Cited by 1,170Prosthetics and Rehabilitation RoboticsRobotic Locomotion and ControlSoft Robotics and Applications

Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)

Zoss, A.B., Kazerooni, H., Chu, A.·2006·IEEE/ASME Transactions on Mechatronics

Abstract

Wheeled vehicles are often incapable of transporting heavy materials over rough terrain or up staircases. Lower extremity exoskeletons supplement human intelligence with the strength and endurance of a pair of wearable robotic legs that support a payload. This paper summarizes the design and analysis of the Berkeley lower extremity exoskeleton (BLEEX). The anthropomorphically based BLEEX has 7 DOF per leg, four of which are powered by linear hydraulic actuators. The selection of the DOF, critical hardware design aspects, and initial performance measurements of BLEEX are discussed.

Integrity signals

Registry

Crossref · 10.1109/tmech.2006.871087

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • BLEEX was developed to help soldiers carry heavy loads.

    “The Berkeley Lower Extremity Exoskeleton (BLEEX), shown in Figure 3A, was developed to help soldiers to carry heavy loads [20], [36].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zoss, A. B., Kazerooni, H., & Chu, A.
Affiliations
University of California, Berkeley (US)
Venue
IEEE/ASME Transactions on Mechatronics
Published
2006-04
Volume
11
Issue
2
Pages
128-138
ISSN
1083-4435 (ISSN-L)
OpenAlex
W2102046115
Cited by
1,170
References
20
Citations by year
2026: 20 · 2025: 39 · 2024: 47 · 2023: 65 · 2022: 92 · 2021: 88 · 2020: 88 · 2019: 98 · 2018: 83 · 2017: 96 · 2016: 96 · 2015: 73 · 2014: 68 · 2013: 55 · 2012: 53
FWCI
14.09
Type
journal article
Language
en
Open access
closed
Locations
IEEE/ASME Transactions on Mechatronics (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Robotic Locomotion and Control
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
Keywords
lower limb exoskeleton, biomechanical design, humanoid robots, degrees of freedom, hardware design, stair climbing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review