Physiological parameter monitoring from optical recordings with a mobile phone
Open accessAbstract
We show that a mobile phone can serve as an accurate monitor for several physiological variables, based on its ability to record and analyze the varying color signals of a fingertip placed in contact with its optical sensor. We confirm the accuracy of measurements of breathing rate, cardiac R-R intervals, and blood oxygen saturation, by comparisons to standard methods for making such measurements (respiration belts, ECGs, and pulse-oximeters, respectively). Measurement of respiratory rate uses a previously reported algorithm developed for use with a pulse-oximeter, based on amplitude and frequency modulation sequences within the light signal. We note that this technology can also be used with recently developed algorithms for detection of atrial fibrillation or blood loss.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Papers that have developed health monitoring systems have mostly used their own data gathering experiments to design, model and test the data analysis step.
“The papers which have developed the health monitoring systems have mostly used their own data gathering experiments to design, model and test the data analysis step [26,38,88].”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [88]
Some research has been done on unlabeled data to consider uncontrolled situations, especially for experimental data sets.
“Some researches have been done on unlabeled data in order to consider uncontrolled situations for especially experimental data sets [39,44,88].”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [88]
Monitoring cardiorespiratory activities using a PPG signal is a well-established non-invasive technique.
“Monitoring cardiorespiratory activities using a PPG signal is a well-established non-invasive technique [44,93].”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [93]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,728 · see citing works
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M., McDuff, D., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,652 · see citing works
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M., McDuff, D., & Picard, R. W. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,488 · see citing works
Boulos, M. N. K., Wheeler, S., Tavares, C., & Jones, R. B. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-24 · Cited by 1,071 · see citing works
Pulse Oximetry: Theory and Applications for Noninvasive Monitoring
Mendelson, Y. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1601 · Cited by 320 · see citing works
Self-citationAutomatic Real Time Detection of Atrial Fibrillation
Dash, S. S., Chon, K. H., Lu, S., & Raeder, E. A. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9740-z · Cited by 314 · see citing works
Self-citationLu, S. F., Zhao, H., Ju, K., Shin, K., Lee, M., Shelley, K. H., & Chon, K. H. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9103-y · Cited by 284 · see citing works
Self-citationAssessment of cardiovascular autonomic function
Freeman, R. L. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.09.027 · Cited by 262 · see citing works
Estimation of Respiratory Rate From Photoplethysmogram Data Using Time–Frequency Spectral Estimation
Chon, K. H., Dash, S., & Ju, K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2019766 · Cited by 213 · see citing works
Self-citationThe advantages of wearable green reflected photoplethysmography
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9506-z · Cited by 209 · see citing works
Investigating a smartphone imaging unit for photoplethysmography
Jonathan, E., & Leahy, M. J. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/11/n01 · Cited by 178 · see citing works
A novel method to detect Heart Beat Rate using a mobile phone
Pelegris, P., Banitsas, K. A., Orbach, T., & Kostas Marias, A. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626580 · Cited by 126 · see citing works
Cellular phone‐based photoplethysmographic imaging
Jonathan, E., & Leahy, M. J. (2010) · Journal of Biophotonics · doi:10.1002/jbio.201000050 · Cited by 118 · see citing works
An overview of recent health care support systems for eEmergency and mHealth applications
Kyriacou, E. C., Pattichis, C. S., & Pattichis, M. S. (2009) · doi:10.1109/iembs.2009.5333913 · Cited by 55 · see citing works
Selvaraj, N., Shelley, K. H., Silverman, D. G., et al. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2144981 · Cited by 34 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375 · see citing works
Banaee, H., Ahmed, M., & Loutfi, A. (2013) · Sensors · doi:10.3390/s131217472 · Cited by 452 · see citing works
Chan, P., Wong, C., Poh, Y. C., Pun, L., Leung, W. W., Wong, Y., Wong, M. M., Poh, M., Chu, D. W., & Siu, C. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.116.003428 · Cited by 240 · see citing works
PULSE‐SMART: Pulse‐Based Arrhythmia Discrimination Using a Novel Smartphone Application
McMANUS, D. D., CHONG, J. W., SONI, A., SACZYNSKI, J. S., ESA, N., NAPOLITANO, C., DARLING, C. E., BOYER, E., ROSEN, R. K., FLOYD, K. C., et al. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12842 · Cited by 156 · see citing works
Self-citationChoi, A., & Shin, H. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa5efa · Cited by 116 · see citing works
The Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103 · see citing works
“Monitoring cardiorespiratory activities using a PPG signal is a well-established non-invasive technique [44,93].”
MethodRemote PPG based vital sign measurement using adaptive facial regions
Tasli, H. E., Gudi, A., & den Uyl, M. (2014) · 2014 IEEE International Conference on Image Processing (ICIP) · doi:10.1109/icip.2014.7025282 · Cited by 99 · see citing works
Smart-watches: a potential challenger to the implantable loop recorder?
Carpenter, A., & Frontera, A. (2016) · Europace · doi:10.1093/europace/euv427 · Cited by 86 · see citing works
Bruining, N., Caiani, E., Chronaki, C., Guzik, P., & van der Velde, E. (2014) · European Journal of Preventive Cardiology · doi:10.1177/2047487314552604 · Cited by 81 · see citing works
Personalized Human Activity Recognition Based on Integrated Wearable Sensor and Transfer Learning
Fu, Z., He, X., Wang, E., Huo, J., Huang, J., & Wu, D. (2021) · Sensors · doi:10.3390/s21030885 · Cited by 79 · see citing works
Jacobson, N. C., Chow, S.-M., & Newman, M. G. (2019) · Behavior Research Methods · doi:10.3758/s13428-018-1101-0 · Cited by 63 · see citing works
Allado, E., Poussel, M., Moussu, A., Saunier, V., Bernard, Y., Albuisson, E., & Chenuel, B. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-047896 · Cited by 22 · see citing works
- Authors
- Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H.
- Affiliations
- Worcester Polytechnic Institute (US)
- National Institutes of Health (US)
- Corresponding author
- Chon, K. H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-02
- Volume
- 59
- Issue
- 2
- Pages
- 303-306
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- PMC
- PMC3476722
- OpenAlex
- W2060642847
- Cited by
- 452
- References
- 15
- Citations by year
- 2026: 5 · 2025: 15 · 2024: 19 · 2023: 23 · 2022: 28 · 2021: 26 · 2020: 31 · 2019: 32 · 2018: 38 · 2017: 38 · 2016: 37 · 2015: 57 · 2014: 44 · 2013: 36 · 2012: 22
- FWCI
- 19.29
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Institute of Biomedical Imaging and Bioengineering (ZICEB000059, ZICEB000077)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- smartphone sensing, fingertip photoplethysmography, physiological monitoring, respiratory rate estimation, RR interval, oxygen saturation, pulse oximetry, atrial fibrillation detection
- MeSH terms
- Algorithms, Heart Rate, Humans, Monitoring, Physiologic, Oximetry, Signal Processing, Computer-Assisted, Cell Phone, Respiratory Rate, Remote Sensing Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review