engineering, Heidelberg, Germany) (n = 600) OCT devices. METHODS: A method based on deep learning to automatically detect and quantify intraretinal cystoid fluid (IRC) and subretinal fluid (SRF) was developed. The performance of the algorithm in accurately identifying fluid localization and extent was evaluated against a manual consensus reading of 2 masked reading center graders. MAIN OUTCOME MEASURES: Performance of a fully automated method to accurately detect, differentiate, and quantify intraretinal and SRF using area under the receiver operating characteristics curves, precision, and recall. RESULTS: The newly designed, fully automated diagnostic method based on deep learning achieved optimal accuracy for the detection and quantification of IRC for all 3 macular pathologies with a mean accuracy (AUC) of 0.94 (range, 0.91-0.97), a mean precision of 0.91, and a mean recall of 0.84. The detection and measurement of SRF were also highly accurate with an AUC of 0.92 (range, 0.86-0.98), a mean precision of 0.61, and a mean recall of 0.81, with superior performance in neovascular AMD and RVO compared with DME, which was represented rarely in the population studied. High linear correlation was confirmed between automated and manual fluid localization and quantification, yielding an average Pearson's correlation coefficient of 0.90 for IRC and of 0.96 for SRF. CONCLUSIONS: Deep learning in retinal image analysis achieves excellent accuracy for the differential detection of retinal fluid types across the most prevalent exudative macular diseases and OCT devices. Furthermore, quantification of fluid achieves a high level of concordance with manual expert assessment. Fully automated analysis of retinal OCT images from clinical routine provides a promising horizon in improving accuracy and reliability of retinal diagnosis for research and clinical practice in ophthalmology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Maguire, M. G., Martin, D. F., Ying, G.-S., Jaffe, G. J., Daniel, E., Grunwald, J. E., Toth, C. A., Ferris, F. L., & Fine, S. L. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.03.045 · Cited by 708
Elman, M. J., Ayala, A., Bressler, N. M., Browning, D., Flaxel, C. J., Glassman, A. R., Jampol, L. M., & Stone, T. W. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2014.08.047 · Cited by 562
A paradigm shift in imaging biomarkers in neovascular age-related macular degeneration
Schmidt-Erfurth, U., & Waldstein, S. M. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.007 · Cited by 390
Self-citationA Treat and Extend Regimen Using Ranibizumab for Neovascular Age-Related Macular Degeneration
Gupta, O. P., Shienbaum, G., Patel, A. H., Fecarotta, C., Kaiser, R. S., & Regillo, C. D. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.02.032 · Cited by 272
Sharma, S., Toth, C. A., Daniel, E., Grunwald, J. E., Maguire, M. G., Ying, G.-S., Huang, J., Martin, D. F., & Jaffe, G. J. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2015.12.002 · Cited by 231
Cited by
Clinically applicable deep learning for diagnosis and referral in retinal disease
De Fauw, J., Ledsam, J. R., Romera-Paredes, B., Nikolov, S., Tomasev, N., Blackwell, S., Askham, H., Glorot, X., O’Donoghue, B., Visentin, D., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0107-6 · Cited by 2,639
Liu, X., Faes, L., Kale, A. U., Wagner, S. K., Fu, D. J., Bruynseels, A., Mahendiran, T., Moraes, G., Shamdas, M., Kern, C., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30123-2 · Cited by 1,883
Artificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
f-AnoGAN: Fast unsupervised anomaly detection with generative adversarial networks
Schlegl, T., Seeböck, P., Waldstein, S. M., Langs, G., & Schmidt-Erfurth, U. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.01.010 · Cited by 1,545
Self-citationArtificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Metadata
- Authors
- Schlegl, T., Waldstein, S. M., Bogunovic, H., Endstraßer, F., Sadeghipour, A., Philip, A.-M., Podkowinski, D., Gerendas, B. S., Langs, G., & Schmidt-Erfurth, U.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2018-04
- Volume
- 125
- Issue
- 4
- Pages
- 549-558
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2772059204
- Cited by
- 597
- References
- 6
- FWCI
- 30.86
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully Automated Detection and Quantification of Macular Fluid in OCT Using Deep Learning. https://app.cochat.ai/papers/10.1016/j.ophtha.2017.10.031
- The paper
- Schlegl, T., Waldstein, S. M., Bogunovic, H., Endstraßer, F., Sadeghipour, A., Philip, A.-M., Podkowinski, D., Gerendas, B. S., Langs, G., & Schmidt-Erfurth, U. (2018). Fully Automated Detection and Quantification of Macular Fluid in OCT Using Deep Learning. Ophthalmology. https://doi.org/10.1016/j.ophtha.2017.10.031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.