Cited by 452Non-Invasive Vital Sign MonitoringECG Monitoring and AnalysisHeart Rate Variability and Autonomic Control

Physiological parameter monitoring from optical recordings with a mobile phone

Open access
Scully, C. G., Jinseok Lee, Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., Chon, K. H.·2012·IEEE Transactions on Biomedical Engineering

Abstract

We show that a mobile phone can serve as an accurate monitor for several physiological variables, based on its ability to record and analyze the varying color signals of a fingertip placed in contact with its optical sensor. We confirm the accuracy of measurements of breathing rate, cardiac R-R intervals, and blood oxygen saturation, by comparisons to standard methods for making such measurements (respiration belts, ECGs, and pulse-oximeters, respectively). Measurement of respiratory rate uses a previously reported algorithm developed for use with a pulse-oximeter, based on amplitude and frequency modulation sequences within the light signal. We note that this technology can also be used with recently developed algorithms for detection of atrial fibrillation or blood loss.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2011.2163157

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H.
Affiliations
  • Worcester Polytechnic Institute (US)
  • National Institutes of Health (US)
Corresponding author
Chon, K. H.
Venue
IEEE Transactions on Biomedical Engineering
Published
2012-02
Volume
59
Issue
2
Pages
303-306
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2060642847
Cited by
452
References
15
Citations by year
2026: 5 · 2025: 15 · 2024: 19 · 2023: 23 · 2022: 28 · 2021: 26 · 2020: 31 · 2019: 32 · 2018: 38 · 2017: 38 · 2016: 37 · 2015: 57 · 2014: 44 · 2013: 36 · 2012: 22
FWCI
19.29
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health
  • National Institute of Biomedical Imaging and Bioengineering (ZICEB000059, ZICEB000077)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
smartphone sensing, fingertip photoplethysmography, physiological monitoring, respiratory rate estimation, RR interval, oxygen saturation, pulse oximetry, atrial fibrillation detection
MeSH terms
Algorithms, Heart Rate, Humans, Monitoring, Physiologic, Oximetry, Signal Processing, Computer-Assisted, Cell Phone, Respiratory Rate, Remote Sensing Technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review