The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
A Microphone Array System for Automatic Fall Detection
Abstract
More than a third of elderly fall each year in the United States. It has been shown that the longer the lie on the floor, the poorer is the outcome of the medical intervention. To reduce delay of the medical intervention, we have developed an acoustic fall detection system (acoustic-FADE) that automatically detects a fall and reports it promptly to the caregiver. Acoustic-FADE consists of a circular microphone array that captures the sounds in a room. When a sound is detected, acoustic-FADE locates the source, enhances the signal, and classifies it as "fall" or "nonfall." The sound source is located using the steered response power with phase transform technique, which has been shown to be robust under noisy environments and resilient to reverberation effects. Signal enhancement is performed by the beamforming technique based on the estimated sound source location. Height information is used to increase the specificity. The mel-frequency cepstral coefficient features computed from the enhanced signal are utilized in the classification process. We have evaluated the performance of acoustic-FADE using simulated fall and nonfall sounds performed by three stunt actors trained to behave like elderly under different environmental conditions. Using a dataset consisting of 120 falls and 120 nonfalls, the acoustic-FADE achieves 100% sensitivity at a specificity of 97%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398
Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine
Zweig, M. H., & Campbell, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.4.561 · Cited by 6,569
Optimum Array Processing: Part IV of Detection, Estimation, and Modulation Theory
Van Trees, H. L. (2002) · Wiley eBooks · doi:10.1002/0471221104 · Cited by 5,188
Geriatric Falls: Injury Severity Is High and Disproportionate to Mechanism
Sterling, D. A., O???Connor, J. A., & Bonadies, J. (2001) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200101000-00021 · Cited by 802
EARLY MORTALITY AFTER HIP FRACTURE: IS DELAY BEFORE SURGERY IMPORTANT?
MORAN, C. G., WENN, R. T., SIKAND, M., & TAYLOR, A. M. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200503000-00001 · Cited by 670
Fall detection - Principles and Methods
Noury, N., Fleury, A., Rumeau, P., Bourke, A. K., Laighin, G. O., Rialle, V., & Lundy, J. E. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352627 · Cited by 615
O’Shaughnessy, D. D. (1987) · Addison-Wesley Longman Publishing Co., Inc. eBooks · Cited by 452
(1922) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(22)90565-4 · Cited by 449
Speech communication, human and machine
Karjalainen, M. (1988) · Signal Processing · doi:10.1016/0165-1684(88)90074-6 · Cited by 410
A Smart and Passive Floor-Vibration Based Fall Detector for Elderly
Alwan, M., Rajendran, P. J., Kell, S., Mack, D., Dalal, S., Wolfe, M., & Felder, R. (2006) · 2006 2nd International Conference on Information & Communication Technologies · doi:10.1109/ictta.2006.1684511 · Cited by 402
Cited by
WiFall: Device-Free Fall Detection by Wireless Networks
Wang, Y., Wu, K., & Ni, L. M. (2017) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2016.2557792 · Cited by 836
Challenges, issues and trends in fall detection systems
Igual, R., Medrano, C., & Plaza, I. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-66 · Cited by 654
RT-Fall: A Real-Time and Contactless Fall Detection System with Commodity WiFi Devices
Wang, H., Zhang, D., Wang, Y., Ma, J., Wang, Y., & Li, S. (2017) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2016.2557795 · Cited by 640
Witrisal, K., Meissner, P., Leitinger, E., Shen, Y., Gustafson, C., Tufvesson, F., Haneda, K., Dardari, D., Molisch, A. F., Conti, A., et al. (2016) · IEEE Signal Processing Magazine · doi:10.1109/msp.2015.2504328 · Cited by 448
Internet-of-Things and Smart Homes for Elderly Healthcare: An End User Perspective
Pal, D., Funilkul, S., Charoenkitkarn, N., & Kanthamanon, P. (2018) · IEEE Access · doi:10.1109/access.2018.2808472 · Cited by 333
Yu, M., Rhuma, A., Naqvi, S. M., Wang, L., & Chambers, J. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2214786 · Cited by 316
Depth-Based Human Fall Detection via Shape Features and Improved Extreme Learning Machine
Ma, X., Wang, H., Xue, B., Zhou, M., Ji, B., & Li, Y. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2304357 · Cited by 286
Self-citationResearch of Fall Detection and Fall Prevention Technologies: A Systematic Review
Ren, L., & Peng, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2922708 · Cited by 266
Fall Detection Devices and Their Use With Older Adults: A Systematic Review
Chaudhuri, S., Thompson, H., & Demiris, G. (2014) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e3182abe779 · Cited by 215
Ambient Sensors for Elderly Care and Independent Living: A Survey
Uddin, M. Z., Khaksar, W., & Torresen, J. (2018) · Sensors · doi:10.3390/s18072027 · Cited by 166
Device-Free RF Human Body Fall Detection and Localization in Industrial Workplaces
Kianoush, S., Savazzi, S., Vicentini, F., Rampa, V., & Giussani, M. (2017) · IEEE Internet of Things Journal · doi:10.1109/jiot.2016.2624800 · Cited by 113
Utilising LiDAR for fall detection
Frøvik, N., Malekzai, B. A., & Øvsthus, K. (2021) · Healthcare Technology Letters · doi:10.1049/htl2.12001 · Cited by 19
Huang, M., & Garcia, A. (2023) · Applied Sciences · doi:10.3390/app132011379 · Cited by 9
Metadata
- Authors
- Li, Y., Ho, K. C., & Popescu, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-05
- Volume
- 59
- Issue
- 5
- Pages
- 1291-1301
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2028656089
- Cited by
- 309
- References
- 27
- FWCI
- 21.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.