The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
A Microphone Array System for Automatic Fall Detection
Abstract
More than a third of elderly fall each year in the United States. It has been shown that the longer the lie on the floor, the poorer is the outcome of the medical intervention. To reduce delay of the medical intervention, we have developed an acoustic fall detection system (acoustic-FADE) that automatically detects a fall and reports it promptly to the caregiver. Acoustic-FADE consists of a circular microphone array that captures the sounds in a room. When a sound is detected, acoustic-FADE locates the source, enhances the signal, and classifies it as "fall" or "nonfall." The sound source is located using the steered response power with phase transform technique, which has been shown to be robust under noisy environments and resilient to reverberation effects. Signal enhancement is performed by the beamforming technique based on the estimated sound source location. Height information is used to increase the specificity. The mel-frequency cepstral coefficient features computed from the enhanced signal are utilized in the classification process. We have evaluated the performance of acoustic-FADE using simulated fall and nonfall sounds performed by three stunt actors trained to behave like elderly under different environmental conditions. Using a dataset consisting of 120 falls and 120 nonfalls, the acoustic-FADE achieves 100% sensitivity at a specificity of 97%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398
Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine
Zweig, M. H., & Campbell, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.4.561 · Cited by 6,569
Optimum Array Processing: Part IV of Detection, Estimation, and Modulation Theory
Van Trees, H. L. (2002) · Wiley eBooks · doi:10.1002/0471221104 · Cited by 5,188
Geriatric Falls: Injury Severity Is High and Disproportionate to Mechanism
Sterling, D. A., O???Connor, J. A., & Bonadies, J. (2001) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200101000-00021 · Cited by 802
EARLY MORTALITY AFTER HIP FRACTURE: IS DELAY BEFORE SURGERY IMPORTANT?
MORAN, C. G., WENN, R. T., SIKAND, M., & TAYLOR, A. M. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200503000-00001 · Cited by 670
Fall detection - Principles and Methods
Noury, N., Fleury, A., Rumeau, P., Bourke, A. K., Laighin, G. O., Rialle, V., & Lundy, J. E. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352627 · Cited by 615
O’Shaughnessy, D. D. (1987) · Addison-Wesley Longman Publishing Co., Inc. eBooks · Cited by 452
(1922) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(22)90565-4 · Cited by 449
Speech communication, human and machine
Karjalainen, M. (1988) · Signal Processing · doi:10.1016/0165-1684(88)90074-6 · Cited by 410
A Smart and Passive Floor-Vibration Based Fall Detector for Elderly
Alwan, M., Rajendran, P. J., Kell, S., Mack, D., Dalal, S., Wolfe, M., & Felder, R. (2006) · 2006 2nd International Conference on Information & Communication Technologies · doi:10.1109/ictta.2006.1684511 · Cited by 402
Robust sound source localization using a microphone array on a mobile robot
Valin, J.-M., Michaud, F., Rouat, J., & Letourneau, D. (2004) · Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453) · doi:10.1109/iros.2003.1248813 · Cited by 381
Zigel, Y., Litvak, D., & Gannot*, I. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2030171 · Cited by 375
Fall Detection from Human Shape and Motion History Using Video Surveillance
Rougier, C., Meunier, J., St-Arnaud, A., & Rousseau, J. (2007) · 21st International Conference on Advanced Information Networking and Applications Workshops (AINAW'07) · doi:10.1109/ainaw.2007.181 · Cited by 324
Persons Found in Their Homes Helpless or Dead
Gurley, R. J., Lum, N., Sande, M., Lo, B., & Katz, M. H. (1996) · New England Journal of Medicine · doi:10.1056/nejm199606273342606 · Cited by 236
Portable preimpact fall detector with inertial sensors
Wu, G., & Xue, S. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916282 · Cited by 227
An acoustic fall detector system that uses sound height information to reduce the false alarm rate
Popescu, M., Li, Y., Skubic, M., & Rantz, M. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4650244 · Cited by 189
Self-citationA Generalized Steered Response Power Method for Computationally Viable Source Localization
Dmochowski, J. P., Benesty, J., & Affes, S. (2007) · IEEE Transactions on Audio, Speech and Language Processing · doi:10.1109/tasl.2007.906694 · Cited by 162
Fall detection of elderly through floor vibrations and sound
Litvak, D., Zigel, Y., & Gannot, I. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650245 · Cited by 98
Testing of a long-term fall detection system incorporated into a custom vest for the elderly
Bourke, A. K., van de Ven, P. W. J., Chaya, A. E., OLaighin, G. M., & Nelson, J. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649795 · Cited by 95
Acoustic fall detection using a circular microphone array
Li, Y., Zeng, Z., Popescu, M., & Ho, K. C. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627368 · Cited by 87
Self-citationAcoustic fall detection using one-class classifiers
Popescu, M., & Mahnot, A. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334521 · Cited by 81
Self-citationAn Automated Acoustic System to Monitor and Classify Birds
Kwan, C., Ho, K. C., Mei, G., et al. (2006) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/asp/2006/96706 · Cited by 69
Self-citationSound source localization for robot auditory systems
Cho, Y., Yook, D., Chang, S., et al. (2009) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2009.5278040 · Cited by 38
Design and test of a long-term fall detection system incorporated into a custom vest for the elderly
Bourke, A. K., van de Ven, P. W. J., Chaya, A. E., et al. (2008) · IET Irish Signals and Systems Conference (ISSC) · doi:10.1049/cp:20080680 · Cited by 33
Prado-Velasco, M., Cidoncha, M. G. D. R., & Ortíz‐Marín, R. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649918 · Cited by 24
Falls, Technology, and Stunt Actors
Rantz, M., Aud, M. A., Alexander, G. L., Wakefield, B. J., Skubic, M., Luke, R. H., Anderson, D. T., & Keller, J. M. (2008) · Journal of Nursing Care Quality · doi:10.1097/01.ncq.0000324581.59557.42 · Cited by 19
Improving acoustic fall recognition by adaptive signal windowing
Li, Y., Popescu, M., Ho, K. C., & Nabelek, D. P. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091871 · Cited by 10
Self-citation
Cited by
WiFall: Device-Free Fall Detection by Wireless Networks
Wang, Y., Wu, K., & Ni, L. M. (2017) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2016.2557792 · Cited by 836
Challenges, issues and trends in fall detection systems
Igual, R., Medrano, C., & Plaza, I. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-66 · Cited by 654
RT-Fall: A Real-Time and Contactless Fall Detection System with Commodity WiFi Devices
Wang, H., Zhang, D., Wang, Y., Ma, J., Wang, Y., & Li, S. (2017) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2016.2557795 · Cited by 640
Witrisal, K., Meissner, P., Leitinger, E., Shen, Y., Gustafson, C., Tufvesson, F., Haneda, K., Dardari, D., Molisch, A. F., Conti, A., et al. (2016) · IEEE Signal Processing Magazine · doi:10.1109/msp.2015.2504328 · Cited by 448
Internet-of-Things and Smart Homes for Elderly Healthcare: An End User Perspective
Pal, D., Funilkul, S., Charoenkitkarn, N., & Kanthamanon, P. (2018) · IEEE Access · doi:10.1109/access.2018.2808472 · Cited by 333
Metadata
- Authors
- Li, Y., Ho, K. C., & Popescu, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-05
- Volume
- 59
- Issue
- 5
- Pages
- 1291-1301
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2028656089
- Cited by
- 309
- References
- 27
- FWCI
- 21.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.