The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Atrial Fibrillation Detection Using an iPhone 4S
Abstract
Atrial fibrillation (AF) affects three to five million Americans and is associated with significant morbidity and mortality. Existing methods to diagnose this paroxysmal arrhythmia are cumbersome and/or expensive. We hypothesized that an iPhone 4S can be used to detect AF based on its ability to record a pulsatile photoplethysmogram signal from a fingertip using the built-in camera lens. To investigate the capability of the iPhone 4S for AF detection, we first used two databases, the MIT-BIH AF and normal sinus rhythm (NSR) to derive discriminatory threshold values between two rhythms. Both databases include RR time series originating from 250 Hz sampled ECG recordings. We rescaled the RR time series to 30 Hz so that the RR time series resolution is 1/30 (s) which is equivalent to the resolution from an iPhone 4S. We investigated three statistical methods consisting of the root mean square of successive differences (RMSSD), the Shannon entropy (ShE) and the sample entropy (SampE), which have been proved to be useful tools for AF assessment. Using 64-beat segments from the MIT-BIH databases, we found the beat-to-beat accuracy value of 0.9405, 0.9300, and 0.9614 for RMSSD, ShE, and SampE, respectively. Using an iPhone 4S, we collected 2-min pulsatile time series from 25 prospectively recruited subjects with AF pre- and postelectrical cardioversion. Using derived threshold values of RMSSD, ShE and SampE from the MIT-BIH databases, we found the beat-to-beat accuracy of 0.9844, 0.8494, and 0.9522, respectively. It should be recognized that for clinical applications, the most relevant objective is to detect the presence of AF in the data. Using this criterion, we achieved an accuracy of 100% for both the MIT-BIH AF and iPhone 4S databases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452
Self-citationNew-Onset Atrial Fibrillation: Sex Differences in Presentation, Treatment, and Outcome
Humphries, K. H., Kerr, C. R., Connolly, S. J., Klein, G., Boone, J. A., Green, M., Sheldon, R., Talajic, M., Dorian, P., & Newman, D. (2001) · Circulation · doi:10.1161/01.cir.103.19.2365 · Cited by 378 · cited 1×
“Although the population burden of known AF is substantial, [5] studies have shown that more frequent monitoring can improve AF detection [6].”
Background
Cited by
The Internet of Things for Health Care: A Comprehensive Survey
Riazul Islam, S. M., Kwak, D., Humaun Kabir, M., Hossain, M., & Kwak, K.-S. (2015) · IEEE Access · doi:10.1109/access.2015.2437951 · Cited by 3,095
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
A deep learning approach for real-time detection of atrial fibrillation
Andersen, R. S., Peimankar, A., & Puthusserypady, S. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2018.08.011 · Cited by 402
Detecting atrial fibrillation by deep convolutional neural networks
Xia, Y., Wulan, N., Wang, K., & Zhang, H. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.12.007 · Cited by 349
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
Metadata
- Authors
- Lee, J., Reyes, B. A., McManus, D. D., Maitas, O., & Chon, K. H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-01
- Volume
- 60
- Issue
- 1
- Pages
- 203-206
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1982692087
- Cited by
- 238
- References
- 3
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atrial Fibrillation Detection Using an iPhone 4S. https://app.cochat.ai/papers/10.1109/tbme.2012.2208112
- The paper
- Lee, J., Reyes, B. A., McManus, D. D., Maitas, O., & Chon, K. H. (2013). Atrial Fibrillation Detection Using an iPhone 4S. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2012.2208112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.