The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Predicting Epileptic Seizures in Scalp EEG Based on a Variational Bayesian Gaussian Mixture Model of Zero-Crossing Intervals
Abstract
A novel patient-specific seizure prediction method based on the analysis of positive zero-crossing intervals in scalp electroencephalogram (EEG) is proposed. In a moving-window analysis, the histogram of these intervals for the current EEG epoch is computed, and the values corresponding to specific bins are selected as an observation. Then, the set of observations from the last 5 min is compared with two reference sets of data points (preictal and interictal) through novel measures of similarity and dissimilarity based on a variational Bayesian Gaussian mixture model of the data. A combined index is then computed and compared with a patient-specific threshold, resulting in a cumulative measure which is utilized to form an alarm sequence for each channel. Finally, this channel-based information is used to generate a seizure prediction alarm. The proposed method was evaluated using ∼ 561 h of scalp EEG including a total of 86 seizures in 20 patients. A high sensitivity of 88.34 % was achieved with a false prediction rate of 0.155 h⁻¹ and an average prediction time of 22.5 min for the test dataset. The proposed method was also tested against a Poisson-based random predictor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
The Kolmogorov-Smirnov Test for Goodness of Fit
Massey, F. J. (1951) · Journal of the American Statistical Association · doi:10.1080/01621459.1951.10500769 · Cited by 7,210
Cited by
Tsiouris, Κ. Μ., Pezoulas, V. C., Zervakis, M., Konitsiotis, S., Koutsouris, D. D., & Fotiadis, D. I. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.019 · Cited by 632
Efficient Epileptic Seizure Prediction Based on Deep Learning
Daoud, H., & Bayoumi, M. A. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2929053 · Cited by 483
Machine Learning for Predicting Epileptic Seizures Using EEG Signals: A Review
Rasheed, K., Qayyum, A., Qadir, J., Sivathamboo, S., Kwan, P., Kuhlmann, L., O'Brien, T., & Razi, A. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.3008792 · Cited by 409
Epilepsy Seizure Prediction on EEG Using Common Spatial Pattern and Convolutional Neural Network
Zhang, Y., Guo, Y., Yang, P., Chen, W., & Lo, B. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2933046 · Cited by 319
EEG seizure detection and prediction algorithms: a survey
Alotaiby, T. N., Alshebeili, S. A., Alshawi, T., Ahmad, I., & Abd El-Samie, F. E. (2014) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/1687-6180-2014-183 · Cited by 292
Metadata
- Authors
- Shahidi Zandi, A., Tafreshi, R., Javidan, M., & Dumont, G. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-05
- Volume
- 60
- Issue
- 5
- Pages
- 1401-1413
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2152282628
- Cited by
- 177
- References
- 2
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Predicting Epileptic Seizures in Scalp EEG Based on a Variational Bayesian Gaussian Mixture Model of Zero-Crossing Intervals. https://app.cochat.ai/papers/10.1109/tbme.2012.2237399
- The paper
- Shahidi Zandi, A., Tafreshi, R., Javidan, M., & Dumont, G. A. (2013). Predicting Epileptic Seizures in Scalp EEG Based on a Variational Bayesian Gaussian Mixture Model of Zero-Crossing Intervals. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2012.2237399
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.