The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Intention-Based EMG Control for Powered Exoskeletons
Abstract
Electromyographical (EMG) signals have been frequently used to estimate human muscular torques. In the field of human-assistive robotics, these methods provide valuable information to provide effectively support to the user. However, their usability is strongly limited by the necessity of complex user-dependent and session-dependent calibration procedures, which confine their use to the laboratory environment. Nonetheless, an accurate estimate of muscle torque could be unnecessary to provide effective movement assistance to users. The natural ability of human central nervous system of adapting to external disturbances could compensate for a lower accuracy of the torque provided by the robot and maintain the movement accuracy unaltered, while the effort is reduced. In order to explore this possibility, in this paper we study the reaction of ten healthy subjects to the assistance provided through a proportional EMG control applied by an elbow powered exoskeleton. This system gives only a rough estimate of the user muscular torque but does not require any specific calibration. Experimental results clearly show that subjects adapt almost instantaneously to the assistance provided by the robot and can reduce their effort while keeping full control of the movement under different dynamic conditions (i.e., no alterations of movement accuracy are observed).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive representation of dynamics during learning of a motor task
Shadmehr, R., & Mussa-Ivaldi, F. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-05-03208.1994 · Cited by 2,612
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,772
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Buchanan, T. S., Lloyd, D. G., Manal, K., & Besier, T. F. (2004) · Journal of Applied Biomechanics · doi:10.1123/jab.20.4.367 · Cited by 941
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
The contractile properties of human motor units during voluntary isometric contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010087 · Cited by 476
Intention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474
The Computational Neurobiology of Reaching and Pointing: A Foundation for Motor Learning
Shadmehr, R., & Wise, S. P. (2004) · Cited by 437
A QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
Cited by
Ultraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024
A Review on Lower Limb Rehabilitation Exoskeleton Robots
Shi, D., Zhang, W., Zhang, W., & Ding, X. (2019) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-019-0389-8 · Cited by 508
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Personalizing exoskeleton assistance while walking in the real world
Slade, P., Kochenderfer, M. J., Delp, S. L., & Collins, S. H. (2022) · Nature · doi:10.1038/s41586-022-05191-1 · Cited by 328
Metadata
- Authors
- Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-08
- Volume
- 59
- Issue
- 8
- Pages
- 2180-2190
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2076024315
- Cited by
- 400
- References
- 56
- FWCI
- 11.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intention-Based EMG Control for Powered Exoskeletons. https://app.cochat.ai/papers/10.1109/tbme.2012.2198821
- The paper
- Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012). Intention-Based EMG Control for Powered Exoskeletons. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2012.2198821
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.